Michael B. Lawrence
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Michael B. Lawrence has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
Alexander L. Klibanov
Department of Biomedical Engineering, University of Virginia, Charlottesville, VA, USA
4 shared publicationsChristopher D. Paschall
Department of Biomedical Engineering, University of Virginia, Charlottesville, VA, USA
2 shared publicationsFrancesco Viola
HemoSonics, LLC, Charlottesville, Virginia, United States of America
2 shared publicationsJoshua J. Rychak
Targeson, Inc., San Diego, CA, United States
2 shared publications- Alexander L. Klibanov
Department of Medicine, Division of Cadiovascular Medicine, School of Medicine, University of Virginia, Charlottesville, VA 22903, USA
1 shared publication - Anthony S. Ham
Department of Biomedical Engineering, University of Virginia, Charlottesville, Virginia 22908, USA
1 shared publication
Latest Publications
- 10 February 2016
- Published by SAGE Publications in Biorheology
- Vol. 52 (5-6) , 415-432
Regulation of L-selectin-dependent hydrodynamic shear thresholding by leukocyte deformability and shear dependent bond number
Background: During inflammation leukocyte attachment to the blood vessel wall is augmented by capture of near-wall flowing leukocytes by previously adherent leukocytes. Adhesive interactions between flowing and adherent leukocytes are mediated by L-s
- 10 February 2016
- Published by SAGE Publications in Biorheology
- Vol. 52 (5-6) , 415-432
Regulation of L-selectin-dependent hydrodynamic shear thresholding by leukocyte deformability and shear dependent bond number
Background: During inflammation leukocyte attachment to the blood vessel wall is augmented by capture of near-wall flowing leukocytes by previously adherent leukocytes. Adhesive interactions between flowing and adherent leukocytes are mediated by L-s
- Open Access
- 4 June 2015
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (6) , e0128799
Integration of Acoustic Radiation Force and Optical Imaging for Blood Plasma Clot Stiffness Measurement
Despite the life-preserving function blood clotting serves in the body, inadequate or excessive blood clot stiffness has been associated with life-threatening diseases such as stroke, hemorrhage, and heart attack. The relationship between blood clot stiffness and vascular diseases underscores the importance of quantifying the magnitude and kinetics of blood’s transformation from a fluid to a viscoelastic solid. To measure blood plasma clot stiffness, we have developed a method that uses ultrasound acoustic radiation force (ARF) to induce micron-scaled displacements (1-500 μm) on microbeads suspended in blood plasma. The displacements were detected by optical microscopy and took place within a micro-liter sized clot region formed within a larger volume (2 mL sample) to minimize container surface effects. Modulation of the ultrasound generated acoustic radiation force allowed stiffness measurements to be made in blood plasma from before its gel point to the stage where it was a fully developed viscoelastic solid. A 0.5 wt % agarose hydrogel was 9.8-fold stiffer than the plasma (platelet-rich) clot at 1 h post-kaolin stimulus. The acoustic radiation force microbead method was sensitive to the presence of platelets and strength of coagulation stimulus. Platelet depletion reduced clot stiffness 6.9 fold relative to platelet rich plasma. The sensitivity of acoustic radiation force based stiffness assessment may allow for studying platelet regulation of both incipient and mature clot mechanical properties.
- 4 June 2015
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (6) , e0128799
Open AccessIntegration of Acoustic Radiation Force and Optical Imaging for Blood Plasma Clot Stiffness Measurement
Despite the life-preserving function blood clotting serves in the body, inadequate or excessive blood clot stiffness has been associated with life-threatening diseases such as stroke, hemorrhage, and heart attack. The relationship between blood clot stiffness and vascular diseases underscores the importance of quantifying the magnitude and kinetics of blood’s transformation from a fluid to a viscoelastic solid. To measure blood plasma clot stiffness, we have developed a method that uses ultrasound acoustic radiation force (ARF) to induce micron-scaled displacements (1-500 μm) on microbeads suspended in blood plasma. The displacements were detected by optical microscopy and took place within a micro-liter sized clot region formed within a larger volume (2 mL sample) to minimize container surface effects. Modulation of the ultrasound generated acoustic radiation force allowed stiffness measurements to be made in blood plasma from before its gel point to the stage where it was a fully developed viscoelastic solid. A 0.5 wt % agarose hydrogel was 9.8-fold stiffer than the plasma (platelet-rich) clot at 1 h post-kaolin stimulus. The acoustic radiation force microbead method was sensitive to the presence of platelets and strength of coagulation stimulus. Platelet depletion reduced clot stiffness 6.9 fold relative to platelet rich plasma. The sensitivity of acoustic radiation force based stiffness assessment may allow for studying platelet regulation of both incipient and mature clot mechanical properties.
- 1 February 2013
- Published by Elsevier in Journal of Controlled Release
- Vol. 165 (3) , 216-225
Ultrasound-based molecular imaging and specific gene delivery to mesenteric vasculature by endothelial adhesion molecule targeted microbubbles in a mouse model of Crohn's disease
- 1 February 2013
- Published by Elsevier in Journal of Controlled Release
- Vol. 165 (3) , 216-225
Ultrasound-based molecular imaging and specific gene delivery to mesenteric vasculature by endothelial adhesion molecule targeted microbubbles in a mouse model of Crohn's disease
- 1 November 2010
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 36 (11) , 1907-1918
Analysis of in vitro Transfection by Sonoporation Using Cationic and Neutral Microbubbles
- 1 November 2010
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 36 (11) , 1907-1918
Analysis of in vitro Transfection by Sonoporation Using Cationic and Neutral Microbubbles
- 1 May 2010
- Published by Elsevier in Clinica Chimica Acta
- Vol. 411 (9-10) , 638-644
Adaptive force sonorheometry for assessment of whole blood coagulation
- 1 May 2010
- Published by Elsevier in Clinica Chimica Acta
- Vol. 411 (9-10) , 638-644
Adaptive force sonorheometry for assessment of whole blood coagulation
- 21 July 2009
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 25 (17) , 10038-10044
Action at a Distance: Lengthening Adhesion Bonds with Poly(ethylene glycol) Spacers Enhances Mechanically Stressed Affinity for Improved Vascular Targeting of Microparticles
Poly(ethylene glycol) (PEG) chains were used to decorate microparticles with long adhesion ligands to emulate the efficacy of selectin-mediated leukocyte homing mechanisms. Ligands for P-selectin, an endothelial cell inflammatory marker, were coupled to PEG spacers of two sizes (MW 3400 and 10 000 Da) to investigate the effects on adhesion kinetics to P-selectin substrates. Under shear flow 80 nm PEG spacers improved P-selectin-antibody adhesion frequency by up to 4.5-fold and bond lifetimes by 7-fold compared to microparticles bearing chemisorbed antibody. Presentation of the glycosulfopeptide P-selectin ligands (2-GSP-6) and its nonsulfated low affinity form (2-GP-6) by long PEG spacers led to improved lifetimes of stressed bonds formed with P-selectin in shear flow and the rolling fluxes. Thus, structural features far removed from the binding pocket of a receptor that increase molecular contour length may enhance affinity in mechanically stressed environments such as those existing within the confines of the blood vessel. Such features may be useful for improving the performance of vascular-targeted micro- and nanoparticles used for drug, gene, and image contrast delivery. Ligand presentation on molecularly extended stalks may also serve to enhance any particle-surface interaction that takes place in laminar shear flow.
- 21 July 2009
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 25 (17) , 10038-10044
Action at a Distance: Lengthening Adhesion Bonds with Poly(ethylene glycol) Spacers Enhances Mechanically Stressed Affinity for Improved Vascular Targeting of Microparticles
Poly(ethylene glycol) (PEG) chains were used to decorate microparticles with long adhesion ligands to emulate the efficacy of selectin-mediated leukocyte homing mechanisms. Ligands for P-selectin, an endothelial cell inflammatory marker, were coupled to PEG spacers of two sizes (MW 3400 and 10 000 Da) to investigate the effects on adhesion kinetics to P-selectin substrates. Under shear flow 80 nm PEG spacers improved P-selectin-antibody adhesion frequency by up to 4.5-fold and bond lifetimes by 7-fold compared to microparticles bearing chemisorbed antibody. Presentation of the glycosulfopeptide P-selectin ligands (2-GSP-6) and its nonsulfated low affinity form (2-GP-6) by long PEG spacers led to improved lifetimes of stressed bonds formed with P-selectin in shear flow and the rolling fluxes. Thus, structural features far removed from the binding pocket of a receptor that increase molecular contour length may enhance affinity in mechanically stressed environments such as those existing within the confines of the blood vessel. Such features may be useful for improving the performance of vascular-targeted micro- and nanoparticles used for drug, gene, and image contrast delivery. Ligand presentation on molecularly extended stalks may also serve to enhance any particle-surface interaction that takes place in laminar shear flow.
- 26 February 2008
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 36 (4) , 622-631
L-Selectin Shear Thresholding Modulates Leukocyte Secondary Capture
Transient homotypic adhesions between flowing leukocytes and those previously adherent on the vessel wall has been proposed to amplify the accumulation of leukocytes at sites of inflammation. While adhesion of leukocytes to the vessel wall (primary capture) is mediated primarily by P-selectin on the endothelium and P-selectin Glycoprotein Ligand-1 (PSGL-1) on the leukocyte, the homotypic interactions leading to downstream leukocyte adhesion (secondary capture) are mediated primarily by reciprocal interactions between PSGL-1 and L-selectin on apposing leukocytes. One consequence of leukocyte secondary capture events are the formation of strings of adherent leukocytes as each recently captured leukocyte in turn captures another one flowing over its surface. Interestingly, PSGL-1-L-selectin interactions also mediate leukocyte hydrodynamic shear thresholding, whereby leukocyte rolling on purified L-selectin ligands such as PSGL-1 is maximized at a wall shear stress of ∼1 dyne/cm2 and minimized at both higher and lower flow rates. Using a novel quantitative method, we analyzed leukocyte string formation in vitro and found that hydrodynamic shear thresholding precluded secondary capture at low shear stresses yet amplified it at high shear stresses. Addition of the L-selectin mAb DREG-56 strongly inhibited leukocyte string formation, suggesting adhesion contributed significantly to hydrodynamic interactions in secondary capture processes. Taken together, the data suggest that secondary capture is modulated by the shear thresholding property of L-selectin. L-selectin mediated shear thresholding may therefore play a significant role in the regulation of leukocyte secondary capture in addition to recently described hydrodynamic recruitment mechanisms.
- 26 February 2008
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 36 (4) , 622-631
L-Selectin Shear Thresholding Modulates Leukocyte Secondary Capture
Transient homotypic adhesions between flowing leukocytes and those previously adherent on the vessel wall has been proposed to amplify the accumulation of leukocytes at sites of inflammation. While adhesion of leukocytes to the vessel wall (primary capture) is mediated primarily by P-selectin on the endothelium and P-selectin Glycoprotein Ligand-1 (PSGL-1) on the leukocyte, the homotypic interactions leading to downstream leukocyte adhesion (secondary capture) are mediated primarily by reciprocal interactions between PSGL-1 and L-selectin on apposing leukocytes. One consequence of leukocyte secondary capture events are the formation of strings of adherent leukocytes as each recently captured leukocyte in turn captures another one flowing over its surface. Interestingly, PSGL-1-L-selectin interactions also mediate leukocyte hydrodynamic shear thresholding, whereby leukocyte rolling on purified L-selectin ligands such as PSGL-1 is maximized at a wall shear stress of ∼1 dyne/cm2 and minimized at both higher and lower flow rates. Using a novel quantitative method, we analyzed leukocyte string formation in vitro and found that hydrodynamic shear thresholding precluded secondary capture at low shear stresses yet amplified it at high shear stresses. Addition of the L-selectin mAb DREG-56 strongly inhibited leukocyte string formation, suggesting adhesion contributed significantly to hydrodynamic interactions in secondary capture processes. Taken together, the data suggest that secondary capture is modulated by the shear thresholding property of L-selectin. L-selectin mediated shear thresholding may therefore play a significant role in the regulation of leukocyte secondary capture in addition to recently described hydrodynamic recruitment mechanisms.
- 1 November 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Asilomar Conference on Signals, Systems & Computers
- No. 10586393,p. 1856-1860
High Resolution Optical Tracking to Identify Adhesive Events in Vitro
Glycoproteins serve as ligands on metastatic cancer cells to mediate labile adhesive interactions with the vascular endothelium. The sub-second transience of carbohydrate-protein bonding events poses challenges for quantification of adhesion by optical tracking. We report the development of a simple, shape- based algorithm with novelty in its application to high spatiotemporal resolution tracking. We report positional and morphological signals from the spatial, time, and frequency domains for rigid particles and distensible cells. Error was comparable with previous methods: the resolution-dependent positional precision was 7 nm upon minimization of mechanical noise under experimental conditions.
- 1 November 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Asilomar Conference on Signals, Systems & Computers
- No. 10586393,p. 1856-1860
High Resolution Optical Tracking to Identify Adhesive Events in Vitro
Glycoproteins serve as ligands on metastatic cancer cells to mediate labile adhesive interactions with the vascular endothelium. The sub-second transience of carbohydrate-protein bonding events poses challenges for quantification of adhesion by optical tracking. We report the development of a simple, shape- based algorithm with novelty in its application to high spatiotemporal resolution tracking. We report positional and morphological signals from the spatial, time, and frequency domains for rigid particles and distensible cells. Error was comparable with previous methods: the resolution-dependent positional precision was 7 nm upon minimization of mechanical noise under experimental conditions.
- 17 August 2006
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 96 (3) , 596-607
Microparticle adhesive dynamics and rolling mediated by selectin‐specific antibodies under flow
In vitro studies were performed to characterize the relative performance of candidate receptors to target microparticles to inflammatory markers on vascular endothelium. To model the interactions of drug‐bearing microparticles or imaging contrast agents with the vasculature, 6 micron polystyrene particles bearing antibodies, peptides, or carbohydrates were perfused over immobilized E‐ or P‐selectin in a flow chamber. Microparticles conjugated with HuEP5C7.g2 (HuEP), a monoclonal antibody (mAb) specific to E‐ and P‐selectin, supported leukocyte‐like rolling and transient adhesion at venular shear rates. In contrast, microparticles conjugated with a higher affinity mAb specific for P‐selectin (G1) were unable to form bonds at venular flow rates. When both HuEP and G1 were conjugated to the microparticle, HuEP supported binding to P‐selectin in flow which allowed G1 to form bonds leading to stable adhesion. While the microparticle attachment and rolling performance was not as stable as that mediated by the natural ligands P‐selectin Glycoprotein Ligand‐1 or sialyl Lewisx, HuEP performed significantly better than any previously characterized mAb in terms of mediating microparticle binding under flow conditions. HuEP may be a viable alternative to natural ligands to selectins for targeting particles to inflamed endothelium. Biotechnol. Bioeng. 2007;96: 596–607.
- 17 August 2006
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 96 (3) , 596-607
Microparticle adhesive dynamics and rolling mediated by selectin‐specific antibodies under flow
In vitro studies were performed to characterize the relative performance of candidate receptors to target microparticles to inflammatory markers on vascular endothelium. To model the interactions of drug‐bearing microparticles or imaging contrast agents with the vasculature, 6 micron polystyrene particles bearing antibodies, peptides, or carbohydrates were perfused over immobilized E‐ or P‐selectin in a flow chamber. Microparticles conjugated with HuEP5C7.g2 (HuEP), a monoclonal antibody (mAb) specific to E‐ and P‐selectin, supported leukocyte‐like rolling and transient adhesion at venular shear rates. In contrast, microparticles conjugated with a higher affinity mAb specific for P‐selectin (G1) were unable to form bonds at venular flow rates. When both HuEP and G1 were conjugated to the microparticle, HuEP supported binding to P‐selectin in flow which allowed G1 to form bonds leading to stable adhesion. While the microparticle attachment and rolling performance was not as stable as that mediated by the natural ligands P‐selectin Glycoprotein Ligand‐1 or sialyl Lewisx, HuEP performed significantly better than any previously characterized mAb in terms of mediating microparticle binding under flow conditions. HuEP may be a viable alternative to natural ligands to selectins for targeting particles to inflamed endothelium. Biotechnol. Bioeng. 2007;96: 596–607.