Xinkun Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xinkun Li has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
DeChun LIANG
1 shared publicationFeiFei WANG
1 shared publication- Heng Wei
Key Laboratory of Semiconductor Materials Science, Institute of Semiconductors, Chinese Academy of Sciences, Beijing, 100083, China
1 shared publication - Jian Wu
Key Laboratory of Semiconductor Materials Science, Institute of Semiconductors, Chinese Academy of Sciences, Beijing, 100083, China
1 shared publication - Jianjun Li
Beijing Key Laboratory of Quantum Sensing and Precision Measurement, and Center for Quantum Information Technology, and Institute of Quantum Electronics, Peking University, Beijing 100871, China
1 shared publication - Jie Cao
Northeast Electric Power University
1 shared publication
Latest Publications
- Open Access
Fiber-Coupled Fully Integrated Spin-Exchange Relaxation-Free Atomic Magnetometer for Functional Biomagnetic Measurements
The atomic magnetometer (AM), operating within the spin-exchange relaxation-free (SERF) regime, boasts numerous advantageous qualities, including ultrahigh sensitivity, exceptional spatial resolution, and minimal power consumption. Consequently, it emerges as a promising alternative to superconducting quantum interference devices in biomagnetic measurement applications. This paper details the development of a fully integrated SERF AM system comprising a compact sensor head and corresponding control electronics. Utilizing a 4 mm × 4 mm × 4 mm cubic vapor cell, we have successfully integrated the compact sensor into a 9 volume employing a single-beam scheme facilitated by a polarization-maintaining fiber. The in-house control electronics encompass essential components, such as the laser driver, coil driver, vapor-cell temperature controller, and transimpedance amplifier. As a result, the fully integrated SERF AM achieves a sensitivity of 25 @5∼100 Hz, accompanied by a bandwidth of 193 Hz, meeting the necessary criteria for magnetocardiography (MCG) and magnetoencephalography (MEG) measurements. Furthermore, the fully integrated SERF AM successfully records typical MCG and alpha rhythm MEG signals, showcasing immense potential for biomagnetic imaging applications.Open AccessFiber-Coupled Fully Integrated Spin-Exchange Relaxation-Free Atomic Magnetometer for Functional Biomagnetic Measurements
The atomic magnetometer (AM), operating within the spin-exchange relaxation-free (SERF) regime, boasts numerous advantageous qualities, including ultrahigh sensitivity, exceptional spatial resolution, and minimal power consumption. Consequently, it emerges as a promising alternative to superconducting quantum interference devices in biomagnetic measurement applications. This paper details the development of a fully integrated SERF AM system comprising a compact sensor head and corresponding control electronics. Utilizing a 4 mm × 4 mm × 4 mm cubic vapor cell, we have successfully integrated the compact sensor into a 9 volume employing a single-beam scheme facilitated by a polarization-maintaining fiber. The in-house control electronics encompass essential components, such as the laser driver, coil driver, vapor-cell temperature controller, and transimpedance amplifier. As a result, the fully integrated SERF AM achieves a sensitivity of 25 @5∼100 Hz, accompanied by a bandwidth of 193 Hz, meeting the necessary criteria for magnetocardiography (MCG) and magnetoencephalography (MEG) measurements. Furthermore, the fully integrated SERF AM successfully records typical MCG and alpha rhythm MEG signals, showcasing immense potential for biomagnetic imaging applications. - Open Access
- 23 July 2025
- Published by MDPI AG in Electronics
- Vol. 14 (15) , 2932
Research of 110 kV High-Voltage Measurement Method Based on Rydberg Atoms
Accurate measurement of high voltages is required to guarantee the safe and stable operation of power systems. Modern power systems, which are mainly based on new energy sources, require high-voltage measurement instruments and equipment with characteristics such as high accuracy, wide frequency bandwidth, broad operating ranges, and ease of operation and maintenance. However, it is difficult for traditional electromagnetic measurement transformers to meet these requirements. To address the limitations of conventional Rydberg atomic measurement methods in low-frequency applications, this paper proposes an enhanced Rydberg measurement approach featuring high sensitivity and strong traceability, thereby enabling the application of Rydberg-based measurement methodologies under power frequency conditions. In this paper, a 110 kV high-voltage measurement method based on Rydberg atoms is studied. A power-frequency electric field measurement device is designed using Rydberg atoms, and its internal electric field distribution is analyzed. Additionally, a decoupling method is proposed to facilitate voltage measurements under multi-phase overhead lines in field conditions. The feasibility of the proposed method is confirmed, providing support for the future development of practical measurement devices.
- 23 July 2025
- Published by MDPI AG in Electronics
- Vol. 14 (15) , 2932
Open AccessResearch of 110 kV High-Voltage Measurement Method Based on Rydberg Atoms
Accurate measurement of high voltages is required to guarantee the safe and stable operation of power systems. Modern power systems, which are mainly based on new energy sources, require high-voltage measurement instruments and equipment with characteristics such as high accuracy, wide frequency bandwidth, broad operating ranges, and ease of operation and maintenance. However, it is difficult for traditional electromagnetic measurement transformers to meet these requirements. To address the limitations of conventional Rydberg atomic measurement methods in low-frequency applications, this paper proposes an enhanced Rydberg measurement approach featuring high sensitivity and strong traceability, thereby enabling the application of Rydberg-based measurement methodologies under power frequency conditions. In this paper, a 110 kV high-voltage measurement method based on Rydberg atoms is studied. A power-frequency electric field measurement device is designed using Rydberg atoms, and its internal electric field distribution is analyzed. Additionally, a decoupling method is proposed to facilitate voltage measurements under multi-phase overhead lines in field conditions. The feasibility of the proposed method is confirmed, providing support for the future development of practical measurement devices.
- 1 May 2015
- Published by Science China Press., Co. Ltd. in SCIENTIA SINICA Informationis
- Vol. 45 (5) , 693-700
芯片级铷原子气室的制备
- 1 May 2015
- Published by Science China Press., Co. Ltd. in SCIENTIA SINICA Informationis
- Vol. 45 (5) , 693-700
芯片级铷原子气室的制备
- Open Access
- 12 December 2011
- Published by Springer Nature in Discover Nano
- Vol. 6 (1) , 625
A high-performance quantum dot superluminescent diode with a two-section structure
Based on InAs/GaAs quantum dots [QDs], a high-power and broadband superluminescent diode [SLD] is achieved by monolithically integrating a conventional SLD with a semiconductor optical amplifier. The two-section QD-SLD device exhibits a high output power above 500 mW with a broad emission spectrum of 86 nm. By properly controlling the current injection in the two sections of the QD-SLD device, the output power of the SLD can be tuned over a wide range from 200 to 500 mW while preserving a broad emission spectrum based on the balance between the ground state emission and the first excited state emission of QDs. The gain process of the two-section QD-SLD with different pumping levels in the two sections is investigated.
- 12 December 2011
- Published by Springer Nature in Discover Nano
- Vol. 6 (1) , 625
Open AccessA high-performance quantum dot superluminescent diode with a two-section structure
Based on InAs/GaAs quantum dots [QDs], a high-power and broadband superluminescent diode [SLD] is achieved by monolithically integrating a conventional SLD with a semiconductor optical amplifier. The two-section QD-SLD device exhibits a high output power above 500 mW with a broad emission spectrum of 86 nm. By properly controlling the current injection in the two sections of the QD-SLD device, the output power of the SLD can be tuned over a wide range from 200 to 500 mW while preserving a broad emission spectrum based on the balance between the ground state emission and the first excited state emission of QDs. The gain process of the two-section QD-SLD with different pumping levels in the two sections is investigated.