CCClifton M. Carey

Clifton M. Carey

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Clifton M. Carey has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Improved contact x-ray microradiographic method to measure mineral density of hard dental tissues

    by B. D. Schmuck, C. M. Carey

    Contact x-ray microradiography is the current gold standard for measuring mineral densities of partially demineralized tooth specimens. The x-ray sensitive film specified in the last J Res NIST publication on the subject is no longer commercially available. Objectives: Develop a new microradiographic method by identifying a commercially available film with greater than 3000 lines per millimeter resolution, which is sensitive to x rays, and develop correct film processing for x-ray microradiographic application. Methods: A holographic film was identified as a potential replacement film. Proper exposure was determined utilizing a thick nickel plate to create test-strips. Film development was bracketed around manufacturer suggestions. Film linearity was determined with aluminum step-wedges. Microradiographs of 100 mu m thick tooth sections, before and after acidic challenges, were a final test for film. Magnified images were captured with a digital microscope camera with 0.305 micrometers per pixel resolution. Results: The appropriate film exposure was 30 min at 80 kV(p) and 3 mA with a development time of 2 min. Step-wedge experiments show the system to be linear in terms of pixel intensities with respect to x-ray attenuation for normalized pixel intensity values that are 10 % to 90 % of full scale (r(2) = 0.997) which encompasses the full exposure region of tooth tissue. Enamel sections were analyzed and show distinctive differences between erosion and demineralization. The image capture device resolution of 0.305 micrometers per pixel limits the system resolution. Conclusion: Use of the identified holographic film when combined with the described processing modifications has resulted in an improved x-ray microradiographic method for the measurement of mineral density of dental hard tissues. The method described can be further improved by using a higher resolution digitization system. The method is appropriate for quantitatively measuring changes in mineral density and erosion.


  • Adhesive Bonding to Dentin Improved by Polymerizable Cyclodextrin Derivatives

    by Rafael L. Bowen, Gary E. Schumacher, Anthony A. Giuseppetti, Charles M. Guttman, Clifton M. Carey

    The objective of this work was to determine bonding characteristics of a hydrophilic monomer formulation containing polymerizable cyclodextrin derivatives. The hypothesis was that a formulation containing hydrophilic cross-linking diluent comonomers and cyclodextrins with functional groups attached by hydrolytically stable ether linkages could form strong adhesive bonds to dentin. The previously synthesized polymerizable cyclodextrin derivatives were formulated with sorbitol dimethacrylate, methacrylic acid and phenylbis(2,4,6-trimethylbenzoyl) phosphine oxide photoinitiator. The same formulation without the polymerizable cyclodextrin derivatives isolated the effects of the polymerizable cyclodextrin derivatives. A commercial self-etching bonding system was tested as a comparative control. Ground mid-coronal dentin was etched with 37 % phosphoric acid (H3PO4) for 15 s and rinsed with distilled water for 10 s. Formulations were applied to the moist dentin and light-cured 10 s. A packable composite was then applied through irises and light-cured 60 s. Teeth were stored in water for 24 h before bonds were tested in a shearing orientation. One-way ANOVA was performed on the data. The average values of shear bond strengths were defined as loads at fracture divided by the 4 mm diameter iris areas. The average value of shear bond strength for the formulation containing the polymerizable cyclodextrin derivatives was higher (p < 0.05), where p is a fraction of the probability distribution) than that of the same monomeric formulation except that the polymerizable cyclodextrin derivatives were not included. This was supporting evidence that the polymerizable cyclodextrin derivatives contributed to improved bonding. The average value of shear bond strength for the formulation containing the polymerizable cyclodextrin derivatives was also higher (p < 0.05) than that of the commercial self-etching bonding system. These preliminary results are in accordance with the hypothesis that formulations containing polymerizable cyclodextrin derivatives can form strong adhesive bonds to hydrated dentin surfaces. Further improvements in bonding to hydrated biological tissues by use of advanced formulations are anticipated.


  • Synthesis of Polymerizable Cyclodextrin Derivatives for Use in Adhesion-Promoting Monomer Formulations

    by Rafael L. Bowen, Clifton M. Carey, Kathleen M. Flynn, Charles M. Guttman

    The synthesis of the cyclodextrin derivatives reported herein was assisted by extensive literature research together with structure-property relationships derived from three-dimensional molecular modeling. These studies led to the hypothesis that many of the 21 hydroxyl groups on beta-cyclodextrin molecules could be derivatized to form a closely related family of analogous chemical compounds containing both polymerizable groups and hydrophilic ionizable ligand (substrate-binding) groups, each attached via hydrolytically-stable ether-linkages. The vinylbenzylether polymerizable groups should readily homopolymerize and also copolymerize with methacrylates. This could be highly useful for dental applications because substantially all contemporary dental resins and composites are based on methacrylate monomers. Due to hydrophilic ligands and residual hydroxyl groups, these cyclodextrin derivatives should penetrate hydrated layers of dentin and enamel to interact with collagen and tooth mineral. Analyses indicated that the diverse reaction products resulting from the method of synthesis reported herein should comprise a family of copolymerizable molecules that collectively contain about 30 different combinations of vinylbenzyl and hexanoate groups on the various molecules, with up to approximately seven of such groups combined on some of the molecules. Although the hypothesis was supported, and adhesive bonding to dentin is expected to be significantly improved by the use of these polymerizable cyclodextrin derivatives, other efforts are planned for improved synthetic methods to ensure that each of the reaction-product molecules will contain at least one copolymerizable moiety. The long-term objective is to enable stronger and more durable attachments of densely cross-linked polymers to hydrated hydrophilic substrates. Capabilities for bonding of hydrolytically stable polymers to dental and perhaps other hydrous biological tissues could provide widespread benefits.


  • Measurement of calcium activity in oral fluids by ion selective electrode: Method evaluation and simplified calculation of ion activity products

    by C.M. Carey, G.L. Vogel

    The activity of calcium in plaque fluid is needed to calculate the saturation level of that fluid relative to the tooth mineral. One method to determine the calcium activity in very small plaque fluid samples is by micro ion-selective electrode (ISE). Two commercially available calcium ionophores, a neutral-carrier and a charged-carrier, were evaluated in micro ISEs and compared to a commercially available macro ISE using saliva as a model for plaque fluid. The neutral-carrier containing ISEs gave results consistent with those of the macro ISE. Calcium activity measurements made with micro ISEs that contained the neutral ion-carrier of whole plaque samples and plaque fluid samples obtained by centrifugation of whole plaque showed that the activities did not change due to centrifugation. Estimates of the saturation with respect to hydroxyapatite were made from these measurements. A simplified calculation method is presented to estimate the ion activity product (IAP) of the calcium-phosphate minerals. The method is based on the relative abundance of some of the possible calcium-binding species and a fixed ionic strength for plaque fluid. Calculations show that within a normal pH range for plaque fluid (5.0 to 7.5) the differences in the IAP calculations for hydroxyapatite using the simplified method are less than those estimated from propagation of uncertainty calculations.