JHJan Höcker

Jan Höcker

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jan Höcker has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Correlation, accuracy, precision and practicability of perioperative measurement of sublingual temperature in comparison with tympanic membrane temperature in awake and anaesthetised patients

    by Jan Höcker, Berthold Bein, Ruwen Böhm, Markus Steinfath, Jens Scholz, Ernst-Peter Horn

    The prevention of inadvertent perioperative hypothermia requires precise, reliable and practical methods of temperature measurement in both awake and anaesthetised patients. Different methods and sites of monitoring have been evaluated, but many are imprecise, unusable in awake patients, difficult to apply or too invasive, especially for minor surgery. The aim of this study was to evaluate the performance of perioperative sublingual and tympanic temperature measurement in awake and anaesthetised patients. We enrolled 171 patients, aged 18-75 years, scheduled for surgery with duration less than 1 h under general anaesthesia. Spearman's rank correlation and Bland-Altman analysis for assessment of correlation, accuracy and precision of both methods were determined analysing 171 independent paired values at three different measurement times. Sublingual temperatures were significantly higher than tympanic temperatures by 0.1-0.2°C. The coefficient of determination (r) of both methods was between 0.50 and 0.59, and Bland-Altman analysis revealed a bias (SD) of between -0.09 (0.21) and -0.15 (0.24)°C. The accuracy and precision of sublingual temperature measurement were adequate for clinical use, and there was a high correlation with tympanic temperature monitoring. Sublingual temperature measurement has been demonstrated as a good and practical modality for perioperative temperature monitoring in both awake and anaesthetised patients.


  • Open Access

    Uncalibrated pulse power analysis fails to reliably measure cardiac output in patients undergoing coronary artery bypass surgery

    by Ole Broch, Jochen Renner, Jan Höcker, Matthias Gruenewald, Patrick Meybohm, Jan Schöttler, Markus Steinfath, Berthold Bein

    Introduction: Uncalibrated arterial pulse power analysis has been recently introduced for continuous monitoring of cardiac index (CI). The aim of the present study was to compare the accuracy of arterial pulse power analysis with intermittent transpulmonary thermodilution (TPTD) before and after cardiopulmonary bypass (CPB). Methods: Forty-two patients scheduled for elective coronary surgery were studied after induction of anaesthesia, before and after CPB respectively. Each patient was monitored with the pulse contour cardiac output (PiCCO) system, a central venous line and the recently introduced LiDCO monitoring system. Haemodynamic variables included measurement of CI derived by transpulmonary thermodilution (CITPTD) or CI derived by pulse power analysis (CIPP), before and after calibration (CIPPnon-cal., CIPPcal.). Percentage changes of CI (ΔCITPTD, ΔCIPPnon-cal./PPcal.) were calculated to analyse directional changes. Results: Before CPB there was no significant correlation between CIPPnon-cal. and CITPTD (r2 = 0.04, P = 0.08) with a percentage error (PE) of 86%. Higher mean arterial pressure (MAP) values were significantly correlated with higher CIPPnon-cal. (r2 = 0.26, P < 0.0001). After CPB, CIPPcal. revealed a significant correlation compared with CITPTD (r2 = 0.77, P < 0.0001) with PE of 28%. Changes in CIPPcal. (ΔCIPPcal.) showed a correlation with changes in CITPTD (ΔCITPTD) only after CPB (r2 = 0.52, P = 0.005). Conclusions: Uncalibrated pulse power analysis was significantly influenced by MAP and was not able to reliably measure CI compared with TPTD. Calibration improved accuracy, but pulse power analysis was still not consistently interchangeable with TPTD. Only calibrated pulse power analysis was able to reliably track haemodynamic changes and trends.


  • Surgical stress index in response to pacemaker stimulation or atropine

    by J Höcker, O Broch, J.TH. Gräsner, M Gruenewald, C Ilies, M Steinfath, B Bein

    The surgical stress index (SSI) is a new monitoring tool for the assessment of nociception during general anaesthesia. It is calculated based on the heart beat interval and the pulse wave amplitude. Correlation of SSI with nociceptive stimuli and opioid effect-site concentrations has been demonstrated, but the influence of isolated modulation of heart rate (HR) on SSI is still unclear. The aim of this study was to evaluate the effect on SSI of atropine administration and cardiac pacing. In 18 anaesthetized ASA III ICU patients, either repetitive cardiac pacemaker stimulation or administration of atropine (10 microg kg(-1)) was performed, and the effect on SSI, arterial pressure, spectral entropy, and bispectral index was analysed. Cardiac pacing at 100 beats min(-1) was followed by an increase in SSI from 26 [17-35 (10-41)] to 59 [53-72 (48-78)] {median [inter-quartile range (range)]} (P=0.0006), whereas other variables remained unaffected. Also, atropine administration increased SSI from 27 [20-34 (16-39)] to 58 [48-70 (41-81)] (P=0.007) without significant effect on other variables except HR. A recalibration of SSI during cardiac pacing leads to a significant decrease in SSI to 49 [40-52 (36-57)] (P=0.03), whereas recalibration after atropine administration had no effect. SSI values measured in patients receiving atropine or in patients with pacemakers should be interpreted cautiously.


  • Retracted

    Differences between bispectral index and spectral entropy during xenon anaesthesia: a comparison with propofol anaesthesia

    by J. Höcker, B. Raitschew, P. Meybohm, O. Broch, C. Stapelfeldt, M. Gruenewald, E. Cavus, M. Steinfath, B. Bein

    Summary: We enrolled 114 patients, aged 65–83 years, undergoing elective surgery (duration > 2h) into a randomised, controlled study to evaluate the performance of bispectral index and spectral entropy for monitoring depth of xenon versus propofol anaesthesia. In the propofol group, bispectral index and state entropy values were comparable. In the xenon group, bispectral index values resembled those in the propofol group, but spectral entropy levels were significantly lower. Mean arterial blood pressure was higher and heart rate was lower in the xenon group than in the propofol group. Bispectral index and spectral entropy considerably diverged during xenon but not during propofol anaesthesia. We therefore conclude that these measures are not interchangeable for the assessment of depth of hypnosis and that bispectral index is likely to reflect actual depth of anaesthesia more precisely compared with spectral entropy.


  • Nefopam but not physostigmine affects the thermoregulatory response in mice via α2-adrenoceptors

    by Jan Höcker, Matthias Gruenewald, Patrick Meybohm, Christian Schaper, Jens Scholz, Markus Steinfath, Berthold Bein


  • Retracted

    Postoperative Neurocognitive Dysfunction in Elderly Patients after Xenon versus Propofol Anesthesia for Major Noncardiac Surgery

    by Jan Höcker, Claudia Stapelfeldt, Jörn Leiendecker, Patrick Meybohm, Robert Hanss, Jens Scholz, Berthold Bein

    Background: Postoperative cognitive dysfunction (POCD) in elderly patients after noncardiac surgery is a common problem. The noble gas xenon has been demonstrated to exert substantial neuroprotective properties in animal studies. Therefore, this study was designed to assess POCD after xenon anesthesia in comparison to propofol in elderly patients undergoing major noncardiac surgery. Methods: After approval of the local ethical committee was obtained, 101 patients (American Society of Anesthesiologists physical status I-III; age, 65-83 yr) undergoing elective abdominal or urologic surgery (duration, > 2 h) were enrolled into this randomized, double-blinded controlled pilot study. Patients received anesthesia with sufentanil and either propofol or xenon and were assessed before treatment and 1, 6, and 30 days after treatment using a neuropsychological test battery based on previous studies investigating POCD. Results: There were no significant differences in terms of age, American Society of Anesthesiologists status, education, duration of surgery, administered analgetics, and preoperative neurocognitive status between study groups. POCD as classified was present in 22 patients (44%) of the xenon group versus 25 patients (50%) of the propofol group 1 day after treatment, in 6 xenon patients (12%) versus 9 propofol patients (18%) 6 days after treatment, and in 3 xenon patients (6%) versus 6 propofol patients (12%) 30 days after treatment. These differences were not statistically significant. Conclusion: Postoperative impairment of neurocognitive function was observed in a substantial proportion of elderly patients even 30 days after treatment. Xenon-based anesthesia was not associated with decreased incidence of POCD in comparison to propofol.


  • Open Access

    Reliability of continuous cardiac output measurement during intra-abdominal hypertension relies on repeated calibrations: an experimental animal study

    by Matthias Gruenewald, Jochen Renner, Patrick Meybohm, Jan Höcker, Jens Scholz, Berthold Bein

    Introduction: Monitoring cardiac output (CO) may allow early detection of haemodynamic instability, aiming to reduce morbidity and mortality in critically ill patients. Continuous cardiac output (CCO) monitoring is recommended in septic or postoperative patients with high incidences of intra-abdominal hypertension (IAH). The aim of the present study was to compare the agreement between three CCO methods and a bolus thermodilution CO technique during acute IAH and volume loading. Methods: Ten pigs were anaesthetised and instrumented for haemodynamic measurements. Cardiac output was obtained using CCO by pulse power analysis (PulseCO; LiDCO monitor), using CCO by pulse contour analysis (PCCO; PiCCO monitor) and using CCO by pulmonary artery catheter thermodilution (CCOPAC), and was compared with bolus transcardiopulmonary thermodilution CO (COTCP) at baseline, after fluid loading, at IAH and after an additional fluid loading at IAH. Whereas PulseCO was only calibrated at baseline, PCCO was calibrated at each experimental step. Results: PulseCO and PCCO underestimated CO, as the overall bias ± standard deviation was 1.0 ± 1.5 l/min and 1.0 ± 1.1 l/min compared with COTCP. A clinically accepted agreement between all of the CCO methods and COTCP was observed only at baseline. Whereas IAH did not influence the CO, increased CO following fluid loading at IAH was only reflected by CCOPAC and COTCP, not by uncalibrated PulseCO and PCCO. After recalibration, PCCO was comparable with COTCP. Conclusions: The CO obtained by uncalibrated PulseCO and PCCO failed to agree with COTCP during IAH and fluid loading. In the critically ill patient, recalibration of continuous arterial waveform CO methods should be performed after fluid loading or before a major change in therapy is initiated.


  • Differential Effects of α2-adrenoceptors in the Modulation of the Thermoregulatory Response in Mice Induced by Meperidine

    by Jan Höcker, Andrea Paris, Jens Scholz, Peter H. Tonner, Martin Nielsen, Berthold Bein

    POSTANESTHETIC shivering is characterized by involuntary muscle activity, especially during the early postoperative period, and can be treated pharmacologically with opioids or α2-adrenoceptor agonists. Though the underlying mechanisms of shivering are not completely understood, a major contributing factor is perioperative hypothermia mediated by anesthetic-induced inhibition of thermoregulation.1,2