M. L. Dewal
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
M. L. Dewal has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- H. S. Bhadauria
Department of Computer Science and Engineering, GBPIET, Pauri, India
2 shared publications - R. S. Anand
Indian Institute of Technology Roorkee
2 shared publications - Kalpana Chauhan
Central University of Haryana
1 shared publication - Manoj Kumar Rohit
Departments of Cardiology, Advanced Cardiac Centre, Postgraduate Institute of Medical Education and Research, Chandigarh, India
1 shared publication - Tirupathiraju Kanumuri
National Institute of Technology Delhi
1 shared publication - Yatindra Kumar
Department of Electrical Engineering, Indian Institute of Technology, Roorkee, India
1 shared publication
Latest Publications
- 10 August 2012
- Published by Springer Nature in Signal, Image and Video Processing
- Vol. 8 (7) , 1323-1334
Epileptic seizures detection in EEG using DWT-based ApEn and artificial neural network
- 10 August 2012
- Published by Springer Nature in Signal, Image and Video Processing
- Vol. 8 (7) , 1323-1334
Epileptic seizures detection in EEG using DWT-based ApEn and artificial neural network
- 15 May 2012
- Published by Springer Nature in Signal, Image and Video Processing
- Vol. 8 (5) , 883-899
Progressive medical image coding using binary wavelet transforms
- 15 May 2012
- Published by Springer Nature in Signal, Image and Video Processing
- Vol. 8 (5) , 883-899
Progressive medical image coding using binary wavelet transforms
- 23 March 2012
- Published by Springer Nature in Signal, Image and Video Processing
- Vol. 8 (2) , 357-364
Intracranial hemorrhage detection using spatial fuzzy c-mean and region-based active contour on brain CT imaging
- 23 March 2012
- Published by Springer Nature in Signal, Image and Video Processing
- Vol. 8 (2) , 357-364
Intracranial hemorrhage detection using spatial fuzzy c-mean and region-based active contour on brain CT imaging
- 25 January 2012
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 25 (6) , 782-791
Efficient Denoising Technique for CT images to Enhance Brain Hemorrhage Segmentation
This paper presents an adaptive denoising approach aiming to improve the visibility and detectability of hemorrhage from brain computed tomography (CT) images. The suggested approach fuses the images denoised by total variation (TV) method, denoised by curvelet-based method, and edge information extracted from the noise residue of TV method. The edge information is extracted from the noise residue of TV method by processing it through curvelet transform. The visual interpretation shows that the proposed approach not only reduces the staircase effect caused by total variation method but also reduces visual distortion induced by curvelet transform in the homogeneous areas of the CT images. The denoising abilities of the proposed method are further evaluated by segmenting the hemorrhagic brain area using region-growing method. The sensitivity, specificity, Jaccard index, and Dice coefficients were calculated for different noise levels. The comparative results show that the significant improvement has yielded in the brain hemorrhage detection from CT images after denoising it with the proposed approach.
- 25 January 2012
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 25 (6) , 782-791
Efficient Denoising Technique for CT images to Enhance Brain Hemorrhage Segmentation
This paper presents an adaptive denoising approach aiming to improve the visibility and detectability of hemorrhage from brain computed tomography (CT) images. The suggested approach fuses the images denoised by total variation (TV) method, denoised by curvelet-based method, and edge information extracted from the noise residue of TV method. The edge information is extracted from the noise residue of TV method by processing it through curvelet transform. The visual interpretation shows that the proposed approach not only reduces the staircase effect caused by total variation method but also reduces visual distortion induced by curvelet transform in the homogeneous areas of the CT images. The denoising abilities of the proposed method are further evaluated by segmenting the hemorrhagic brain area using region-growing method. The sensitivity, specificity, Jaccard index, and Dice coefficients were calculated for different noise levels. The comparative results show that the significant improvement has yielded in the brain hemorrhage detection from CT images after denoising it with the proposed approach.
- 21 July 2011
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 25 (2) , 271-278
A Fast Region-Based Active Contour Model for Boundary Detection of Echocardiographic Images
This paper presents the boundary detection of atrium and ventricle in echocardiographic images. In case of mitral regurgitation, atrium and ventricle may get dilated. To examine this, doctors draw the boundary manually. Here the aim of this paper is to evolve the automatic boundary detection for carrying out segmentation of echocardiography images. Active contour method is selected for this purpose. There is an enhancement of Chan–Vese paper on active contours without edges. Our algorithm is based on Chan–Vese paper active contours without edges, but it is much faster than Chan–Vese model. Here we have developed a method by which it is possible to detect much faster the echocardiographic boundaries. The method is based on the region information of an image. The region-based force provides a global segmentation with variational flow robust to noise. Implementation is based on level set theory so it easy to deal with topological changes. In this paper, Newton–Raphson method is used which makes possible the fast boundary detection.
- 21 July 2011
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 25 (2) , 271-278
A Fast Region-Based Active Contour Model for Boundary Detection of Echocardiographic Images
This paper presents the boundary detection of atrium and ventricle in echocardiographic images. In case of mitral regurgitation, atrium and ventricle may get dilated. To examine this, doctors draw the boundary manually. Here the aim of this paper is to evolve the automatic boundary detection for carrying out segmentation of echocardiography images. Active contour method is selected for this purpose. There is an enhancement of Chan–Vese paper on active contours without edges. Our algorithm is based on Chan–Vese paper active contours without edges, but it is much faster than Chan–Vese model. Here we have developed a method by which it is possible to detect much faster the echocardiographic boundaries. The method is based on the region information of an image. The region-based force provides a global segmentation with variational flow robust to noise. Implementation is based on level set theory so it easy to deal with topological changes. In this paper, Newton–Raphson method is used which makes possible the fast boundary detection.