Antonio Lleó-Pérez
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Antonio Lleó-Pérez has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Juan Alberto Sanchis Gimeno
GIAVAL Research Group, Department of Human Anatomy and Embryology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain
4 shared publications L Alonso Muñoz
Clínica Oftalmológica Rahhal, Valencia, España
2 shared publicationsM.S. Rahhal
Rahhal Ophthalmology Clinic, Valencia, Spain
2 shared publicationsA. Ortuño-Soto
Rahhal Ophthalmology Clinic, Faculty of Medicine, University of Valencia - Spain
1 shared publication- Alex Gallego-Martínez
Ophthalmic Research Unit “Santiago Grisolía”/FISABIO, 46017 Valencia, Spain
1 shared publication Amparo Ortuño-Soto
Rahhal Ophthalmology Clinic, Valencia, Spain
1 shared publication
Latest Publications
- Open Access
- 22 December 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (1) , 74
Oxidative Stress Mediates Epigenetic Modifications and the Expression of miRNAs and Genes Related to Apoptosis in Diabetic Retinopathy Patients
Knowledge on the underlying mechanisms and molecular targets for managing the ocular complications of type 2 diabetes mellitus (T2DM) remains incomplete. Diabetic retinopathy (DR) is a major cause of irreversible visual disability worldwide. By using ophthalmological and molecular-genetic approaches, we gathered specific information to build a data network for deciphering the crosslink of oxidative stress (OS) and apoptosis (AP) processes, as well as to identify potential epigenetic modifications related to noncoding RNAs in the eyes of patients with T2DM. A total of 120 participants were recruited, being classified into two groups: individuals with T2MD (T2MDG, n = 67), divided into a group of individuals with (+DR, n = 49) and without (−DR, n = 18) DR, and a control group (CG, n = 53). Analyses of compiled data reflected significantly higher plasma levels of malondialdehyde (MDA), superoxide dismutase (SOD), and glutathione peroxidase (GPx) and significantly lower total antioxidant capacity (TAC) in the +DR patients compared with the −DR and the CG groups. Furthermore, the plasma caspase-3 (CAS3), highly involved in apoptosis (AP), showed significantly higher values in the +DR group than in the −DR patients. The microRNAs (miR) hsa-miR 10a-5p and hsa-miR 15b-5p, as well as the genes BCL2L2 and TP53 involved in these pathways, were identified in relation to DR clinical changes. Our data suggest an interaction between OS and the above players in DR pathogenesis. Furthermore, potential miRNA-regulated target genes were identified in relation to DR. In this concern, we may raise new diagnostic and therapeutic challenges that hold the potential to significantly improve managing the diabetic eye.
- 22 December 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (1) , 74
Open AccessOxidative Stress Mediates Epigenetic Modifications and the Expression of miRNAs and Genes Related to Apoptosis in Diabetic Retinopathy Patients
Knowledge on the underlying mechanisms and molecular targets for managing the ocular complications of type 2 diabetes mellitus (T2DM) remains incomplete. Diabetic retinopathy (DR) is a major cause of irreversible visual disability worldwide. By using ophthalmological and molecular-genetic approaches, we gathered specific information to build a data network for deciphering the crosslink of oxidative stress (OS) and apoptosis (AP) processes, as well as to identify potential epigenetic modifications related to noncoding RNAs in the eyes of patients with T2DM. A total of 120 participants were recruited, being classified into two groups: individuals with T2MD (T2MDG, n = 67), divided into a group of individuals with (+DR, n = 49) and without (−DR, n = 18) DR, and a control group (CG, n = 53). Analyses of compiled data reflected significantly higher plasma levels of malondialdehyde (MDA), superoxide dismutase (SOD), and glutathione peroxidase (GPx) and significantly lower total antioxidant capacity (TAC) in the +DR patients compared with the −DR and the CG groups. Furthermore, the plasma caspase-3 (CAS3), highly involved in apoptosis (AP), showed significantly higher values in the +DR group than in the −DR patients. The microRNAs (miR) hsa-miR 10a-5p and hsa-miR 15b-5p, as well as the genes BCL2L2 and TP53 involved in these pathways, were identified in relation to DR clinical changes. Our data suggest an interaction between OS and the above players in DR pathogenesis. Furthermore, potential miRNA-regulated target genes were identified in relation to DR. In this concern, we may raise new diagnostic and therapeutic challenges that hold the potential to significantly improve managing the diabetic eye.
- Open Access
- 1 January 2009
- Published by Elsevier in Journal of Optometry
- Vol. 2 (1) , 39-50
Relationship Between Visual Field Sensitivity and Retinal Nerve Fiber Layer Thickness Measured by Scanning Laser Polarimetry and Optical Coherence Tomography in Normal, Ocular Hypertensive and Glaucomatous Eyes
- 1 January 2009
- Published by Elsevier in Journal of Optometry
- Vol. 2 (1) , 39-50
Open AccessRelationship Between Visual Field Sensitivity and Retinal Nerve Fiber Layer Thickness Measured by Scanning Laser Polarimetry and Optical Coherence Tomography in Normal, Ocular Hypertensive and Glaucomatous Eyes
- 26 February 2007
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 27 (2) , 201-209
Changes in the visual field following laser in situ keratomileusis for myopia
Purpose: To assess the changes of the visual field (VF) caused by transient intraocular pressure (IOP) peaks during laser in situ keratomileusis (LASIK) surgery for myopia using automated perimetry. Methods: This prospective study involved 94 eyes of 94 patients who underwent a conventional LASIK procedure. A complete eye examination was carried out in which the IOP measurement, and Humphrey 24‐2 SITA standard VF were tested prior to LASIK and 6 and 12 months after LASIK. Patients were divided into two subgroups according to their refractive error. VF global indices, Glaucoma Hemifield Test and the number of depressed points deviating at p < 5%, p < 2%, p < 1% and p < 0.5% on the Pattern Deviation probability maps were compared using the analysis of variance. Results: In the low myopia group, there were no significant differences in the analysed variables, except a slight decrease in mean deviation (MD) when comparing results prior to and 6 months following LASIK ( p = 0.036; anova ) that returned to baseline values at 12 months after surgery. In the moderate and high myopia group, there were no statistically significant differences in any of the variables analysed. No significant correlation was found between the transitory reduction in MD and any of the variables studied. Conclusions: In patients with low myopia, the VF undergoes a transitory increase in diffuse defects 6 months after surgery, with spontaneous recovery at 12 months after LASIK procedure. Possible explanations for these findings are discussed.
- 26 February 2007
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 27 (2) , 201-209
Changes in the visual field following laser in situ keratomileusis for myopia
Purpose: To assess the changes of the visual field (VF) caused by transient intraocular pressure (IOP) peaks during laser in situ keratomileusis (LASIK) surgery for myopia using automated perimetry. Methods: This prospective study involved 94 eyes of 94 patients who underwent a conventional LASIK procedure. A complete eye examination was carried out in which the IOP measurement, and Humphrey 24‐2 SITA standard VF were tested prior to LASIK and 6 and 12 months after LASIK. Patients were divided into two subgroups according to their refractive error. VF global indices, Glaucoma Hemifield Test and the number of depressed points deviating at p < 5%, p < 2%, p < 1% and p < 0.5% on the Pattern Deviation probability maps were compared using the analysis of variance. Results: In the low myopia group, there were no significant differences in the analysed variables, except a slight decrease in mean deviation (MD) when comparing results prior to and 6 months following LASIK ( p = 0.036; anova ) that returned to baseline values at 12 months after surgery. In the moderate and high myopia group, there were no statistically significant differences in any of the variables analysed. No significant correlation was found between the transitory reduction in MD and any of the variables studied. Conclusions: In patients with low myopia, the VF undergoes a transitory increase in diffuse defects 6 months after surgery, with spontaneous recovery at 12 months after LASIK procedure. Possible explanations for these findings are discussed.
- 1 November 2004
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 14 (6) , 523-530
Intraobserver Reproducibility of Retinal Nerve Fiber Layer Measurements Using Scanning Laser Polarimetry and Optical Coherence Tomography in Normal and Ocular Hypertensive Subjects
Purpose: To evaluate quantitatively the intraobserver reproducibility of measurements of the retinal nerve fiber layer (RNFL) in healthy subjects and an ocular hypertensive population using two nerve fiber analyzers. Methods: Sixty eyes of normal (n=30) and ocular hypertensive subjects (n=30) were consecutively recruited for this study and underwent a complete ophthalmologic examination and achromatic automated perimetry. RNFL were measured using scanning laser polarimeter (GDx-VCC) and optical coherence tomography (OCT Model 3000). Reproducibility of the RNFL measurements obtained with both nerve fiber analyzers were compared using the coefficient of variation. Results: In both groups the authors found fair correlations between the two methods in all ratio and thickness parameters. The mean coefficient of variation for measurement of the variables ranged from 2.24% to 13.12% for GDx-VCC, and from 5.01% to 9.24% for OCT Model 3000. The authors could not detect any significant differences between healthy and ocular hypertensive eyes, although in normal eyes the correlations improved slightly. Nevertheless, the test–retest correlation was slightly better for GDx-VCC than for OCT Model 3000 (5.55% and 7.11%, respectively). Conclusions: Retinal mapping software of both nerve fiber analyzers allows reproducible measurement of RNFL in both healthy subjects and ocular hypertensive eyes, and shows fair correlations and good intraobserver reproducibility. However, in our study, GDx showed a better test–retest correlation.
- 1 November 2004
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 14 (6) , 523-530
Intraobserver Reproducibility of Retinal Nerve Fiber Layer Measurements Using Scanning Laser Polarimetry and Optical Coherence Tomography in Normal and Ocular Hypertensive Subjects
Purpose: To evaluate quantitatively the intraobserver reproducibility of measurements of the retinal nerve fiber layer (RNFL) in healthy subjects and an ocular hypertensive population using two nerve fiber analyzers. Methods: Sixty eyes of normal (n=30) and ocular hypertensive subjects (n=30) were consecutively recruited for this study and underwent a complete ophthalmologic examination and achromatic automated perimetry. RNFL were measured using scanning laser polarimeter (GDx-VCC) and optical coherence tomography (OCT Model 3000). Reproducibility of the RNFL measurements obtained with both nerve fiber analyzers were compared using the coefficient of variation. Results: In both groups the authors found fair correlations between the two methods in all ratio and thickness parameters. The mean coefficient of variation for measurement of the variables ranged from 2.24% to 13.12% for GDx-VCC, and from 5.01% to 9.24% for OCT Model 3000. The authors could not detect any significant differences between healthy and ocular hypertensive eyes, although in normal eyes the correlations improved slightly. Nevertheless, the test–retest correlation was slightly better for GDx-VCC than for OCT Model 3000 (5.55% and 7.11%, respectively). Conclusions: Retinal mapping software of both nerve fiber analyzers allows reproducible measurement of RNFL in both healthy subjects and ocular hypertensive eyes, and shows fair correlations and good intraobserver reproducibility. However, in our study, GDx showed a better test–retest correlation.
- 1 December 2003
- Vol. 78 (12) , 665-73
[Comparative clinical study of visual results between two different types of bifocal intraocular lenses].
To compare visual results after cataract surgery in patients who underwent bilateral implantation of two different types of bifocal intraocular lenses: the model 811E (Pharmacia), and the model MF4 (Ioltech). This prospective study comprised 99 patients who underwent phacoemulsification with bifocal IOL implantation. The model 811E was implanted in forty-seven eyes of 47 patients (group I) and the model MF4 in fifty-two eyes of 52 patients (group II). Visual acuity (distance and near), complications, and adverse events were measured. The postoperative follow-up in all patients was of 6 months. Patient satisfaction was also valued using a questionnaire. There was no significant difference in uncorrected distance visual acuity between both groups, which was respectively 0.63 (S.D.: 0.2) for group I and 0.58 (S.D.: 0.16) for group II (p=0.17). Nonetheless a significant difference was found when measuring corrected distance visual acuity, which was 0.86 (S.D.: 0.1) for group I and 0.77 (S.D.: 0.12) for group II (p=0.01). Mean uncorrected near visual acuity was statistically better in group I: J2.00 (S.D.:1.16) in comparison with J2.48 (S.D.:0.83) for group II (p=0.021). Subjectively, both groups indicated high levels of satisfaction, without significant difference between them, being respectively 78% (group I) and 73.4% (group II). Our results reveal a superiority of the bifocal diffractive lens over the refractive bifocal lens for corrected distance visual acuity and distance-corrected near visual acuity. Postoperatory complications and satisfaction degree were similar for both IOL models.
- 1 December 2003
- Vol. 78 (12) , 665-73
[Comparative clinical study of visual results between two different types of bifocal intraocular lenses].
To compare visual results after cataract surgery in patients who underwent bilateral implantation of two different types of bifocal intraocular lenses: the model 811E (Pharmacia), and the model MF4 (Ioltech). This prospective study comprised 99 patients who underwent phacoemulsification with bifocal IOL implantation. The model 811E was implanted in forty-seven eyes of 47 patients (group I) and the model MF4 in fifty-two eyes of 52 patients (group II). Visual acuity (distance and near), complications, and adverse events were measured. The postoperative follow-up in all patients was of 6 months. Patient satisfaction was also valued using a questionnaire. There was no significant difference in uncorrected distance visual acuity between both groups, which was respectively 0.63 (S.D.: 0.2) for group I and 0.58 (S.D.: 0.16) for group II (p=0.17). Nonetheless a significant difference was found when measuring corrected distance visual acuity, which was 0.86 (S.D.: 0.1) for group I and 0.77 (S.D.: 0.12) for group II (p=0.01). Mean uncorrected near visual acuity was statistically better in group I: J2.00 (S.D.:1.16) in comparison with J2.48 (S.D.:0.83) for group II (p=0.021). Subjectively, both groups indicated high levels of satisfaction, without significant difference between them, being respectively 78% (group I) and 73.4% (group II). Our results reveal a superiority of the bifocal diffractive lens over the refractive bifocal lens for corrected distance visual acuity and distance-corrected near visual acuity. Postoperatory complications and satisfaction degree were similar for both IOL models.
- Open Access
- 1 December 2003
- Published by Elsevier in Archivos de la Sociedad Española de Oftalmología
- Vol. 78 (12) , 665-673
Estudio clínico comparativo de los resultados visuales en dos lentes intraoculares bifocales
- 1 December 2003
- Published by Elsevier in Archivos de la Sociedad Española de Oftalmología
- Vol. 78 (12) , 665-673
Open AccessEstudio clínico comparativo de los resultados visuales en dos lentes intraoculares bifocales