CMChia-Hsiang Menq

Chia-Hsiang Menq

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chia-Hsiang Menq has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Near-Wall Ultra-precise Motion Control of a Magnetically Driven Scanning Microprobe in Aqueous Solutions

    by Ta-Min Meng, Fei Long, Chia-Hsiang Menq

    As an untethered scanning probe approaches a wall in aqueous solutions, the drag coefficient increases and approaches infinity, which challenges the precise motion control of the scanning probe near the wall. This article presents a real-time estimation of space-dependent drag coefficient and unknown disturbances for a magnetically driven scanning microprobe close to a wall in aqueous solutions. The estimated drag coefficient is used to update the motion gain with a time-varying discrete-time control law to achieve a prespecified control objective for ultraprecise motion control of the scanning probe near the wall. The control law and the estimator have been integrated into a previously developed visual servo control system to achieve ultraprecise motion control of the scanning probe close to wall surfaces. The motion control system has been realized using a high-speed field programmable gate array (FPGA) system. Experiments have confirmed that near-wall ultraprecise motion control of the scanning probe has been achieved. In experiments, the tracking error of the microprobe was close to a random error with zero mean due only to random thermal forces and measurement noise. In addition, the accuracy of real-time estimation of motion gain/drag coefficient was experimentally verified.

  • Control of the Probe-Sample Interaction Force at the Piconewton Scale by a Magnetic Microprobe in Aqueous Solutions

    by Ta-Min Meng, Chia-Hsiang Menq

    This article describes the design and implementation of a control system that controls the probe-sample interaction force at the piconewton scale by manipulating a magnetic microprobe in aqueous solutions under a microscope. The control system has two functions, namely accurate force generation by magnetic flux control and precise control of the probe-sample interaction force. Magnetic flux control uses an improved six-input-six-output digital control law along with a disturbance estimator to achieve two control objectives. First, the magnetic flux at each pole tip of a previously developed hexapole electromagnetic actuator can be individually and precisely controlled at frequencies over 4 kHz, and the experimental results precisely followed the theoretical predictions based on the design. Second, together with the optimized flux allocation, the flux control system generates precise magnetic forces, making the six-input hexapole actuator behave like a decoupled three-axis force generator with a bandwidth of more than 4 kHz. Interaction force control compares the measured deformation of the sample with the expected deformation, updated in real time by a deformation predictor, to generate the magnetic force to control the interaction between the probe and the sample. Digital control laws, the estimator, and the predictor are all implemented using a high-speed Field Programmable Gate Array (FPGA) system. Experiments confirm that through mathematical modeling, digital control technology, high-speed electronics, and real-time computation, accurate three-dimensional force generation at the piconewton scale with high bandwidth and precise interaction force control with zero-mean random error, attributed to random thermal force and measurement noise, are achieved.


  • Ultra-Precise High-Speed Untethered Manipulation of Magnetic Scanning Microprobe in Aqueous Solutions

    by Ta-Min Meng, Chia-Hsiang Menq

    This article describes the design and development of an integrated system that renders ultra-precise and high-speed, untethered manipulation of a single magnetic scanning microprobe in aqueous solutions under a microscope. The system uses a six-input-three-output hexapole electromagnetic actuator to control the magnetic gradient force exerted on the probe and a three-dimensional vision-based motion tracking system to enable feedback control. The control system has three core functions that enables superior manipulation of the magnetic microprobe. The six-input-six-output closed-loop magnetic flux control significantly suppresses the effect of magnetic hysteresis and greatly increases the bandwidth of magnetic flux generation. The optimal flux allocation solves four issues in multipole magnetic force generation: redundancy; coupling; nonlinearity; and position-dependency. The position-dependent discrete-time motion control law determines the required force for stabilization and tracking. These three core functions have been implemented using a high-speed field programmable gate array (FPGA) system. Experiments have verified that the use of digital control technology, high-speed electronics, mathematical modeling, and real-time computation has achieved superior manipulation of a single magnetic microprobe in aqueous solutions.


  • Hall-Sensor-Based Magnetic Force Modeling and Inverse Modeling for Hexapole Electromagnetic Actuation

    by Fei Long, Ta-Min Meng, Jiunn-Jyh Wang, Chia-Hsiang Menq

    This article presents the Hall-sensor-based magnetic force modeling and inverse modeling for the hexapole electromagnetic actuation. Whereas mathematical models are derived for a specific hexapole electromagnetic actuating system, the results can be applied to other multipole electromagnetic actuators. Previously reported current-based force modeling and inverse modeling are subject to the combined hysteresis effect of multiple electromagnetic poles, resulting in significant error when being applied to produce magnetic force. To solve the challenge via direct measurement, Hall effect sensors are integrated into the hexapole system to measure the magnetic flux associated with individual magnetic poles. A Hall-sensor-based magnetic force model is then derived analytically, and the force gain and the associated voltage-flux gain matrix are determined via experimental calibration. The improved accuracy in force modeling is experimentally validated. Inverse modeling is then derived to render force production and to enable active control using the hexapole actuating system.


  • Open Access

    Personalized radioiodine therapy for thyroid cancer patients with known disease

    by Sissy M Jhiang, Peng Cheng, Fadi A Nabhan, Jennifer A Sipos, Chia-Hsiang Menq

    Radioactive iodine (RAI) 131I is a targeted therapy for patients with RAI-avid follicular cell-derived thyroid cancer. However, the responsiveness to 131I therapy varies among thyroid cancer patients mainly owing to differential RAI uptake and RAI radiosensitivity among patients’ lesions. A personalized approach to maximize 131I therapeutic efficacy is proposed based on recent scientific advances and future opportunities.


  • Optimal Current Allocation Rendering 3-D Magnetic Force Production in Hexapole Electromagnetic Actuation

    by Fei Long, Peng Cheng, Ta-Min Meng, Chia-Hsiang Menq

    This article presents the optimal current allocation and the magnetic force production associated with the hexapole electromagnetic actuation, wherein six electromagnets are used to control the magnetic field and exert the 3-D magnetic force on a specified microscopic magnetic particle in the 3-D workspace of the actuating system. It addresses four major issues in the inverse modeling of the multipole electromagnetic actuation, i.e., 1) redundancy; 2) coupling; 3) nonlinearity; and 4) position-dependency, and leads to the accurate and effective 3-D magnetic force production within the specified workspace. Specifically, the optimal inverse modeling of the hexapole electromagnetic actuation is derived to minimize the 2-norm of the $6 \times 1$ input current vector when applied to produce the desired 3-D magnetic force to propel the magnetic particle in aqueous solutions. The inverse model is implemented in a high-speed field programmable gate array system to realize the real-time current allocation, which is used to render the feedback stabilization of the magnetic trap. The accurate and effective 3-D force production through the optimal current allocation is experimentally validated.


  • Visual Tracking of Six-Axis Motion Rendering Ultraprecise Visual Servoing of Microscopic Objects

    by Peng Cheng, Chia-Hsiang Menq

    This paper presents visual tracking of 6-axis motion that renders ultra-precise visual servoing of microscopic objects. The principle of 3-axis out-of-plane motion tracking is based on three-degree-of-freedom (3-DOF) laterally sampled white light interferometry (LSWLI) and real-time unbiased non-linear parameter estimation of orientation-dependent interference fringes. A continuously shifting model of the warped shadow projection image of the object is derived and employed to achieve unbiased real-time image registration for 3-axis in-plane motion tracking. Processing of images and parameter estimation are synchronized with real-time image acquisition to realize 6-axis motion tracking. The ability of the proposed approach to eliminate measurement bias associated with previous approaches is validated through computer simulations. The visual motion tracking system is integrated with a six-axis compliant piezo stage to establish a 6-axis visual servo control system. Experimental results are presented and used to examine positioning resolution and to demonstrate superior precision achieved for long-range motion tracking.


  • Automated MicroSPECT/MicroCT Image Analysis of the Mouse Thyroid Gland

    by Peng Cheng, Brynn Hollingsworth, Daniel Scarberry, Daniel H. Shen, Kimerly Powell, Sean C. Smart, John Beech, Xiaochao Sheng, Lawrence S. Kirschner, Chia-Hsiang Menq, et al.

    Background: The ability of thyroid follicular cells to take up iodine enables the use of radioactive iodine (RAI) for imaging and targeted killing of RAI-avid thyroid cancer following thyroidectomy. To facilitate identifying novel strategies to improve 131 I therapeutic efficacy for patients with RAI refractory disease, it is desired to optimize image acquisition and analysis for preclinical mouse models of thyroid cancer. Methods: A customized mouse cradle was designed and used for microSPECT/CT image acquisition at 1 hour (t1) and 24 hours (t24) post injection of 123 I, which mainly reflect RAI influx/efflux equilibrium and RAI retention in the thyroid, respectively. FVB/N mice with normal thyroid glands and TgBRAF V600E mice with thyroid tumors were imaged. In-house CTViewer software was developed to streamline image analysis with new capabilities, along with display of 3D voxel-based 123 I gamma photon intensity in MATLAB. Results: The customized mouse cradle facilitates consistent tissue configuration among image acquisitions such that rigid body registration can be applied to align serial images of the same mouse via the in-house CTViewer software. CTViewer is designed specifically to streamline SPECT/CT image analysis with functions tailored to quantify thyroid radioiodine uptake. Automatic segmentation of thyroid volumes of interest (VOI) from adjacent salivary glands in t1 images is enabled by superimposing the thyroid VOI from the t24 image onto the corresponding aligned t1 image. The extent of heterogeneity in 123 I accumulation within thyroid VOIs can be visualized by 3D display of voxel-based 123 I gamma photon intensity. Conclusions: MicroSPECT/CT image acquisition and analysis for thyroidal RAI uptake is greatly improved by the cradle and the CTViewer software, respectively. Furthermore, the approach of superimposing thyroid VOIs from t24 images to select thyroid VOIs on corresponding aligned t1 images can be applied to studies in which the target tissue has differential radiotracer retention from surrounding tissues.


  • Open Access

    Modeling and calibrating nonlinearity and crosstalk in back focal plane interferometry for three-dimensional position detection

    by Peng Cheng, Sissy M. Jhiang, Chia-Hsiang Menq

    Back focal plane (BFP) interferometry is frequently used to detect the motion of a single laser trapped bead in a photonic force microscope (PFM) system. Whereas this method enables high-speed and high-resolution position measurement, its measurement range is limited by nonlinearity coupled with crosstalk in three-dimensional (3-D) measurement, and validation of its measurement accuracy is not trivial. This Letter presents an automated calibration system in conjunction with a 3-D quadratic model to render rapid and accurate calibration of the laser measurement system. An actively controlled three-axis laser steering system and a high-speed vision-based 3-D particle tracking system are integrated to the PFM system to enable rapid calibration. The 3-D quadratic model is utilized to correct for nonlinearity and crosstalk and, thus, extend the 3-D position detection volume of BFP interferometry. We experimentally demonstrated a 12-fold increase in detection volume when applying the method to track the motion of a 2.0 μm laser trapped polystyrene bead.

  • Design and Modeling of an Active Five-Axis Compliant Micromanipulator

    by G. R. Jayanth, C. H. Menq

    This paper presents the design and modeling of an active five-axis compliant micromanipulator whose tip orientation can be independently controlled by large angles about two axes and the tip-position can be controlled in three dimensions. These features enable precise control of the contact point of the tip and the tip–sample interaction forces with three-dimensional nanoscale objects, including those features that are conventionally inaccessible. Control of the tip-motion is realized by means of electromagnetic actuation combined with a novel kinematic and structural design of the micromanipulator, which, in addition, also ensures compatibility with existing high-resolution motion-measurement systems. The design and analysis of the manipulator structure and those of the actuation system are first presented. Quasi-static and dynamic lumped-parameter (LP) models are then derived for the five-axis compliant micromanipulator. Finite element (FE) analysis is employed to validate these models, which are subsequently used to study the effects of tip orientation on the mechanical characteristics of the five-axis micromanipulator. Finally, a prototype of the designed five-axis manipulator is fabricated by means of focused ion-beam milling (FIB).