Joop C Duppen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Joop C Duppen has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Avraham Eisbruch
Department of Radiation Oncology, University of Michigan Ann Arbor, Michigan, USA
1 shared publication - Coen Rn Rasch
Department of Radiotherapy, The Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam, The Netherlands
1 shared publication - Frank A Pameijer
Current address: Department of Radiology, Universtiy Medical Center Utrecht, Utrecht, The Netherlands
1 shared publication - Frank Paulsen
Department of Radiation Oncology, University of Tübingen, Tübingen, Germany
1 shared publication - Isabelle Fitton
Department of Radiology, Georges Pompidou European Hospital, Paris Cité University, APHP, 75015 Paris, France
1 shared publication - Johannes Ham Kaanders
Department of Radiation Oncology, Radboud University Medical Center, Nijmegen, The Netherlands
1 shared publication
Latest Publications
- Open Access
- 15 March 2010
- Published by Springer Nature in Radiation Oncology
- Vol. 5 (1) , 21
Decreased 3D observer variation with matched CT-MRI, for target delineation in Nasopharynx cancer
To determine the variation in target delineation of nasopharyngeal carcinoma and the impact of measures to minimize this variation. For ten nasopharyngeal cancer patients, ten observers each delineated the Clinical Target Volume (CTV) and the CTV elective. After 3D analysis of the delineated volumes, a second delineation was performed. This implied improved delineation instructions, a combined delineation on CT and co-registered MRI, forced use of sagittal reconstructions, and an on-line anatomical atlas. Both for the CTV and the CTV elective delineations, the 3D SD decreased from Phase 1 to Phase 2, from 4.4 to 3.3 mm for the CTV and from 5.9 to 4.9 mm for the elective. There was an increase agreement, where the observers intended to delineate the same structure, from 36 to 64 surface % (p = 0.003) for the CTV and from 17 to 59% (p = 0.004) for the elective. The largest variations were at the caudal border of the delineations but these were smaller when an observer utilized the sagittal window. Hence, the use of sagittal side windows was enforced in the second phase and resulted in a decreased standard deviation for this area from 7.7 to 3.3 mm (p = 0.001) for the CTV and 7.9 to 5.6 mm (p = 0.03) for the CTV elective. Attempts to decrease the variation need to be tailored to the specific causes of the variation. Use of delineation instructions multimodality imaging, the use of sagittal windows and an on-line atlas result in a higher agreement on the intended target.
- 15 March 2010
- Published by Springer Nature in Radiation Oncology
- Vol. 5 (1) , 21
Open AccessDecreased 3D observer variation with matched CT-MRI, for target delineation in Nasopharynx cancer
To determine the variation in target delineation of nasopharyngeal carcinoma and the impact of measures to minimize this variation. For ten nasopharyngeal cancer patients, ten observers each delineated the Clinical Target Volume (CTV) and the CTV elective. After 3D analysis of the delineated volumes, a second delineation was performed. This implied improved delineation instructions, a combined delineation on CT and co-registered MRI, forced use of sagittal reconstructions, and an on-line anatomical atlas. Both for the CTV and the CTV elective delineations, the 3D SD decreased from Phase 1 to Phase 2, from 4.4 to 3.3 mm for the CTV and from 5.9 to 4.9 mm for the elective. There was an increase agreement, where the observers intended to delineate the same structure, from 36 to 64 surface % (p = 0.003) for the CTV and from 17 to 59% (p = 0.004) for the elective. The largest variations were at the caudal border of the delineations but these were smaller when an observer utilized the sagittal window. Hence, the use of sagittal side windows was enforced in the second phase and resulted in a decreased standard deviation for this area from 7.7 to 3.3 mm (p = 0.001) for the CTV and 7.9 to 5.6 mm (p = 0.03) for the CTV elective. Attempts to decrease the variation need to be tailored to the specific causes of the variation. Use of delineation instructions multimodality imaging, the use of sagittal windows and an on-line atlas result in a higher agreement on the intended target.