Ika Dewi Wijayanti has a total of 41 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Ga³⁺-Induced Amorphization and GO-Assisted Interfacial Ion Transport in PVA-Based Polymer Electrolyte Systems

    by Nur Laila Hamidah, Enrico Gabriel Izzul Haq, Husna Sabita, Gregory Hope Soegiantoro, Gunawan Nugroho, Tasya Yusiasfa Christnantasari, Ika Dewi Wijayanti, Adi Darmawan, Moh. Adhib Ulil Absor, Rugi Vicente D.C. Rubi

    The development of solid polymer electrolyte systems with improved ion transport and interfacial compatibility remains essential for advancing safe solid-state supercapacitors. In this study, a polyvinyl alcohol–glycerol (PVA-G) polymer electrolyte doped with gallium nitrate (Ga(NO₃)₃) was combined with graphene oxide (GO)-modified activated carbon electrodes to investigate the coupled effects of polymer amorphization and interfacial ion transport behavior. The incorporation of trivalent Ga³⁺ ions disrupted intermolecular hydrogen bonding within the PVA matrix, promoting structural amorphization and enhanced polymer chain mobility. X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), and differential scanning calorimetry (DSC) analyses confirmed reduced crystallinity, broadened O–H interactions, and decreased glass transition temperature after salt addition. The optimized electrolyte containing 15 wt% Ga(NO₃)₃ exhibited an ionic conductivity of 6.0 × 10⁻⁴ S cm⁻¹ at room temperature and reached 1.0 × 10⁻³ S cm⁻¹ at 80 °C, following thermally activated ion transport behavior. Meanwhile, GO incorporation into activated carbon electrodes improved interfacial contact and reduced electrode resistance by filling interparticle voids and introducing oxygen-containing functional groups that facilitated ion accessibility at the electrode–electrolyte interface. Electrochemical impedance spectroscopy revealed a substantial reduction in equivalent series resistance from 10,820 Ω to 1,644 Ω after GO addition. The optimized solid-state supercapacitor exhibited a specific capacitance of 6.07 F g⁻¹ with stable charge–discharge behavior. These findings demonstrate that the synergistic combination of Ga³⁺-induced polymer amorphization and GO-assisted interface modification plays an important role in improving ion transport characteristics and interfacial compatibility in PVA-based solid polymer electrolyte systems.

  • Open Access

    Investigating short-term overheating failures in secondary superheater outlet of boiler steam power plant

    by Ika Dewi Wijayanti, Sastya Adzani Syahbania, Indra Sidharta, Sutikno, Ubaidillah Ubaidillah


  • Open Access

    Correlation between diffusion and kinetic behaviour of metal hydride battery: voltammetry and impedance analyses

    by Ika Dewi Wijayanti, Delia Salsabila Putri, Farhan Dzikriansyah, Indra Sidharta, Sutikno Sutikno

    The performance of metal hydride batteries depends on their electrochemical and kinetic behaviour, which varies with the state of charge (SoC). This study explores these characteristics in nickel-metal hydride batteries with A2B7 and AB5 electrodes, focusing on how SoC influences ion diffusion and charge transfer kinetics of the batteries. Electro¬chemical impedance spectroscopy and cyclic voltammetry (CV) were used to analyse these behaviours, while X-ray diffraction provided structural insights and scanning electron microscopy proposed morphological concepts. Results reveal a positive correlation between SoC and both diffusion and kinetic behaviour. The value of fitting resistances decreases as SoC increases, reaching a minimum at 100 % SoC, where hydrogen diffusion is optimized. CV data supports this phenomenon, showing a more negative peak cathodic current (Ip,c) at higher SoC, indicating improved kinetics likely due to enhanced ion availability. Additionally, voltage window analysis showed maximum hydrogen storage at 100 % SoC for AB5 and 50 % for A2B7. Structurally, larger particle sizes and crystallites at higher SoC correlate with increased hydrogen desorption capacity. A2B7 exhibited superior diffusion kinetics, while AB5 demonstrated better discharge behaviour, highlighting how SoC-dependent diffusion and kinetics impact Ni-MH performance.


  • Open Access

    Optimalisasi Proses Pemanasan pada Pengolahan Limbah Sampah Plastik di Robries

    by Ika Dewi Wijayanti, Putu Suwarta, Sutikno Sutikno, Fahmi Mubarok, H.C. Kis Agustin, Suwarno Suwarno, Wahyu Wijanarko, Indra Sidharta

    Robries adalah perusahaan daur ulang limbah plastik di Surabaya yang didirikan pada tahun 2018 oleh alumni Desain Produk ITS. Perusahaan ini bertujuan mengurangi limbah termoplastik dengan mengolahnya menjadi perabot rumah tangga seperti bangku, lemari, dan pot bunga, serta tutup botol dan wadah kosmetik. Namun, beberapa masalah dalam produk daur ulangnya, seperti penyusutan yang tidak terkontrol, dimensi produk yang tidak konsisten serta void, menyebabkan Robries kesulitan untuk memasarkan produknya ke luar negeri. Berdasarkan pengamatan Tim Departemen Teknik Mesin (DTM) ITS di pabrik, diketahui bahwa selama proses pencetakan berlangsung, distribusi temperatur pada peralatan oven yang ada saat ini tidak merata sehingga menyebabkan penyusutan dan dimensi produk yang tidak konsisten. Langkah yang dilakukan oleh tim DTM ITS adalah dengan melakukan pengukuran temperatur dan studi peralatan oven yang ada lalu solusi yang ditawarkan adalah (1) memastikan temperatur pemanasan di oven sudah merata sebelum memasukkan limbah termoplastik dan (2) re-design peralatan oven yang ada saat ini dengan menambahkan sistem pendinginan untuk memastikan distribusi panas di dalam oven merata sehingga produk memiliki dimensi yang konsisten dan cacat seminimal mungkin. Cacat yang dihasilkan lebih sedikit setelah menggunakan kedua solusi tersebut sehingga dapat disimpulkan kualitas produk daur ulang plastik telah ditingkatkan.


  • Open Access

    A Composite of Hydrogel Alginate/PVA/r-GO for Scaffold Applications with Enhanced Degradation and Biocompatibility Properties

    by Amaliya Rasyida, Salma Halimah, Ika Dewi Wijayanti, Sigit Tri Wicaksono, Haniffudin Nurdiansah, Yohannes Marudut Tua Silaen, Yatim Lailun Ni’mah, Hosta Ardhyananta, Agung Purniawan

    We reported in this study the interrelation between the addition of 0.4, 0.8, 1.2, and 1.6 wt. % reduced graphene oxide (r-GO) into PVA/Alginate and their degradation and biocompatibility properties. The r-GO was synthesized by using the Hummer’s method. A crosslinker CaSO4 was added to prepare Alginate/PVA/r-GO Hydrogel composite. A Field Emission in Lens (FEI)-scanning electron microscopy (SEM), along with X-ray energy dispersive spectroscopy (EDS), was performed, characterizing the morphology of the composite. A compressive test was conducted, determining the mechanical properties of the composite with the highest achieved 0.0571 MPa. Furthermore, in vitro cytotoxicity was conducted to determine the biocompatibility properties of the studied composite. An MTT assay was applied to measure cell viability. In general, the presence of r-GO was found to have no significant effect on the morphology of the hydrogel. Indeed, adding 0.4% r-GO to the PVA/Alginate increased the cell viability up to 122.26 ± 0.93, indicating low toxicity. The studied composites have almost no changes in weight and shape, which proves that low degradation occurred in addition to this after 28 days of immersion in saline phosphate buffer solution. In conclusion, achieving minimal degradation and outstanding biocompatibility lead to PVA/Alginate/r-GO hydrogel composites being the most attractive materials for tissue engineering applications.


  • Open Access

    Failure analysis of the leakage at boiler bottom wall tube of steam power plant

    by I. D. Wijayanti, H. C. K. Agustin, Arif Hariyadi

    In order to maintain the availability of electricity supply, a failure at the power plant is mandatory to be prevented. If damage has occurred, analysis of the root cause of failure must be prioritized to resolve the problem and prevent further damage. One of the important units in a power plant is a boiler that has a role as a steam generator producing the steam by changing the water in the liquid to the vapor phase. The quality of the (feed) water becomes one crucial factor in determining the lifetime of a boiler. Moreover, some factors related to the process variable control such as velocity, temperature, pressure, and flow rate of fluid should follow the specified design. Otherwise, the failure can occur, resulting in the unit shutting down, thus stopping the electric production. In this paper, the mechanism of the leakages that occurred at boiler bottom wall tubes of the steam power plant was investigated. Quality of (feed) water and several factors associated with the leakages such as temperature, pressure, and fluid characteristic are mainly considered the suspect contributing to the damage. Further to this, macro-and microstructural observations at the leaked tubes as the physical analysis were done. Analysis of chemical composition was performed to the (feed) water. Other factors concerned with the failure were also observed to validate the root cause analysis and mechanism of the leakages. Chemical analysis of (feed) water shows that the excess content of hydrazine (N2H4) as an inhibitor of corrosion is 100 times more than specified representing the low-quality level of (feed) water which significantly influences the aggressiveness of the water. In addition to this, an intentional turbulence of the flow rate of (feed) water shown by having a Reynold number of 33,000 together with the contaminated (feed) water significantly increases the risk of failure at the inner tube. Macro observation exhibits a sectional reduction on the upper curve radius at the leaked tubes indicating that a loss of product reaction between the outer tube surface with a suspicious variable occurred during the operation. Moreover, a damage to the protective magnetite layer was particularly found around the leakage denoting that a local failure happened at the inner surface tube. On the other hand, micro observation shows a local plastic deformation implying an increase of high local temperature around the leaked tubes. To conclude, the tube leakages are mainly resulted from the collaboration of suspicious factors originating from the ambient environment on both sides of the tubes. Indeed, the low level of water quality, the high turbulence of flow rate, and the increasing of local temperature during operation at inner tubes successfully caused the erosion corrosion. While the suspicious factor at outer tube, such as the fuel, led to induce the pitting corrosion. In this case, both corrosions are responsible factors to encourage the failure.


  • The electrochemical performance of melt-spun C14-Laves type Ti Zr-based alloy

    by Ika Dewi Wijayanti, Live Mølmen, Roman V. Denys, Jean Nei, Stéphane Gorsse, Kwo Young, Matylda N. Guzik, Volodymyr Yartys


  • Morphology of Crown Tube Austenitic Stainless Steel TP316 HTF Failure

    by Helena Carolina Kis Agustin, Ika Dewi Wijayanti, Rakhmat Satrio Wibowo

    High temperature operations of flares often give the serious problems to its crown tube. Especially the materials that used are stainless steel. The locations of disposal gas combustion at the crown become the primary aspect of flare operation. The macro structure of failed crown tube was found to have the fissure on its edge, which has the variation of appearances. The chance of materials to react with high temperature combustion contributes to the differences of tube crown color that failed. The former and the later appearances indicated the mode of failure. This paper observes the locations effect of disposal gas combustion to the failure of crown tube color and fissure mode. Visual examination was implemented to figure out the effect of the environment to the crown tube. SEM data also should be considered to convince the phases that came out from the interaction between crown tube and high temperature combustion. The difference of temper color of failure crown was found on the inner and outer surface. Unevenly heat source from the inner surface caused the ignition force from the inner surface of crown tube that led the initial deformation for the crown.