Stefan Lakemeier
Research Subjects
Stefan Lakemeier has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Markus Dietmar Schofer
Department of Orthopaedics, University Hospital Marburg, Baldingerstrasse, 35033 Marburg, Germany
9 shared publications - Susanne Fuchs-Winkelmann
Department of Orthopaedics and Rheumatology, University Hospital Marburg, Baldingerstrasse, 35043 Marburg, Germany
6 shared publications - Nina Timmesfeld
Department of Medical Informatics, Biometry and Epidemiology, Ruhr University Bochum, Bochum, Germany
4 shared publications - Thomas Jan Heyse
Center of Orthopedics and Trauma Surgery, University Hospital Marburg, Baldingerstrasse, 35043, Marburg, Germany.
4 shared publications - Christian-Dominik Peterlein
Department of Orthopaedics and Rheumatology, University Hospital Giessen and Marburg, Marburg, Germany
3 shared publications - Jürgen Rudolf Josef Paletta
Department of Orthopedics and Rheumatology, University Hospital Marburg, Marburg, Germany
3 shared publications
Latest Publications
- 4 November 2011
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 154 (2) , 359-365
Increased expression of CD44 in hypertrophied ligamentum flavum and relevance of splice variants CD44v5 and CD44v6
The most common spinal disorder in the elderly is lumbar spinal stenosis (LSS), which results in part from ligamentum flavum (LF) hypertrophy. Although prior histologic and immunochemical studies have been performed in this area, the pathophysiology of loss of elasticity and hypertrophy is not completely understood. The purpose of this immunohistological study is to elucidate the role of CD44 and its splice variants CD44v5 and CD44v6 in the hypertrophied LF obtained from patients with lumbar spinal stenosis (LSS). LF samples of 38 patients with LSS were harvested during spinal decompression. Twelve LF samples obtained from patients with disc herniation and no visible degeneration on preoperative MRI were obtained as controls. Samples were dehydrated and embedded in paraffin. For immunohistochemical determination, slices were stained with antibodies against CD44, Cd44v4, and CD44v6 stained with DAB. LF hypertrophy and cross-sectional area (CSA) were measured with T1-weighted MRI. CD44 and CD44v5 expression were significantly increased in the hypertrophy group (p < 0.05). CD44v6 expression was not significantly increased. The number of elastic fibers was significantly higher in the hypertrophy group. In the hypertrophy group, LF thickness was significantly increased while CSA was significantly decreased. There was a statistical correlation between LF thickness, CSA, CD44, and CD44v5 expression in the hypertrophy group (p < 0.05). LF hypertrophy is accompanied by increased CD44 and CD44v5 expression. CD44v6 expression is not enhanced in LF hypertrophy.
- 4 November 2011
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 154 (2) , 359-365
Increased expression of CD44 in hypertrophied ligamentum flavum and relevance of splice variants CD44v5 and CD44v6
The most common spinal disorder in the elderly is lumbar spinal stenosis (LSS), which results in part from ligamentum flavum (LF) hypertrophy. Although prior histologic and immunochemical studies have been performed in this area, the pathophysiology of loss of elasticity and hypertrophy is not completely understood. The purpose of this immunohistological study is to elucidate the role of CD44 and its splice variants CD44v5 and CD44v6 in the hypertrophied LF obtained from patients with lumbar spinal stenosis (LSS). LF samples of 38 patients with LSS were harvested during spinal decompression. Twelve LF samples obtained from patients with disc herniation and no visible degeneration on preoperative MRI were obtained as controls. Samples were dehydrated and embedded in paraffin. For immunohistochemical determination, slices were stained with antibodies against CD44, Cd44v4, and CD44v6 stained with DAB. LF hypertrophy and cross-sectional area (CSA) were measured with T1-weighted MRI. CD44 and CD44v5 expression were significantly increased in the hypertrophy group (p < 0.05). CD44v6 expression was not significantly increased. The number of elastic fibers was significantly higher in the hypertrophy group. In the hypertrophy group, LF thickness was significantly increased while CSA was significantly decreased. There was a statistical correlation between LF thickness, CSA, CD44, and CD44v5 expression in the hypertrophy group (p < 0.05). LF hypertrophy is accompanied by increased CD44 and CD44v5 expression. CD44v6 expression is not enhanced in LF hypertrophy.
- Open Access
- 21 July 2011
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 12 (1) , 168
Objective Assessment of shoulder mobility with a new 3D gyroscope - a validation study
Assessment of shoulder mobility is essential for clinical follow-up of shoulder treatment. Only a few high sophisticated instruments for objective measurements of shoulder mobility are available. The interobserver dependency of conventional goniometer measurements is high. In the 1990s an isokinetic measuring system of BIODEX Inc. was introduced, which is a very complex but valid instrument. Since 2008 a new user-friendly system called DynaPort MiniMod TriGyro ShoulderTest-System (DP) is available. Aim of this study is the validation of this measuring instrument using the BIODEX-System.
- 21 July 2011
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 12 (1) , 168
Open AccessObjective Assessment of shoulder mobility with a new 3D gyroscope - a validation study
Assessment of shoulder mobility is essential for clinical follow-up of shoulder treatment. Only a few high sophisticated instruments for objective measurements of shoulder mobility are available. The interobserver dependency of conventional goniometer measurements is high. In the 1990s an isokinetic measuring system of BIODEX Inc. was introduced, which is a very complex but valid instrument. Since 2008 a new user-friendly system called DynaPort MiniMod TriGyro ShoulderTest-System (DP) is available. Aim of this study is the validation of this measuring instrument using the BIODEX-System.
- Open Access
- 13 March 2011
- Published by Springer Nature in Journal of Medical Case Reports
- Vol. 5 (1) , 101
Primary pyogenic spondylitis following kyphoplasty: a case report
Only ten cases of primary pyogenic spondylitis following vertebroplasty have been reported in the literature. To the best of our knowledge, we present the first reported case of primary pyogenic spondylitis and spondylodiscitis caused by kyphoplasty.
- 13 March 2011
- Published by Springer Nature in Journal of Medical Case Reports
- Vol. 5 (1) , 101
Open AccessPrimary pyogenic spondylitis following kyphoplasty: a case report
Only ten cases of primary pyogenic spondylitis following vertebroplasty have been reported in the literature. To the best of our knowledge, we present the first reported case of primary pyogenic spondylitis and spondylodiscitis caused by kyphoplasty.
- Open Access
- 14 February 2011
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 12 (1) , 46
Closing-wedge high tibial osteotomy: survival and risk factor analysis at long-term follow up
Closing-wedge high tibial osteotomy (HTO) is successful for the treatment of medial osteoarthritis with varus malalignment. Preoperative risk factors for HTO failure are still controversial. The aim of this study was to elucidate the outcome and assess the influence of risk factors on long term HTO survival.
- 14 February 2011
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 12 (1) , 46
Open AccessClosing-wedge high tibial osteotomy: survival and risk factor analysis at long-term follow up
Closing-wedge high tibial osteotomy (HTO) is successful for the treatment of medial osteoarthritis with varus malalignment. Preoperative risk factors for HTO failure are still controversial. The aim of this study was to elucidate the outcome and assess the influence of risk factors on long term HTO survival.
- 11 January 2011
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 19 (10) , 1760-1765
Expression of matrix metalloproteinases 1, 3, and 9 in differing extents of tendon retraction in the torn rotator cuff
Purpose: Differing extents of tendon retraction are found in full‐thickness rotator cuff tears. The pathophysiologic context of tendon degeneration and the extent of tendon retraction are unclear. Tendon integrity depends on the extracellular matrix, which is regulated by matrix metalloproteinases (MMP). It is unknown which enzymes play a role in tendon degeneration. The hypotheses are that (1) the expression of MMPs 1, 3, and 9 is altered in the torn rotator cuff when compared with healthy tendon samples; and (2) that there is a relationship between MMP expression and the extent of tendon retraction in the torn cuff.Methods: Rotator cuff tendon samples of 33 patients with full‐thickness rotator cuff tears (Bateman grade III) were harvested during reconstructive surgery. Samples were dehydrated and paraffin‐embedded. Immunohistologic determination of MMP 1, 3, and 9 expression was performed by staining sample slices with MMP antibody. The extent of tendon retraction was determined intraoperatively according to Patte’s classification and patients were assigned to 4 groups (control group, and by tendon retraction grade Patte I‐III). The control group consisted of six healthy tendon samples.Results: Expression of MMPs 1 and 9 was significantly higher in torn cuff samples than in healthy tendons whereas MMP 3 expression was significantly decreased (P < 0.05). MMP 9 expression significantly increased with rising extent of tendon retraction in the torn cuff (P < 0.05). No significant association was found between expression of MMPs 1 and 3 and the rising extent of tendon retraction by Patte’s classification.Conclusion: Elevated expression of MMPs 1 and 9 as well as decreased MMP 3 expression can be detected in torn rotator cuff tendon tissue. There is a significant association between the extent of tendon retraction and MMP 9 expression. The results of this study give evidence that early surgical treatment of small and partial‐thickness rotator cuff tears is required.
- 11 January 2011
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 19 (10) , 1760-1765
Expression of matrix metalloproteinases 1, 3, and 9 in differing extents of tendon retraction in the torn rotator cuff
Purpose: Differing extents of tendon retraction are found in full‐thickness rotator cuff tears. The pathophysiologic context of tendon degeneration and the extent of tendon retraction are unclear. Tendon integrity depends on the extracellular matrix, which is regulated by matrix metalloproteinases (MMP). It is unknown which enzymes play a role in tendon degeneration. The hypotheses are that (1) the expression of MMPs 1, 3, and 9 is altered in the torn rotator cuff when compared with healthy tendon samples; and (2) that there is a relationship between MMP expression and the extent of tendon retraction in the torn cuff.Methods: Rotator cuff tendon samples of 33 patients with full‐thickness rotator cuff tears (Bateman grade III) were harvested during reconstructive surgery. Samples were dehydrated and paraffin‐embedded. Immunohistologic determination of MMP 1, 3, and 9 expression was performed by staining sample slices with MMP antibody. The extent of tendon retraction was determined intraoperatively according to Patte’s classification and patients were assigned to 4 groups (control group, and by tendon retraction grade Patte I‐III). The control group consisted of six healthy tendon samples.Results: Expression of MMPs 1 and 9 was significantly higher in torn cuff samples than in healthy tendons whereas MMP 3 expression was significantly decreased (P < 0.05). MMP 9 expression significantly increased with rising extent of tendon retraction in the torn cuff (P < 0.05). No significant association was found between expression of MMPs 1 and 3 and the rising extent of tendon retraction by Patte’s classification.Conclusion: Elevated expression of MMPs 1 and 9 as well as decreased MMP 3 expression can be detected in torn rotator cuff tendon tissue. There is a significant association between the extent of tendon retraction and MMP 9 expression. The results of this study give evidence that early surgical treatment of small and partial‐thickness rotator cuff tears is required.
- Open Access
- 24 December 2010
- Published by Springer Nature in BMC Pediatrics
- Vol. 10 (1) , 98
Reproducibility of different screening classifications in ultrasonography of the newborn hip
Ultrasonography of the hip has gained wide acceptance as a primary method for diagnosis, screening and treatment monitoring of developmental hip dysplasia in infants. The aim of the study was to examine the degree of concordance of two objective classifications of hip morphology and subjective parameters by three investigators with different levels of experience.
- 24 December 2010
- Published by Springer Nature in BMC Pediatrics
- Vol. 10 (1) , 98
Open AccessReproducibility of different screening classifications in ultrasonography of the newborn hip
Ultrasonography of the hip has gained wide acceptance as a primary method for diagnosis, screening and treatment monitoring of developmental hip dysplasia in infants. The aim of the study was to examine the degree of concordance of two objective classifications of hip morphology and subjective parameters by three investigators with different levels of experience.
- Open Access
- 25 November 2010
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 11 (1) , 271
Expression of matrix metalloproteinases 1, 3, and 9 in degenerated long head biceps tendon in the presence of rotator cuff tears: an immunohistological study
Long head biceps (LHB) degeneration, in combination with rotator cuff tears, can be a source of chronic shoulder pain. LHB tenotomy reduces pain and improves joint function although the pathophysiological context is not well understood. Tendon integrity depends on the extracellular matrix (ECM), which is regulated by matrix metalloproteinases (MMP). It is unclear which of these enzymes contribute to LHB but we chose to study MMP 1, 3, and 9 and hypothesized that one or more of them may be altered in LHB, whether diagnosed preoperatively or intraoperatively. We compared expression of these MMPs in both LHB and healthy tendon samples.
- 25 November 2010
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 11 (1) , 271
Open AccessExpression of matrix metalloproteinases 1, 3, and 9 in degenerated long head biceps tendon in the presence of rotator cuff tears: an immunohistological study
Long head biceps (LHB) degeneration, in combination with rotator cuff tears, can be a source of chronic shoulder pain. LHB tenotomy reduces pain and improves joint function although the pathophysiological context is not well understood. Tendon integrity depends on the extracellular matrix (ECM), which is regulated by matrix metalloproteinases (MMP). It is unclear which of these enzymes contribute to LHB but we chose to study MMP 1, 3, and 9 and hypothesized that one or more of them may be altered in LHB, whether diagnosed preoperatively or intraoperatively. We compared expression of these MMPs in both LHB and healthy tendon samples.
- Open Access
- 8 October 2010
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 11 (1) , 230
The association between retraction of the torn rotator cuff and increasing expression of hypoxia inducible factor 1α and vascular endothelial growth factor expression: an immunohistological study
Differing levels of tendon retraction are found in full-thickness rotator cuff tears. The pathophysiology of tendon degeneration and retraction is unclear. Neoangiogenesis in tendon parenchyma indicates degeneration. Hypoxia inducible factor 1α (HIF) and vascular endothelial growth factor (VEGF) are important inducers of neoangiogenesis. Rotator cuff tendons rupture leads to fatty muscle infiltration (FI) and muscle atrophy (MA). The aim of this study is to clarify the relationship between HIF and VEGF expression, neoangiogenesis, FI, and MA in tendon retraction found in full-thickness rotator cuff tears.
- 8 October 2010
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 11 (1) , 230
Open AccessThe association between retraction of the torn rotator cuff and increasing expression of hypoxia inducible factor 1α and vascular endothelial growth factor expression: an immunohistological study
Differing levels of tendon retraction are found in full-thickness rotator cuff tears. The pathophysiology of tendon degeneration and retraction is unclear. Neoangiogenesis in tendon parenchyma indicates degeneration. Hypoxia inducible factor 1α (HIF) and vascular endothelial growth factor (VEGF) are important inducers of neoangiogenesis. Rotator cuff tendons rupture leads to fatty muscle infiltration (FI) and muscle atrophy (MA). The aim of this study is to clarify the relationship between HIF and VEGF expression, neoangiogenesis, FI, and MA in tendon retraction found in full-thickness rotator cuff tears.
- Open Access
- 27 August 2010
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 11 (1) , 191
The relevance of long head biceps degeneration in the presence of rotator cuff tears
Long head biceps (LHB) degeneration in combination with rotator cuff tears can be a source of chronic shoulder pain. LHB tenotomy is an approved surgical procedure for pain reduction and improvement of joint function, however, the pathophysiology of LHB degeneration is not fully understood. In the literature, neoangiogenesis in tendon tissue has previously been shown to be associated with tendon degeneration. Vascular Endothelial Growth Factor (VEGF) is an important inducer of neoangiogenesis. The hypotheses are first that an elevated VEGF expression and vessel density can be found in degenerated LHB tissue and second that there is a relation between VEGF expression, vessel density and the different types of rotator cuff tears.LHB samples of 116 patients with degenerative rotator cuff tears were harvested during arthroscopic tenotomy. The samples were dehydrated and paraffin embedded. VEGF expression was determined using immunohistochemistry. Vessel density and vessel size were determined on Masson-Goldner stained tissue sections. On the basis of intraoperative findings, patients were assigned to 4 different groups (control group, partial thickness rotator cuff tear, full thickness rotator cuff tear and cuff arthropathy). Partial thickness rotator cuff tears were classified according to Ellman grade I-III, full thickness rotator cuff tears according to Bateman's classification (grade I-IV). The control group consisted of eight healthy tendon samples.VEGF expression in the LHB was significantly higher in the presence of rotator cuff tears than in healthy tendons (p < 0.05) whereas vessel density and vessel size were significantly higher in the LHB of patients with cuff arthropathy (p < 0.05). Furthermore, there was significantly higher VEGF expression in LHB samples from patients with articular-sided compared to bursal-sided partial thickness rotator cuff tears (p < 0.05). No significant dependence was found between VEGF expression, vessel size and vessel density in LHB of patients with full thickness rotator cuff tears and the extent of the cuff tear following Bateman's classification.Elevated VEGF expression can be detected in degenerated LHB tissue. The quantity of VEGF expression and vessels are related to the extent of LHB degeneration.
- 27 August 2010
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 11 (1) , 191
Open AccessThe relevance of long head biceps degeneration in the presence of rotator cuff tears
Long head biceps (LHB) degeneration in combination with rotator cuff tears can be a source of chronic shoulder pain. LHB tenotomy is an approved surgical procedure for pain reduction and improvement of joint function, however, the pathophysiology of LHB degeneration is not fully understood. In the literature, neoangiogenesis in tendon tissue has previously been shown to be associated with tendon degeneration. Vascular Endothelial Growth Factor (VEGF) is an important inducer of neoangiogenesis. The hypotheses are first that an elevated VEGF expression and vessel density can be found in degenerated LHB tissue and second that there is a relation between VEGF expression, vessel density and the different types of rotator cuff tears.LHB samples of 116 patients with degenerative rotator cuff tears were harvested during arthroscopic tenotomy. The samples were dehydrated and paraffin embedded. VEGF expression was determined using immunohistochemistry. Vessel density and vessel size were determined on Masson-Goldner stained tissue sections. On the basis of intraoperative findings, patients were assigned to 4 different groups (control group, partial thickness rotator cuff tear, full thickness rotator cuff tear and cuff arthropathy). Partial thickness rotator cuff tears were classified according to Ellman grade I-III, full thickness rotator cuff tears according to Bateman's classification (grade I-IV). The control group consisted of eight healthy tendon samples.VEGF expression in the LHB was significantly higher in the presence of rotator cuff tears than in healthy tendons (p < 0.05) whereas vessel density and vessel size were significantly higher in the LHB of patients with cuff arthropathy (p < 0.05). Furthermore, there was significantly higher VEGF expression in LHB samples from patients with articular-sided compared to bursal-sided partial thickness rotator cuff tears (p < 0.05). No significant dependence was found between VEGF expression, vessel size and vessel density in LHB of patients with full thickness rotator cuff tears and the extent of the cuff tear following Bateman's classification.Elevated VEGF expression can be detected in degenerated LHB tissue. The quantity of VEGF expression and vessels are related to the extent of LHB degeneration.
- Open Access
- 27 May 2010
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 11 (1) , 101
Results of the cementless Plasmacup in revision total hip arthroplasty: a retrospective study of 72 cases with an average follow-up of eight years
There are multiple revision implant systems currently available for socket revision in revision total hip arthroplasty. Up until now, not all of these systems have been followed up with regards to their long-term use as a revision implantation.
- 27 May 2010
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 11 (1) , 101
Open AccessResults of the cementless Plasmacup in revision total hip arthroplasty: a retrospective study of 72 cases with an average follow-up of eight years
There are multiple revision implant systems currently available for socket revision in revision total hip arthroplasty. Up until now, not all of these systems have been followed up with regards to their long-term use as a revision implantation.