Hisanori Ariga
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Hisanori Ariga has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Ikuko Uwano
Iwate Medical University
1 shared publication - Koyo Kikuchi
Department of Radiation Oncology, Iwate Medical University School of Medicine , 2-1-1 Idaidori, Yahaba-cho, Shiwa-gun, Iwate 028-3695
1 shared publication - Ryuji Nakamura
Department of Radiology, Iwate Medical University, Morioka, Japan
1 shared publication - Satoshi Yamaguchi
Department of Radiology, School of Medicine, Iwate Medical University 1 , 2-1-1 Idaidori, Yahaba, Iwate 028-3695, Japan
1 shared publication - Susumu Tanji
Department of Urology, Iwate Medical University School of Medicine, Uchimaru 19-1, Morioka, 020-8505, Japan
1 shared publication - Tomoaki Fujioka
Department of Urology, Iwate Medical University School of Medicine, 19-1 Uchimaru, Morioka 020-8505, Japan
1 shared publication
Latest Publications
- Open Access
- 31 January 2012
- Published by Springer Nature in Radiation Oncology
- Vol. 7 (1) , 15
Narrow safety range of intraoperative rectal irradiation exposure volume for avoiding bleeding after seed implant brachytherapy
Rectal toxicity is less common after 125I seed implant brachytherapy for prostate cancer, and intraoperative rectal dose-volume constraints (the constraint) is still undetermined in pioneering studies. As our constraint failed to prevent grade 2 or 3 rectal bleeding (bled-pts) in 5.1% of patients, we retrospectively explored another constraint for the prevention of rectal bleeding. The study population consisted of 197 patients treated with the brachytherapy as monotherapy using real-time intraoperative transrectal ultrasound (US)-guided treatment at a prescribed dose of 145 Gy. Post-implant dosimetry was performed on Day 1 and Day 30 after implantation using computed tomography (CT) imaging. Rectal bleeding toxicity was classified by CTC-AE ver. 3.0 during a mean 29-month (range, 12-48 months) period after implantation. The differences in rV100s were compared among intraoperative, Day 1 and Day 30 dosimetry, and between that of patients with grade 2 or 3 rectal bleeding (the bled-pts) and of the others (the spared-pts). All patients were divided into groups based on provisional rV100s that were increased stepwise in 0.1-cc increments from 0 to 1.0 cc. The difference in the ratios of the bled-pts to the spared-pts was tested by chi-square tests, and their odds ratios were calculated (bled-OR). All statistical analyses were performed by t-tests. The mean values of rV100us, rV100CT_1, and rV100CT_30 were 0.31 ± 0.43, 0.22 ± 0.36, and 0.59 ± 0.68 cc, respectively. These values temporarily decreased (p = 0.020) on Day 1 and increased (p = 0.000) on Day 30. There was no significant difference in rV100s between the bled-pts and spared-pts at any time of dosimetry. The maximum bled-OR was identified among patients with an rV100us value above 0.1 cc (p = 0.025; OR = 7.8; 95% CI, 1.4-145.8); an rV100CT_1 value above 0.3 cc (p = 0.014; OR = 16.2; 95% CI, 3.9-110.7), and an rV100CT_30 value above 0.5 cc (p = 0.019; OR = 6.3; 95% CI, 1.5-42.3). By retrospective analysis exploring rV100 as intraoperative rectal dose-volume thresholds in 125I seed implant brachytherapy for prostate cancer, it is proved that rV100 should be less than 0.1 cc for preventing rectal bleeding.
- 31 January 2012
- Published by Springer Nature in Radiation Oncology
- Vol. 7 (1) , 15
Open AccessNarrow safety range of intraoperative rectal irradiation exposure volume for avoiding bleeding after seed implant brachytherapy
Rectal toxicity is less common after 125I seed implant brachytherapy for prostate cancer, and intraoperative rectal dose-volume constraints (the constraint) is still undetermined in pioneering studies. As our constraint failed to prevent grade 2 or 3 rectal bleeding (bled-pts) in 5.1% of patients, we retrospectively explored another constraint for the prevention of rectal bleeding. The study population consisted of 197 patients treated with the brachytherapy as monotherapy using real-time intraoperative transrectal ultrasound (US)-guided treatment at a prescribed dose of 145 Gy. Post-implant dosimetry was performed on Day 1 and Day 30 after implantation using computed tomography (CT) imaging. Rectal bleeding toxicity was classified by CTC-AE ver. 3.0 during a mean 29-month (range, 12-48 months) period after implantation. The differences in rV100s were compared among intraoperative, Day 1 and Day 30 dosimetry, and between that of patients with grade 2 or 3 rectal bleeding (the bled-pts) and of the others (the spared-pts). All patients were divided into groups based on provisional rV100s that were increased stepwise in 0.1-cc increments from 0 to 1.0 cc. The difference in the ratios of the bled-pts to the spared-pts was tested by chi-square tests, and their odds ratios were calculated (bled-OR). All statistical analyses were performed by t-tests. The mean values of rV100us, rV100CT_1, and rV100CT_30 were 0.31 ± 0.43, 0.22 ± 0.36, and 0.59 ± 0.68 cc, respectively. These values temporarily decreased (p = 0.020) on Day 1 and increased (p = 0.000) on Day 30. There was no significant difference in rV100s between the bled-pts and spared-pts at any time of dosimetry. The maximum bled-OR was identified among patients with an rV100us value above 0.1 cc (p = 0.025; OR = 7.8; 95% CI, 1.4-145.8); an rV100CT_1 value above 0.3 cc (p = 0.014; OR = 16.2; 95% CI, 3.9-110.7), and an rV100CT_30 value above 0.5 cc (p = 0.019; OR = 6.3; 95% CI, 1.5-42.3). By retrospective analysis exploring rV100 as intraoperative rectal dose-volume thresholds in 125I seed implant brachytherapy for prostate cancer, it is proved that rV100 should be less than 0.1 cc for preventing rectal bleeding.