Benjamin J. Brown
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Benjamin J. Brown has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Gang Xiao
Brown University
6 shared publications - H. Minh Cao
Brown University
3 shared publications - Liam K. Mitchell
Brown University
3 shared publications - Vineetha S. Bheemarasetty
Brown University
3 shared publications A. Herschelman
The Johns Hopkins University Applied Physics Laboratory , 11100 Johns Hopkins Road, Laurel, Maryland 20723, USA
1 shared publication- Alexander Zaslavsky
School of Engineering, Brown University, Providence, RI, USA
1 shared publication
Latest Publications
- 5 October 2026
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 140 (13)
Intermittent Lorentzian noise in magnetic tunnel junctions under voltage-bias stress
For magnetic tunnel junction (MTJ) sensors used in long-term operation, the noise profile must remain stable under voltage bias. Low-frequency 1/f noise in MTJs is often measured over a limited time window and can contain a Lorentzian component from random telegraph noise. Here, we continuously tracked the noise spectra of single micrometer-scale MgO-based MTJs for 100–500 h under DC bias at room temperature and zero applied field. The spectra show a smooth 1/fβ background, but the Lorentzian component is intermittent: it can appear, disappear, and drift in corner frequency under the same bias condition. In the devices studied, this contribution raises the local noise power spectral density by up to ηmax ≈ 6.0 and is present for 3.6%–71% of the measurement record. Resistance–field measurements on one junction show no irreversible change in magnetic response across a Lorentzian-active period. These results reveal reversible, time-dependent Lorentzian-noise states under electrical stress, which may originate from barrier defect dynamics or magnetic configurational fluctuations. Consequently, single-shot spectra are insufficient to capture the intermittent noise states that govern long-term MTJ performance.
- 5 October 2026
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 140 (13)
Intermittent Lorentzian noise in magnetic tunnel junctions under voltage-bias stress
For magnetic tunnel junction (MTJ) sensors used in long-term operation, the noise profile must remain stable under voltage bias. Low-frequency 1/f noise in MTJs is often measured over a limited time window and can contain a Lorentzian component from random telegraph noise. Here, we continuously tracked the noise spectra of single micrometer-scale MgO-based MTJs for 100–500 h under DC bias at room temperature and zero applied field. The spectra show a smooth 1/fβ background, but the Lorentzian component is intermittent: it can appear, disappear, and drift in corner frequency under the same bias condition. In the devices studied, this contribution raises the local noise power spectral density by up to ηmax ≈ 6.0 and is present for 3.6%–71% of the measurement record. Resistance–field measurements on one junction show no irreversible change in magnetic response across a Lorentzian-active period. These results reveal reversible, time-dependent Lorentzian-noise states under electrical stress, which may originate from barrier defect dynamics or magnetic configurational fluctuations. Consequently, single-shot spectra are insufficient to capture the intermittent noise states that govern long-term MTJ performance.
- Open Access
- 2 July 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (26) , 265002
Reassessing magnetic tunnel junction detectability for ultrasensitive sensing using small-field sensitivity and Jiles–Atherton modeling
Magnetic tunnel junction (MTJ) sensors are attractive for detecting extremely small magnetic fields, yet their performance is often quantified using sensitivities derived from major loops or larger-field minor loops which inherently include hysteretic contributions. As a result, these conventional metrics significantly overestimate detectability by including irreversible processes that vanish in the small-field limit. Here, we systematically measure the low-field response of uniaxial MTJs under both ac and dc magnetic excitation and demonstrate a distinct transition from hysteretic to fully reversible behavior as the field amplitude is reduced. By adapting the Jiles–Atherton model to analyze MTJ conductance, we establish a unified framework that captures magnetization processes down to nanotesla range, yielding quantitative parameters that resolve reversible and irreversible dynamics with excellent fidelity. In the reversible regime, the sensitivity converges to a constant value of 0.55%Oe − 1 , defining an intrinsic, history-independent response of the MTJ. Importantly, this is less than half of the 1.2%Oe − 1 obtained from higher-field minor loop estimates but is physically representative of the sensing response in low-field operation. The constant and intrinsic sensitivity corresponds to the true value of detectability, confirmed by noise spectral density measurements under low-field ac excitation. These results establish a quantitative framework for MTJ evaluation that emphasizes intrinsic, hysteresis-free performance, providing both a realistic basis for calculating field detectability and a general methodology for probing magnetization in micron- and nano-scale ferromagnets.
- 2 July 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (26) , 265002
Open AccessReassessing magnetic tunnel junction detectability for ultrasensitive sensing using small-field sensitivity and Jiles–Atherton modeling
Magnetic tunnel junction (MTJ) sensors are attractive for detecting extremely small magnetic fields, yet their performance is often quantified using sensitivities derived from major loops or larger-field minor loops which inherently include hysteretic contributions. As a result, these conventional metrics significantly overestimate detectability by including irreversible processes that vanish in the small-field limit. Here, we systematically measure the low-field response of uniaxial MTJs under both ac and dc magnetic excitation and demonstrate a distinct transition from hysteretic to fully reversible behavior as the field amplitude is reduced. By adapting the Jiles–Atherton model to analyze MTJ conductance, we establish a unified framework that captures magnetization processes down to nanotesla range, yielding quantitative parameters that resolve reversible and irreversible dynamics with excellent fidelity. In the reversible regime, the sensitivity converges to a constant value of 0.55%Oe − 1 , defining an intrinsic, history-independent response of the MTJ. Importantly, this is less than half of the 1.2%Oe − 1 obtained from higher-field minor loop estimates but is physically representative of the sensing response in low-field operation. The constant and intrinsic sensitivity corresponds to the true value of detectability, confirmed by noise spectral density measurements under low-field ac excitation. These results establish a quantitative framework for MTJ evaluation that emphasizes intrinsic, hysteresis-free performance, providing both a realistic basis for calculating field detectability and a general methodology for probing magnetization in micron- and nano-scale ferromagnets.
- 6 February 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (5) , 055004
Contrasting uniaxial and vortex-state magnetic tunnel junction sensors: sensitivity and tunnel magnetoresistance at low temperatures
Uniaxial and vortex-state magnetic tunnel junction (MTJ) sensors represent two widely used device configurations for magnetic field detection. Uniaxial sensors remain the prevalent design due to their high sensitivity and straightforward operation, while vortex-state sensors are gaining popularity for their intrinsic non-hysteretic response to external perturbations. Each architecture offers distinct advantages and trade-offs, yet their relative performance under cryogenic conditions has not been systematically characterized. Such knowledge is essential for emerging low-temperature applications, particularly in quantum device metrology and superconducting electronics. In this work, we report the first systematic temperature-dependent comparison of uniaxial and vortex-state MTJ sensors over 10–300 K. In addition to the parallel, antiparallel, and zero-field conductance states, we extract the low-field sensitivity as a function of temperature. Both sensor types exhibit a pronounced increase in their overall tunnel magnetoresistance (TMR) ratio at low temperatures. However, uniaxial MTJs show a 17% reduction in the zero-field sensitivity, driven by a more than twofold rise in coercivity. In contrast, vortex-state MTJs exhibit a nearly constant sensing response over the entire temperature range, showing only a 7% increase of sensitivity at 10 K from 300 K. Additionally, the vortex-state MTJ achieves a temperature coefficient of sensitivity of −376 ppm K −1 at room temperature and −21 ppm K −1 at low temperatures, indicating highly stable and enhanced performance in cryogenic regimes. These results demonstrate that TMR alone does not govern sensing performance and underscore the decisive role of magnetization reversal dynamics and device geometry. Vortex-state MTJs thus emerge as robust candidates for cryogenic sensing applications requiring thermally stable and reliable field detection with diminished hysteresis.
- 6 February 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (5) , 055004
Contrasting uniaxial and vortex-state magnetic tunnel junction sensors: sensitivity and tunnel magnetoresistance at low temperatures
Uniaxial and vortex-state magnetic tunnel junction (MTJ) sensors represent two widely used device configurations for magnetic field detection. Uniaxial sensors remain the prevalent design due to their high sensitivity and straightforward operation, while vortex-state sensors are gaining popularity for their intrinsic non-hysteretic response to external perturbations. Each architecture offers distinct advantages and trade-offs, yet their relative performance under cryogenic conditions has not been systematically characterized. Such knowledge is essential for emerging low-temperature applications, particularly in quantum device metrology and superconducting electronics. In this work, we report the first systematic temperature-dependent comparison of uniaxial and vortex-state MTJ sensors over 10–300 K. In addition to the parallel, antiparallel, and zero-field conductance states, we extract the low-field sensitivity as a function of temperature. Both sensor types exhibit a pronounced increase in their overall tunnel magnetoresistance (TMR) ratio at low temperatures. However, uniaxial MTJs show a 17% reduction in the zero-field sensitivity, driven by a more than twofold rise in coercivity. In contrast, vortex-state MTJs exhibit a nearly constant sensing response over the entire temperature range, showing only a 7% increase of sensitivity at 10 K from 300 K. Additionally, the vortex-state MTJ achieves a temperature coefficient of sensitivity of −376 ppm K −1 at room temperature and −21 ppm K −1 at low temperatures, indicating highly stable and enhanced performance in cryogenic regimes. These results demonstrate that TMR alone does not govern sensing performance and underscore the decisive role of magnetization reversal dynamics and device geometry. Vortex-state MTJs thus emerge as robust candidates for cryogenic sensing applications requiring thermally stable and reliable field detection with diminished hysteresis.
- Open Access
- 27 October 2025
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 635
Annealing and thickness optimisation in CoZrNb and FeSiBNbCu thin films for low-frequency magnetic flux concentrators
- 27 October 2025
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 635
Open AccessAnnealing and thickness optimisation in CoZrNb and FeSiBNbCu thin films for low-frequency magnetic flux concentrators
- Open Access
- 23 September 2025
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 24 (3)
High magnetic sensitivity via large-diameter-vortex stability in magnetic tunnel junctions through controlled anisotropy
Magnetic-annealing-induced uniaxial anisotropy is shown to influence vortex formation in magnetic tunnel junction (MTJ) free layers of various diameters, with micromagnetic simulations demonstrating a threshold for single-vortex formation that exhibits an inverse diameter dependence. Angular M - H curves were measured for MTJ multilayers under different annealing conditions, and reveal that a two-step orthogonal magnetic annealing process reduces the uniaxial anisotropy in the free layer from 1040 J / m 3 to 130 J / m 3 . This reduction in anisotropy allows for vortex formation in MTJ sensors as large as 40 μ m . Increasing the MTJ diameter leads to an enhancement of magnetic sensitivity up to 2.80 % / Oe with the conventional definition, or 1.78 % / Oe via an ac sensitivity measurement that verifies the nonhysteretic response. This result demonstrates an eightfold increase in vortex-MTJ sensitivity, compared with standard MTJs that have diameters limited to 5 μ m , and this work provides the foundation for highly sensitive vortex-MTJ-based sensors for applications that require a nonhysteretic, ultrasensitive response.
- 23 September 2025
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 24 (3)
Open AccessHigh magnetic sensitivity via large-diameter-vortex stability in magnetic tunnel junctions through controlled anisotropy
Magnetic-annealing-induced uniaxial anisotropy is shown to influence vortex formation in magnetic tunnel junction (MTJ) free layers of various diameters, with micromagnetic simulations demonstrating a threshold for single-vortex formation that exhibits an inverse diameter dependence. Angular M - H curves were measured for MTJ multilayers under different annealing conditions, and reveal that a two-step orthogonal magnetic annealing process reduces the uniaxial anisotropy in the free layer from 1040 J / m 3 to 130 J / m 3 . This reduction in anisotropy allows for vortex formation in MTJ sensors as large as 40 μ m . Increasing the MTJ diameter leads to an enhancement of magnetic sensitivity up to 2.80 % / Oe with the conventional definition, or 1.78 % / Oe via an ac sensitivity measurement that verifies the nonhysteretic response. This result demonstrates an eightfold increase in vortex-MTJ sensitivity, compared with standard MTJs that have diameters limited to 5 μ m , and this work provides the foundation for highly sensitive vortex-MTJ-based sensors for applications that require a nonhysteretic, ultrasensitive response.
- Open Access
- 27 June 2025
- Published by American Physical Society (APS) in Physical Review B
- Vol. 111 (21)
Shubnikov–de Haas oscillations in half-metallic ferromagnetic epitaxial filmsWe present a study of the low-temperature, high-field magnetotransport behavior of epitaxially grown CrO 2 thin films on (100) TiO 2 substrates. Electron transport measurements confirm high sample quality, with a residual resistivity ratio as large as 45. A logarithmic fit of the low-temperature regime yields a T 4.5 power law, indicative of the elusive double-magnon scattering in half-metallic ferromagnets. Angle-dependent anisotropic magnetoresistance (AMR) measurements reveal a large projected density of states along [001] with a maximum AMR value of 2.4%. Pronounced, axis-dependent Shubnikov–de Haas (SdH) oscillations are observed in the longitudinal magnetoresistance (MR), with discrete Landau levels mapped at various tilt angles of the magnetic field. Their angular dependence follows a 1 / cos θ relation pointing to a highly anisotropic Fermi surface, and amplitude scaling adheres closely to the thermodynamic Lifshitz-Kosevich formalism. The out-of-plane MR reaches 6.58%, the largest reported for CrO 2 thin films. Notably, this study presents an observation of SdH oscillations in a half-metallic oxide with near-perfect spin polarization, a significant advancement in the field of spintronics.
- 27 June 2025
- Published by American Physical Society (APS) in Physical Review B
- Vol. 111 (21)
Open AccessShubnikov–de Haas oscillations in half-metallic ferromagnetic epitaxial filmsWe present a study of the low-temperature, high-field magnetotransport behavior of epitaxially grown CrO 2 thin films on (100) TiO 2 substrates. Electron transport measurements confirm high sample quality, with a residual resistivity ratio as large as 45. A logarithmic fit of the low-temperature regime yields a T 4.5 power law, indicative of the elusive double-magnon scattering in half-metallic ferromagnets. Angle-dependent anisotropic magnetoresistance (AMR) measurements reveal a large projected density of states along [001] with a maximum AMR value of 2.4%. Pronounced, axis-dependent Shubnikov–de Haas (SdH) oscillations are observed in the longitudinal magnetoresistance (MR), with discrete Landau levels mapped at various tilt angles of the magnetic field. Their angular dependence follows a 1 / cos θ relation pointing to a highly anisotropic Fermi surface, and amplitude scaling adheres closely to the thermodynamic Lifshitz-Kosevich formalism. The out-of-plane MR reaches 6.58%, the largest reported for CrO 2 thin films. Notably, this study presents an observation of SdH oscillations in a half-metallic oxide with near-perfect spin polarization, a significant advancement in the field of spintronics.
- Open Access
- 1 March 2019
- Published by AIP Publishing in AIP Advances
- Vol. 9 (3) , 035123
Approaches for single channel large area silicon photomultiplier array readout
We present the results of experiments applying a large area tiled array of silicon photomultipliers (SiPM) to gamma ray spectroscopy with 50.8 mm diameter NaI(Tl) and CsI(Tl) scintillators and 25.4 mm diameter CeBr3. These scintillators are many times larger than an individual SiPM, the largest of which are 36 mm2 at present. This work compares two methods of summing 64 SiPMs into a single output signal for use with standard charge integration electronics. The methods are a straightforward passive method, which simply combines all anode and cathodes together, and an active method, which employs high bandwidth op-amps in a summing topology. Comparisons are also made to a high quantum efficiency photomultiplier tube (PMT) for both resolution and pulse shape. Resolution and noise floor are satisfactorily comparable to the PMT from 21 keV to 2614 keV. The passive method provides the most straightforward approach, and slightly better energy resolution than the active method. The active method shows a substantially faster pulse rise time and undistorted fall time compared to the passive method.
- 1 March 2019
- Published by AIP Publishing in AIP Advances
- Vol. 9 (3) , 035123
Open AccessApproaches for single channel large area silicon photomultiplier array readout
We present the results of experiments applying a large area tiled array of silicon photomultipliers (SiPM) to gamma ray spectroscopy with 50.8 mm diameter NaI(Tl) and CsI(Tl) scintillators and 25.4 mm diameter CeBr3. These scintillators are many times larger than an individual SiPM, the largest of which are 36 mm2 at present. This work compares two methods of summing 64 SiPMs into a single output signal for use with standard charge integration electronics. The methods are a straightforward passive method, which simply combines all anode and cathodes together, and an active method, which employs high bandwidth op-amps in a summing topology. Comparisons are also made to a high quantum efficiency photomultiplier tube (PMT) for both resolution and pulse shape. Resolution and noise floor are satisfactorily comparable to the PMT from 21 keV to 2614 keV. The passive method provides the most straightforward approach, and slightly better energy resolution than the active method. The active method shows a substantially faster pulse rise time and undistorted fall time compared to the passive method.