J. Lipor
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
J. Lipor has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Barry D. Van Veen
Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, WI, USA
1 shared publication - Hyong Lee
Google Inc. Mountain View, USA
1 shared publication - Michael H. Kohrman
Department of Pediatrics, Comer Children's Hospital, University of Chicago, Chicago, Illinois 60637, USA
1 shared publication - P. Rana
Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, WI 53715, USA
1 shared publication - Wim van Drongelen
Department of Pediatrics, University of Chicago, Chicago, IL, USA
1 shared publication
Latest Publications
- 1 April 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 59 (4) , 1125-1134
Seizure Detection Using the Phase-Slope Index and Multichannel ECoG
Detection and analysis of epileptic seizures is of clinical and research interest. We propose a novel seizure detection and analysis scheme based on the phase-slope index (PSI) of directed influence applied to multichannel electrocorticogram data. The PSI metric identifies increases in the spatio-temporal interactions between channels that clearly distinguish seizure from interictal activity. We form a global metric of interaction between channels and compare this metric to a threshold to detect the presence of seizures. The threshold is chosen based on a moving average of recent activity to accommodate differences between patients and slow changes within each patient over time. We evaluate detection performance over a challenging population of five patients with different types of epilepsy using a total of 47 seizures in nearly 258 h of recorded data. Using a common threshold procedure, we show that our approach detects all of the seizures in four of the five patients with a false detection rate less than two per hour. A variation on the global metric is proposed to identify which channels are strong drivers of activity in each patient. These metrics are computationally efficient and suitable for real-time application.
- 1 April 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 59 (4) , 1125-1134
Seizure Detection Using the Phase-Slope Index and Multichannel ECoG
Detection and analysis of epileptic seizures is of clinical and research interest. We propose a novel seizure detection and analysis scheme based on the phase-slope index (PSI) of directed influence applied to multichannel electrocorticogram data. The PSI metric identifies increases in the spatio-temporal interactions between channels that clearly distinguish seizure from interictal activity. We form a global metric of interaction between channels and compare this metric to a threshold to detect the presence of seizures. The threshold is chosen based on a moving average of recent activity to accommodate differences between patients and slow changes within each patient over time. We evaluate detection performance over a challenging population of five patients with different types of epilepsy using a total of 47 seizures in nearly 258 h of recorded data. Using a common threshold procedure, we show that our approach detects all of the seizures in four of the five patients with a false detection rate less than two per hour. A variation on the global metric is proposed to identify which channels are strong drivers of activity in each patient. These metrics are computationally efficient and suitable for real-time application.