Xixia Ding
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Xixia Ding has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Xiao-Yan Che
Laboratory of Emerging Infectious Diseases and Division of Laboratory Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou, 510282, China; Department of Pediatrics, Zhujiang Hospital, Southern Medical University, Guangdong, China
3 shared publications - Yu-Xian Pan
Microbiome Medicine Center, State Key Laboratory of Organ Failure Research, Division of Laboratory Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou, People's Republic of China
3 shared publications - Dongmei Hu
Department of Obstetrics and Gynecology, Zhujiang Hospital, Southern Medical University, Guangzhou, China
2 shared publications - Nan Yu
Microbiome Medicine Center, Department of Laboratory Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou, Guangdong, People’s Republic of China
2 shared publications - Wei Hao
Laboratory of Emerging Infectious Diseases and Division of Laboratory Medicine, Zhujiang Hospital, Southern Medical University, No. 253 Gong-ye Avenue, Guangzhou, 510282, PR China
2 shared publications - Ya-Di Wang
Center for Clinical Laboratory, Zhujiang Hospital, Southern Medical University, No. 253 Gong ye da dao zhong, Guangzhou, Guangdong 510282, PR China
2 shared publications
Latest Publications
- 1 November 2015
- Published by Elsevier in Diagnostic Microbiology and Infectious Disease
- Vol. 83 (3) , 325-330
A comparison of Luminex xTAG® Gastrointestinal Pathogen Panel (xTAG GPP) and routine tests for the detection of enteropathogens circulating in Southern China
- 1 November 2015
- Published by Elsevier in Diagnostic Microbiology and Infectious Disease
- Vol. 83 (3) , 325-330
A comparison of Luminex xTAG® Gastrointestinal Pathogen Panel (xTAG GPP) and routine tests for the detection of enteropathogens circulating in Southern China
- Open Access
- 31 July 2013
- Published by MDPI AG in Biosensors
- Vol. 3 (3) , 297-311
Comparison of Surface Plasmon Resonance, Resonant Waveguide Grating Biosensing and Enzyme Linked Immunosorbent Assay (ELISA) in the Evaluation of a Dengue Virus Immunoassay
Two label-free biosensor platforms, Resonance Waveguide Grating (RWG) and Surface Plasmon Resonance (SPR), were used to rank a large panel of anti-dengue virus NS1 antibodies. Dengue non-structural 1 (NS1) protein is an established serological marker for the early detection of dengue infection. A variety of commercial dengue NS1 antigen capture immunoassays are available in both ELISA and lateral flow format. However, there is a significant scope to improve both the sensitivity and the specificity of those tests. The interactions of antibody (Ab)-antigen (Ag) were profiled, with weak interactions (KD = 1–0.1 μM) able to be detected under static equilibrium conditions by RWG, but not observed to under more rigorous flow conditions using SPR. There were significant differences in the absolute affinities determined by the two technologies, and there was a poor correlation between antibodies best ranked by RWG and the lower limit of detection (LLOD) found by ELISA. Hence, whilst high-throughput RWG can be useful as preliminary screening for higher affinity antibodies, care should be exercised in the assignation of quantitative values for affinity between different assay formats.
- 31 July 2013
- Published by MDPI AG in Biosensors
- Vol. 3 (3) , 297-311
Open AccessComparison of Surface Plasmon Resonance, Resonant Waveguide Grating Biosensing and Enzyme Linked Immunosorbent Assay (ELISA) in the Evaluation of a Dengue Virus Immunoassay
Two label-free biosensor platforms, Resonance Waveguide Grating (RWG) and Surface Plasmon Resonance (SPR), were used to rank a large panel of anti-dengue virus NS1 antibodies. Dengue non-structural 1 (NS1) protein is an established serological marker for the early detection of dengue infection. A variety of commercial dengue NS1 antigen capture immunoassays are available in both ELISA and lateral flow format. However, there is a significant scope to improve both the sensitivity and the specificity of those tests. The interactions of antibody (Ab)-antigen (Ag) were profiled, with weak interactions (KD = 1–0.1 μM) able to be detected under static equilibrium conditions by RWG, but not observed to under more rigorous flow conditions using SPR. There were significant differences in the absolute affinities determined by the two technologies, and there was a poor correlation between antibodies best ranked by RWG and the lower limit of detection (LLOD) found by ELISA. Hence, whilst high-throughput RWG can be useful as preliminary screening for higher affinity antibodies, care should be exercised in the assignation of quantitative values for affinity between different assay formats.
- Open Access
- 11 January 2012
- Published by Springer Nature in Virology Journal
- Vol. 9 (1) , 12
Evaluation of human enterovirus 71 and coxsackievirus A16 specific immunoglobulin M antibodies for diagnosis of hand-foot-and-mouth disease
Hand-foot-and-mouth disease (HFMD) is caused mainly by the human enterovirus type 71 (HEV71) and the Coxsackievirus A group type 16 (CVA16). Large outbreaks of disease have occurred frequently in the Asia-Pacific region. Reliable methods are needed for diagnosis of HFMD in childen. IgM-capture ELISA, with its notable advantages of convenience and low cost, provides a potentially frontline assay. We aimed to evaluate the newly developed IgM-capture ELISAs for HEV71 and CVA16 in the diagnosis of HFMD, and to measure the kinetics of IgM over the course of HEV71 or CVA16 infections.
- 11 January 2012
- Published by Springer Nature in Virology Journal
- Vol. 9 (1) , 12
Open AccessEvaluation of human enterovirus 71 and coxsackievirus A16 specific immunoglobulin M antibodies for diagnosis of hand-foot-and-mouth disease
Hand-foot-and-mouth disease (HFMD) is caused mainly by the human enterovirus type 71 (HEV71) and the Coxsackievirus A group type 16 (CVA16). Large outbreaks of disease have occurred frequently in the Asia-Pacific region. Reliable methods are needed for diagnosis of HFMD in childen. IgM-capture ELISA, with its notable advantages of convenience and low cost, provides a potentially frontline assay. We aimed to evaluate the newly developed IgM-capture ELISAs for HEV71 and CVA16 in the diagnosis of HFMD, and to measure the kinetics of IgM over the course of HEV71 or CVA16 infections.
- Open Access
- 2 February 2011
- Published by Springer Nature in Virology Journal
- Vol. 8 (1) , 47
Kinetics of non-structural protein 1, IgM and IgG antibodies in dengue type 1 primary infection
Background: Early and accurate diagnosis of dengue infection is essential for control of disease outbreaks. Recently, the dengue virus non-structural antigen 1 (NS1), a conserved and secreted glycoprotein, has been used as a marker for early diagnosis of dengue with convenience and cost-effectiveness. Serological tests of dengue IgM and IgG antibodies are still the most widely used for diagnosis of dengue. In order to assess combined diagnostic value of these tests, we study the kinetic profiles of circulating NS1, dengue IgM and IgG antibodies over the course of the disease by using an in-house dengue type 1 (DENV1) specific NS1 capture ELISA and the commercial Panbio Dengue IgM and IgG capture ELISAs. Results: A panel of 313 acute-and early convalescent-phase serum specimens from 140 DENV1 primary infected patients during an outbreak of dengue in Guangzhou, China, in 2006 were studied. Dengue NS1 presented high levels in acute-phase serum samples. It was detectable as early as day 1 of illness, and up to 14 day after onset. The sensitivity of NS1 detection was ranged from 81.8% to 91.1% with samples taken during the first 7 days. Anti-dengue IgM antibody was detectable on the third day of onset with the positive rate of 42.9%, and rapidly increasing to 100% by day 8 of illness. Anti-dengue IgG antibody was detectable on the fifth day of onset with low level at the first week of onset, and slowly increasing to 100% by day 15 of illness. Combining the results of NS1 and IgM antibody detection allowed positive diagnosis in 96.9% -100% for samples taken after day 3 of onset. Conclusions: Dengue NS1 detection might shorten the window period by first few days of illness. A combination of dengue NS1 antigen and IgM antibody testing facilitates enhanced diagnosis rates. The procedures should be suitable for developing countries where dengue is endemic.
- 2 February 2011
- Published by Springer Nature in Virology Journal
- Vol. 8 (1) , 47
Open AccessKinetics of non-structural protein 1, IgM and IgG antibodies in dengue type 1 primary infection
Background: Early and accurate diagnosis of dengue infection is essential for control of disease outbreaks. Recently, the dengue virus non-structural antigen 1 (NS1), a conserved and secreted glycoprotein, has been used as a marker for early diagnosis of dengue with convenience and cost-effectiveness. Serological tests of dengue IgM and IgG antibodies are still the most widely used for diagnosis of dengue. In order to assess combined diagnostic value of these tests, we study the kinetic profiles of circulating NS1, dengue IgM and IgG antibodies over the course of the disease by using an in-house dengue type 1 (DENV1) specific NS1 capture ELISA and the commercial Panbio Dengue IgM and IgG capture ELISAs. Results: A panel of 313 acute-and early convalescent-phase serum specimens from 140 DENV1 primary infected patients during an outbreak of dengue in Guangzhou, China, in 2006 were studied. Dengue NS1 presented high levels in acute-phase serum samples. It was detectable as early as day 1 of illness, and up to 14 day after onset. The sensitivity of NS1 detection was ranged from 81.8% to 91.1% with samples taken during the first 7 days. Anti-dengue IgM antibody was detectable on the third day of onset with the positive rate of 42.9%, and rapidly increasing to 100% by day 8 of illness. Anti-dengue IgG antibody was detectable on the fifth day of onset with low level at the first week of onset, and slowly increasing to 100% by day 15 of illness. Combining the results of NS1 and IgM antibody detection allowed positive diagnosis in 96.9% -100% for samples taken after day 3 of onset. Conclusions: Dengue NS1 detection might shorten the window period by first few days of illness. A combination of dengue NS1 antigen and IgM antibody testing facilitates enhanced diagnosis rates. The procedures should be suitable for developing countries where dengue is endemic.