Genaro Rico-Martínez
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Genaro Rico-Martínez has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Arturo Vera
Electrical Engineering Department, Bioelectronics Section, Center for Research and Advanced Studies of the National Polytechnic Institute CINVESTAV-IPN, Mexico City 07360, Mexico
3 shared publications - Citlalli Jessica Trujillo-Romero
Instituto Nacional de Rehabilitación-LGII
3 shared publications - Josefina Gutiérrez-Martínez
Instituto Nacional de Rehabilitación
3 shared publications - Lorenzo Leija
Centro de Investigación y de Estudios Avanzados del IPN, Av. Instituto Politécnico Nacional 2508, San Pedro Zacatenco, G.A.M., Mexico City 07360, Mexico
3 shared publications - Raquel Martínez-Valdez
Autonomous University of Aguascalientes,Department of Biomedical Engineering,Aguascalientes,Mexico
2 shared publications - Texar Javier Ramírez-Guzmán
Electrical Engineering Department, Bioelectronics Section, CINVESTAV-IPN, Instituto Politécnico Nacional 2508, San Pedro Zacatenco, Mexico City 07360, Mexico
2 shared publications
Latest Publications
- Open Access
Thermal Evaluation of Multi-Antenna Systems Proposed to Treat Bone Tumors: Finite Element Analysis
Microwave ablation is commonly used in soft tissue tumors, but its application in bone tumors has been barely analyzed. Antennas to treat bone tissue (~3 cm2), has been lately designed. Bone tumors at pathological stage T1 can reach 8 cm wide. An antenna cannot cover it; therefore, our goal is to evaluate the thermal performance of multi-antenna arrays. Linear, triangular, and square configurations of double slot (DS) and monopole (MTM) antennas were evaluated. A parametric study (finite element method), with variations in distance between antennas (ad) and bone thickness (bt) was implemented. Array feasibility was evaluated by SWR, ablated tissue volume, etc. The linear configuration with DS and MTM antennas showed SWR ≤ 1.6 for ad = 1 mm–15 mm and bt = 20 mm–40 mm, and ad = 10 mm–15 mm and bt = 25 mm–40 mm, respectively; the triangular showed SWR ≤ 1.5 for ad = 5 mm–15 mm and bt = 20 mm–40 mm and ad = 10 mm–15 mm and bt = 25 mm–40 mm. The square configuration (DS) generated SWR ≤ 1.5 for ad = 5 mm–20 mm and bt = 20 mm–40 mm, and the MTM, SWR ≤ 1.5 with ad = 10 mm and bt = 25 mm–40 mm. Ablated tissue was 4.65 cm3–10.46 cm3 after 5 min. According to treatment time and array configuration, maximum temperature and ablated tissue is modified. Bone tumors >3 cm3 can be treated by these antenna-arrays.
Open AccessThermal Evaluation of Multi-Antenna Systems Proposed to Treat Bone Tumors: Finite Element Analysis
Microwave ablation is commonly used in soft tissue tumors, but its application in bone tumors has been barely analyzed. Antennas to treat bone tissue (~3 cm2), has been lately designed. Bone tumors at pathological stage T1 can reach 8 cm wide. An antenna cannot cover it; therefore, our goal is to evaluate the thermal performance of multi-antenna arrays. Linear, triangular, and square configurations of double slot (DS) and monopole (MTM) antennas were evaluated. A parametric study (finite element method), with variations in distance between antennas (ad) and bone thickness (bt) was implemented. Array feasibility was evaluated by SWR, ablated tissue volume, etc. The linear configuration with DS and MTM antennas showed SWR ≤ 1.6 for ad = 1 mm–15 mm and bt = 20 mm–40 mm, and ad = 10 mm–15 mm and bt = 25 mm–40 mm, respectively; the triangular showed SWR ≤ 1.5 for ad = 5 mm–15 mm and bt = 20 mm–40 mm and ad = 10 mm–15 mm and bt = 25 mm–40 mm. The square configuration (DS) generated SWR ≤ 1.5 for ad = 5 mm–20 mm and bt = 20 mm–40 mm, and the MTM, SWR ≤ 1.5 with ad = 10 mm and bt = 25 mm–40 mm. Ablated tissue was 4.65 cm3–10.46 cm3 after 5 min. According to treatment time and array configuration, maximum temperature and ablated tissue is modified. Bone tumors >3 cm3 can be treated by these antenna-arrays.
- Open Access
- 17 September 2021
- Published by MDPI AG in Electronics
- Vol. 10 (18) , 2289
Thermal Evaluation of a Micro-Coaxial Antenna Set to Treat Bone Tumors: Design, Parametric FEM Modeling and Evaluation in Multilayer Phantom and Ex Vivo Porcine Tissue
Bone cancer is rare in adults, the most affected persons by this disease are young people and children. The common treatments for bone cancer are surgery, chemotherapy, and targeted therapies; however, all of them have side-effects that decrease the patient’s quality of life. Thermotherapy is one of the most promising treatments for bone cancer; its main goal is to increase the tumor temperature to kill cancerous cells. Although some micro-coaxial antennas have been used to treat bone tumors, most of them are designed to treat soft tissue. Therefore, the purpose of this work is to analyze the thermal behavior of four micro-coaxial antennas specifically designed to generate thermal ablation in bone tissue to treat bone tumors, at 2.45 GHz. The proposed antennas were the metal-tip monopole (MTM), the choked metal-tip monopole (CMTM), the double slot (DS) and the choked double slot (CDS). The design and optimization of the antennas by using the Finite Element Method (FEM) allow to predict the optimal antenna dimensions and their performance when they are in contact with the affected biological tissues (bone, muscle, and fat). In the FEM model, a maximum power transmission was selected as the main parameter to choose the optimum antenna design, i.e., a Standing Wave Ratio (SWR) value around 1.2–1.5. The four optimized antennas were constructed and experimentally evaluated. The evaluation was carried out in multilayer phantoms (fat, muscle, cortical, and cancellous bone) and ex vivo porcine tissue at different insertion depths of the antennas. To fully evaluate the antennas performance, the standing wave ratio (SWR), power loss, temperature profiles, and thermal distributions were analyzed. In the experimentation, the four antennas were able to reach ablation temperatures (>60 °C) and the highest reached SWR was 1.7; the MTM (power loss around 16%) and the CDS (power loss around 6.4%) antennas presented the lowest SWR values depending on the antenna insertion depth, either in multilayer tissue phantom or in ex vivo tissue. These proposed antennas allow to obtain ablation temperatures with an input power of 5 W after 5 min of treatment; these values are lower than the ones reported in the literature.
- 17 September 2021
- Published by MDPI AG in Electronics
- Vol. 10 (18) , 2289
Open AccessThermal Evaluation of a Micro-Coaxial Antenna Set to Treat Bone Tumors: Design, Parametric FEM Modeling and Evaluation in Multilayer Phantom and Ex Vivo Porcine Tissue
Bone cancer is rare in adults, the most affected persons by this disease are young people and children. The common treatments for bone cancer are surgery, chemotherapy, and targeted therapies; however, all of them have side-effects that decrease the patient’s quality of life. Thermotherapy is one of the most promising treatments for bone cancer; its main goal is to increase the tumor temperature to kill cancerous cells. Although some micro-coaxial antennas have been used to treat bone tumors, most of them are designed to treat soft tissue. Therefore, the purpose of this work is to analyze the thermal behavior of four micro-coaxial antennas specifically designed to generate thermal ablation in bone tissue to treat bone tumors, at 2.45 GHz. The proposed antennas were the metal-tip monopole (MTM), the choked metal-tip monopole (CMTM), the double slot (DS) and the choked double slot (CDS). The design and optimization of the antennas by using the Finite Element Method (FEM) allow to predict the optimal antenna dimensions and their performance when they are in contact with the affected biological tissues (bone, muscle, and fat). In the FEM model, a maximum power transmission was selected as the main parameter to choose the optimum antenna design, i.e., a Standing Wave Ratio (SWR) value around 1.2–1.5. The four optimized antennas were constructed and experimentally evaluated. The evaluation was carried out in multilayer phantoms (fat, muscle, cortical, and cancellous bone) and ex vivo porcine tissue at different insertion depths of the antennas. To fully evaluate the antennas performance, the standing wave ratio (SWR), power loss, temperature profiles, and thermal distributions were analyzed. In the experimentation, the four antennas were able to reach ablation temperatures (>60 °C) and the highest reached SWR was 1.7; the MTM (power loss around 16%) and the CDS (power loss around 6.4%) antennas presented the lowest SWR values depending on the antenna insertion depth, either in multilayer tissue phantom or in ex vivo tissue. These proposed antennas allow to obtain ablation temperatures with an input power of 5 W after 5 min of treatment; these values are lower than the ones reported in the literature.
- Open Access
- 24 March 2021
- Published by MDPI AG in Electronics
- Vol. 10 (7) , 761
Double Slot Antenna for Microwave Thermal Ablation to Treat Bone Tumors: Modeling and Experimental Evaluation
According to statistics of the American Cancer Society, the number of young people diagnosed with bone tumors is growing. Surgery and radiotherapy are the common treatments, however they have several side effects which affect the patient’s life. Therefore, a cheaper and less side-effect therapy called thermal ablation has been explored. The goal of this paper is to measure the therapeutic temperatures and the viability of a double slot antenna designed to treat bone tissue by microwave ablation. The antenna (at an operating frequency of 2.45 GHz) was designed, modeled, constructed, and experimentally evaluated. The finite element method was used to predict the antenna performance by means of 2D axisymmetric models. The modeling parameters were used to build the antenna. The experimental evaluation shows that the antenna behavior is repeatable and the standing wave ratio (SWR) was around 1.5–1.8. Temperatures around 60–100 °C were achieved over the bone tissue. The antenna insertion modifies the antenna performance. An insertion lower than 3.5 cm is not recommended because the convection effects modified the tissue temperature. The thermal patterns showed a heat focus near to the slots, which makes it possible for use in the treatment of small tumors.
- 24 March 2021
- Published by MDPI AG in Electronics
- Vol. 10 (7) , 761
Open AccessDouble Slot Antenna for Microwave Thermal Ablation to Treat Bone Tumors: Modeling and Experimental Evaluation
According to statistics of the American Cancer Society, the number of young people diagnosed with bone tumors is growing. Surgery and radiotherapy are the common treatments, however they have several side effects which affect the patient’s life. Therefore, a cheaper and less side-effect therapy called thermal ablation has been explored. The goal of this paper is to measure the therapeutic temperatures and the viability of a double slot antenna designed to treat bone tissue by microwave ablation. The antenna (at an operating frequency of 2.45 GHz) was designed, modeled, constructed, and experimentally evaluated. The finite element method was used to predict the antenna performance by means of 2D axisymmetric models. The modeling parameters were used to build the antenna. The experimental evaluation shows that the antenna behavior is repeatable and the standing wave ratio (SWR) was around 1.5–1.8. Temperatures around 60–100 °C were achieved over the bone tissue. The antenna insertion modifies the antenna performance. An insertion lower than 3.5 cm is not recommended because the convection effects modified the tissue temperature. The thermal patterns showed a heat focus near to the slots, which makes it possible for use in the treatment of small tumors.
- Open Access
- 23 March 2012
- Published by Springer Nature in Clinical Sarcoma Research
- Vol. 2 (1) , 9
Serum tumor markers in pediatric osteosarcoma: a summary review
Osteosarcoma is the most common primary high-grade bone tumor in both adolescents and children. Early tumor detection is key to ensuring effective treatment. Serum marker discovery and validation for pediatric osteosarcoma has accelerated in recent years, coincident with an evolving understanding of molecules and their complex interactions, and the compelling need for improved pediatric osteosarcoma outcome measures in clinical trials. This review gives a short overview of serological markers for pediatric osteosarcoma, and highlights advances in pediatric osteosarcoma-related marker research within the past year. Studies in the past year involving serum markers in patients with pediatric osteosarcoma can be assigned to one of four categories, i.e., new approaches and new markers, exploratory studies in specialized disease subsets, large cross-sectional validation studies, and longitudinal studies, with and without an intervention.
- 23 March 2012
- Published by Springer Nature in Clinical Sarcoma Research
- Vol. 2 (1) , 9
Open AccessSerum tumor markers in pediatric osteosarcoma: a summary review
Osteosarcoma is the most common primary high-grade bone tumor in both adolescents and children. Early tumor detection is key to ensuring effective treatment. Serum marker discovery and validation for pediatric osteosarcoma has accelerated in recent years, coincident with an evolving understanding of molecules and their complex interactions, and the compelling need for improved pediatric osteosarcoma outcome measures in clinical trials. This review gives a short overview of serological markers for pediatric osteosarcoma, and highlights advances in pediatric osteosarcoma-related marker research within the past year. Studies in the past year involving serum markers in patients with pediatric osteosarcoma can be assigned to one of four categories, i.e., new approaches and new markers, exploratory studies in specialized disease subsets, large cross-sectional validation studies, and longitudinal studies, with and without an intervention.