Naruhiro Matsufuji
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Naruhiro Matsufuji has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
Tatsuaki Kanai
Department of Accelerator and Medical Physics, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Japan
3 shared publicationsAkifumi Fukumura
Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, 263-8555 Chiba, Japan
2 shared publicationsMasataka Komori
Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, 263-8555 Chiba, Japan
2 shared publicationsToshiyuki Kohno
Department of Energy Science, Tokyo Institute of Technology, 226-8502 Yokohama, Japan
2 shared publicationsEriko Urakabe
Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, 263-8555 Chiba, Japan
1 shared publicationHirohiko Tsujii
Hospital, Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Japan
1 shared publication
Latest Publications
- 1 January 2016
- Published by Springer Nature
- p. 157-168
Modeling of Biological Effect of Charged Particles for C-Ion RT
- 1 January 2016
- Published by Springer Nature
- p. 157-168
Modeling of Biological Effect of Charged Particles for C-Ion RT
- Open Access
- 7 April 2010
- Published by Springer Nature in BMC Cancer
- Vol. 10 (1) , 127
Focal dose escalation using FDG-PET-guided intensity-modulated radiation therapy boost for postoperative local recurrent rectal cancer: a planning study with comparison of DVH and NTCP
To evaluate the safety of focal dose escalation to regions with standardized uptake value (SUV) >2.0 using intensity-modulated radiation therapy (IMRT) by comparison of radiotherapy plans using dose-volume histograms (DVHs) and normal tissue complication probability (NTCP) for postoperative local recurrent rectal cancer
- 7 April 2010
- Published by Springer Nature in BMC Cancer
- Vol. 10 (1) , 127
Open AccessFocal dose escalation using FDG-PET-guided intensity-modulated radiation therapy boost for postoperative local recurrent rectal cancer: a planning study with comparison of DVH and NTCP
To evaluate the safety of focal dose escalation to regions with standardized uptake value (SUV) >2.0 using intensity-modulated radiation therapy (IMRT) by comparison of radiotherapy plans using dose-volume histograms (DVHs) and normal tissue complication probability (NTCP) for postoperative local recurrent rectal cancer
- Open Access
- 1 January 2007
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 48 (Suppl.A) , A81-A86
Specification of Carbon Ion Dose at the National Institute of Radiological Sciences (NIRS)
The clinical dose distributions of therapeutic carbon beams, currently used at NIRS HIMAC, are based on in-vitro Human Salivary Gland (HSG) cell surv
- 1 January 2007
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 48 (Suppl.A) , A81-A86
Open AccessSpecification of Carbon Ion Dose at the National Institute of Radiological Sciences (NIRS)
The clinical dose distributions of therapeutic carbon beams, currently used at NIRS HIMAC, are based on in-vitro Human Salivary Gland (HSG) cell surv
- 6 July 2005
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 50 (14) , 3393-3403
Spatial fragment distribution from a therapeutic pencil-like carbon beam in water
The latest heavy ion therapy tends to require information about the spatial distribution of the quality of radiation in a patient's body in order to make the best use of any potential advantage of swift heavy ions for the therapeutic treatment of a tumour. The deflection of incident particles is described well by Molière's multiple-scattering theory of primary particles; however, the deflection of projectile fragments is not yet thoroughly understood. This paper reports on our investigation of the spatial distribution of fragments produced from a therapeutic carbon beam through nuclear reactions in thick water. A DeltaE-E counter telescope system, composed of a plastic scintillator, a gas-flow proportional counter and a BGO scintillator, was rotated around a water target in order to measure the spatial distribution of the radiation quality. The results revealed that the observed deflection of fragment particles exceeded the multiple scattering effect estimated by Molière's theory. However, the difference can be sufficiently accounted for by considering one term involved in the multiple-scattering formula; this term corresponds to a lateral 'kick' at the point of production of the fragment. This kick is successfully explained as a transfer of the intra-nucleus Fermi momentum of a projectile to the fragment; the extent of the kick obeys the expectation derived from the Goldhaber model.
- 6 July 2005
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 50 (14) , 3393-3403
Spatial fragment distribution from a therapeutic pencil-like carbon beam in water
The latest heavy ion therapy tends to require information about the spatial distribution of the quality of radiation in a patient's body in order to make the best use of any potential advantage of swift heavy ions for the therapeutic treatment of a tumour. The deflection of incident particles is described well by Molière's multiple-scattering theory of primary particles; however, the deflection of projectile fragments is not yet thoroughly understood. This paper reports on our investigation of the spatial distribution of fragments produced from a therapeutic carbon beam through nuclear reactions in thick water. A DeltaE-E counter telescope system, composed of a plastic scintillator, a gas-flow proportional counter and a BGO scintillator, was rotated around a water target in order to measure the spatial distribution of the radiation quality. The results revealed that the observed deflection of fragment particles exceeded the multiple scattering effect estimated by Molière's theory. However, the difference can be sufficiently accounted for by considering one term involved in the multiple-scattering formula; this term corresponds to a lateral 'kick' at the point of production of the fragment. This kick is successfully explained as a transfer of the intra-nucleus Fermi momentum of a projectile to the fragment; the extent of the kick obeys the expectation derived from the Goldhaber model.
- 20 May 2003
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 48 (11) , 1605-1623
Influence of fragment reaction of relativistic heavy charged particles on heavy-ion radiotherapy
The production of projectile fragments is one of the most important, but not yet perfectly understood, problems to be considered when planning for the utilization of high-energy heavy charged particles for radiotherapy. This paper reports our investigation of the fragments' fluence and linear energy transfer (LET) spectra produced from various incident ions using an experimental approach to reveal these physical qualities of the beams. Polymethyl methacrylate, as a substitute for the human body, was used as a target. A deltaE-E counter telescope with a plastic scintillator and a BGO scintillator made it possible to identify the species of fragments based on differences of various elements. By combining a gas-flow proportional counter with a counter telescope system, LET spectra as well as fluence spectra of the fragments were derived for each element down from the primary particles to hydrogen. Among them, the information on hydrogen and helium fragments was derived for the first time. The result revealed that the number of light fragments, such as hydrogen and helium, became larger than the number of primaries in the vicinity of the range end. However, the greater part of the dose delivered to a cell was still governed by the primaries. The calculated result of a simulation used for heavy-ion radiotherapy indicated room for improving the reaction model.
- 20 May 2003
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 48 (11) , 1605-1623
Influence of fragment reaction of relativistic heavy charged particles on heavy-ion radiotherapy
The production of projectile fragments is one of the most important, but not yet perfectly understood, problems to be considered when planning for the utilization of high-energy heavy charged particles for radiotherapy. This paper reports our investigation of the fragments' fluence and linear energy transfer (LET) spectra produced from various incident ions using an experimental approach to reveal these physical qualities of the beams. Polymethyl methacrylate, as a substitute for the human body, was used as a target. A deltaE-E counter telescope with a plastic scintillator and a BGO scintillator made it possible to identify the species of fragments based on differences of various elements. By combining a gas-flow proportional counter with a counter telescope system, LET spectra as well as fluence spectra of the fragments were derived for each element down from the primary particles to hydrogen. Among them, the information on hydrogen and helium fragments was derived for the first time. The result revealed that the number of light fragments, such as hydrogen and helium, became larger than the number of primaries in the vicinity of the range end. However, the greater part of the dose delivered to a cell was still governed by the primaries. The calculated result of a simulation used for heavy-ion radiotherapy indicated room for improving the reaction model.