Marlon Schwarz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Marlon Schwarz has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Christian Stoppe
Department of Anesthesiology, Intensive Care, Emergency and Pain Medicine, University Hospital Würzburg, Würzburg, Germany
1 shared publication - Gereon Schälte
Department of Anaesthesiology, Medical Faculty Aachen, Rhenish Westphalian Technical University (RWTH), Aachen, Germany
1 shared publication - Mark Coburn
Department of Anesthesiology and Intensive Care Medicine, University Hospital Bonn, Bonn, Germany
1 shared publication - Meral Aktas
Department of Pediatrics and Neonatology, University Hospital Aachen, Aachen, Germany
1 shared publication - Norbert Zoremba
Department of Anesthesiology, University Hospital Aachen, Aachen, Germany
1 shared publication - Rolf Rossaint
Department of Anesthesiology, Medical Faculty, University Hospital RWTH Aachen University, Aachen, Germany
1 shared publication
Latest Publications
- Open Access
- 1 January 2011
- Published by Springer Nature in Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine
- Vol. 19 (1) , 1-8
Laypersons can successfully place supraglottic airways with 3 minutes of training. A comparison of four different devices in the manikin
Supraglottic airway devices have frequently been shown to facilitate airway management and are implemented in the ILCOR resuscitation algorithm. Limited data exists concerning laypersons without any medical or paramedical background. We hypothesized that even laymen would be able to operate supraglottic airway devices after a brief training session. Four different supraglottic airway devices: Laryngeal Mask Classic (LMA), Laryngeal Tube (LT), Intubating Laryngeal Mask (FT) and CobraPLA (Cobra) were tested in 141 volunteers recruited in a technical university cafeteria and in a shopping mall. All volunteers received a brief standardized training session. Primary endpoint was the time required to definitive insertion. In a short questionnaire applicants were asked to assess the devices and to answer some general questions about BLS. The longest time to insertion was observed for Cobra (31.9 ± 27.9 s, range: 9-120, p < 0.0001; all means ± standard deviation). There was no significant difference between the insertion times of the other three devices. Fewest insertion attempts were needed for the FT (1.07 ± 0.26), followed by the LMA (1.23 ± 0.52, p > 0.05), the LT (1.36 ± 0.61, p < 0.05) and the Cobra (1.45 ± 0.7, p < 0.0001). Ventilation was achieved on the first attempt significantly more often with the FT (p < 0.001) compared to the other devices. Nearly 90% of the participants were in favor of implementing supraglottic airway devices in first aid algorithms and classes. Laypersons are able to operate supraglottic airway devices in manikin with minimal instruction. Ventilation was achieved with all devices tested after a reasonable time and with a high success rate of > 95%. The use of supraglottic airway devices in first aid and BLS algorithms should be considered.
- 1 January 2011
- Published by Springer Nature in Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine
- Vol. 19 (1) , 1-8
Open AccessLaypersons can successfully place supraglottic airways with 3 minutes of training. A comparison of four different devices in the manikin
Supraglottic airway devices have frequently been shown to facilitate airway management and are implemented in the ILCOR resuscitation algorithm. Limited data exists concerning laypersons without any medical or paramedical background. We hypothesized that even laymen would be able to operate supraglottic airway devices after a brief training session. Four different supraglottic airway devices: Laryngeal Mask Classic (LMA), Laryngeal Tube (LT), Intubating Laryngeal Mask (FT) and CobraPLA (Cobra) were tested in 141 volunteers recruited in a technical university cafeteria and in a shopping mall. All volunteers received a brief standardized training session. Primary endpoint was the time required to definitive insertion. In a short questionnaire applicants were asked to assess the devices and to answer some general questions about BLS. The longest time to insertion was observed for Cobra (31.9 ± 27.9 s, range: 9-120, p < 0.0001; all means ± standard deviation). There was no significant difference between the insertion times of the other three devices. Fewest insertion attempts were needed for the FT (1.07 ± 0.26), followed by the LMA (1.23 ± 0.52, p > 0.05), the LT (1.36 ± 0.61, p < 0.05) and the Cobra (1.45 ± 0.7, p < 0.0001). Ventilation was achieved on the first attempt significantly more often with the FT (p < 0.001) compared to the other devices. Nearly 90% of the participants were in favor of implementing supraglottic airway devices in first aid algorithms and classes. Laypersons are able to operate supraglottic airway devices in manikin with minimal instruction. Ventilation was achieved with all devices tested after a reasonable time and with a high success rate of > 95%. The use of supraglottic airway devices in first aid and BLS algorithms should be considered.