Chen-Ming Hsu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Chen-Ming Hsu has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Ming-Yao Su
Department of Gastroenterology and Hepatology, Chang Gung Memorial Hospital at Linkou, Chang Gung University College of Medicine, Taoyuan, Taiwan,
3 shared publicationsCheng-Tang Chiu
Department of Gastroenterology and Hepatology, Chang Gung Memorial Hospital at Linkou, Chang Gung University College of Medicine, Taoyuan, Taiwan,
2 shared publicationsChang-Mu Sung
Department of Gastroenterology and Hepatology; Chang Gung Memorial Hospital; Taoyuan Taiwan
1 shared publication- Chau-Ting Yeh
Liver Research Center, Chang Gung Memorial Hospital, Taoyuan 333, Taiwan
1 shared publication - Cheng-Hsun Chiu
Molecular Infectious Disease Research Center, Chang Gung Memorial Hospital, Linkou, Taiwan
1 shared publication Chi-Huan Wu
Department of Gastroenterology and Hepatology; Chang Gung Memorial Hospital; Taoyuan Taiwan
1 shared publication
Latest Publications
- Open Access
- 1 July 2018
- Published by Taylor & Francis in Therapeutics and Clinical Risk Management
- Vol. ume 14, 1331-1336
Assessment of the Berlin Questionnaire for evaluation of hypoxemia risk in subjects undergoing deep sedation for screening gastrointestinal endoscopy
Background: Subjects with obstructive sleep apnea (OSA) are vulnerable to sedation-related complications during endoscopic procedures. A significant portion of subjects undergoing routine endoscopy is at high risk of OSA, but most are undiagnosed. The purpose of this study was to estimate the prevalence of high risk for OSA among Chinese subjects undergoing deep sedation for screening gastrointestinal endoscopy and to evaluate the hypoxemia risk of these examinees stratified by Berlin Questionnaire (BQ). Patients and methods: We performed a prospective cohort study in subjects undergoing deep sedation with monitored anesthesia care for combined esophagogastroduodenoscopy plus colonoscopy. Subjects who were Chinese were stratified into high- and low-risk groups for OSA by administration of BQ. Deep sedation was achieved via a propofol target-controlled infusion system. Hypoxemia was defined as pulse oximetry reading of less than 90%. The frequency of hypoxemia was compared between high- and low-risk groups for OSA. Results: A total of 615 Chinese subjects were recruited during the study period, and 614 subjects were included for analysis. Two hundred eighteen (35.5%) subjected were classified to be at high risk of OSA, and 396 (64.5%) were stratified to be at low risk of OSA by BQ. Hypoxemia occurred in 83 (13.5%) subjects during endoscopy procedures. The risk of developing hypoxemia in the high-risk group was significantly higher when compared to that of the low-risk group subjects (24.8% vs 7.3%; relative risk, 3.37; 95% CI, 2.22–5.13). Conclusion: About one-third Chinese subjects undergoing deep sedation for screening endoscopy were at high risk of OSA. Subjects at high risk of OSA are associated with an increased risk of hypoxemia in comparison to the low-risk group when undergoing deep sedation for screening gastrointestinal endoscopy.
- 1 July 2018
- Published by Taylor & Francis in Therapeutics and Clinical Risk Management
- Vol. ume 14, 1331-1336
Open AccessAssessment of the Berlin Questionnaire for evaluation of hypoxemia risk in subjects undergoing deep sedation for screening gastrointestinal endoscopy
Background: Subjects with obstructive sleep apnea (OSA) are vulnerable to sedation-related complications during endoscopic procedures. A significant portion of subjects undergoing routine endoscopy is at high risk of OSA, but most are undiagnosed. The purpose of this study was to estimate the prevalence of high risk for OSA among Chinese subjects undergoing deep sedation for screening gastrointestinal endoscopy and to evaluate the hypoxemia risk of these examinees stratified by Berlin Questionnaire (BQ). Patients and methods: We performed a prospective cohort study in subjects undergoing deep sedation with monitored anesthesia care for combined esophagogastroduodenoscopy plus colonoscopy. Subjects who were Chinese were stratified into high- and low-risk groups for OSA by administration of BQ. Deep sedation was achieved via a propofol target-controlled infusion system. Hypoxemia was defined as pulse oximetry reading of less than 90%. The frequency of hypoxemia was compared between high- and low-risk groups for OSA. Results: A total of 615 Chinese subjects were recruited during the study period, and 614 subjects were included for analysis. Two hundred eighteen (35.5%) subjected were classified to be at high risk of OSA, and 396 (64.5%) were stratified to be at low risk of OSA by BQ. Hypoxemia occurred in 83 (13.5%) subjects during endoscopy procedures. The risk of developing hypoxemia in the high-risk group was significantly higher when compared to that of the low-risk group subjects (24.8% vs 7.3%; relative risk, 3.37; 95% CI, 2.22–5.13). Conclusion: About one-third Chinese subjects undergoing deep sedation for screening endoscopy were at high risk of OSA. Subjects at high risk of OSA are associated with an increased risk of hypoxemia in comparison to the low-risk group when undergoing deep sedation for screening gastrointestinal endoscopy.
- Open Access
- 7 September 2017
- Published by Wiley in Advances in Digestive Medicine
- Vol. 4 (3) , 94-98
Recurrent bleeding of colonic diverticular hemorrhage after endoscopic treatment: Clinical experience of an endoscopic center
- 7 September 2017
- Published by Wiley in Advances in Digestive Medicine
- Vol. 4 (3) , 94-98
Open AccessRecurrent bleeding of colonic diverticular hemorrhage after endoscopic treatment: Clinical experience of an endoscopic center
- Open Access
- 19 July 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (7) , e69111
A Comparison of Positron Emission Tomography and Colonoscopy for the Detection of Advanced Colorectal Neoplasms in Subjects Undergoing a Health Check-Up
There is no agreement as to whether F-18 fluorodeoxyglucose positron emission tomography and computed tomography (FDG PET/CT) screening for advanced colorectal neoplasms is meaningful. This retrospective study was undertaken to determine whether FDG PET/CT may be a valuable screening tool for the detection of advanced colorectal neoplasms. A retrospective review of the records of 1,109 FDG PET/CT scans acquired from January 2007 to December 2011 was performed. Colonoscopy and FDG PET/CT imaging were performed within two days of each other. The results of colonoscopy were taken as the gold standard, either with or without the results of the histopathological examination. An advanced neoplasm was defined as the presence of a malignant tumor, an adenoma ≥1 cm, or histological evidence of high-grade dysplasia or significant villous components. A total of 36 subjects had advanced colorectal neoplasms detected by colonoscopy (totaling 38 neoplasms). Six of the 38 neoplasms were also detected by FDG PET/CT. The sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy of FDG PET/CT in the detection of advanced colorectal neoplasms were 15.8% (6/38), 99.1% (1063/1073), 37.5% (6/16), 97.1% (1063/1095), and 96.2% (1069/1111) respectively. The presence of lesions with an endoscopic size ≤1.5 cm (P<0.001) and low-grade dysplasia (P<0.001) were the main predictors of false-negative FDG PET/CT findings. We conclude that FDG PET/CT screening of advanced colorectal neoplasms is unwarranted, especially in the presence of lesions with an endoscopic size ≤1.5 cm or low-grade dysplasia.
- 19 July 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (7) , e69111
Open AccessA Comparison of Positron Emission Tomography and Colonoscopy for the Detection of Advanced Colorectal Neoplasms in Subjects Undergoing a Health Check-Up
There is no agreement as to whether F-18 fluorodeoxyglucose positron emission tomography and computed tomography (FDG PET/CT) screening for advanced colorectal neoplasms is meaningful. This retrospective study was undertaken to determine whether FDG PET/CT may be a valuable screening tool for the detection of advanced colorectal neoplasms. A retrospective review of the records of 1,109 FDG PET/CT scans acquired from January 2007 to December 2011 was performed. Colonoscopy and FDG PET/CT imaging were performed within two days of each other. The results of colonoscopy were taken as the gold standard, either with or without the results of the histopathological examination. An advanced neoplasm was defined as the presence of a malignant tumor, an adenoma ≥1 cm, or histological evidence of high-grade dysplasia or significant villous components. A total of 36 subjects had advanced colorectal neoplasms detected by colonoscopy (totaling 38 neoplasms). Six of the 38 neoplasms were also detected by FDG PET/CT. The sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy of FDG PET/CT in the detection of advanced colorectal neoplasms were 15.8% (6/38), 99.1% (1063/1073), 37.5% (6/16), 97.1% (1063/1095), and 96.2% (1069/1111) respectively. The presence of lesions with an endoscopic size ≤1.5 cm (P<0.001) and low-grade dysplasia (P<0.001) were the main predictors of false-negative FDG PET/CT findings. We conclude that FDG PET/CT screening of advanced colorectal neoplasms is unwarranted, especially in the presence of lesions with an endoscopic size ≤1.5 cm or low-grade dysplasia.
- Open Access
- 8 August 2009
- Published by Springer Nature in BMC Medical Genomics
- Vol. 2 (1) , 51
Hepatic inflammation mediated by hepatitis C virus core protein is ameliorated by blocking complement activation
The pathogenesis of inflammation and fibrosis in chronic hepatitis C virus (HCV) infection remains unclear. Transgenic mice with constitutive HCV core over-expression display steatosis only. While the reasons for this are unclear, it may be important that core protein production in these models begins during gestation, in contrast to human hepatitis C virus infection, which occurs post-natally and typically in adults. AIMS: To more realistically model the effect of core protein production in the adult liver, we developed a mouse with conditional expression of HCV core and examined the effect of core protein production in the adult liver.
- 8 August 2009
- Published by Springer Nature in BMC Medical Genomics
- Vol. 2 (1) , 51
Open AccessHepatic inflammation mediated by hepatitis C virus core protein is ameliorated by blocking complement activation
The pathogenesis of inflammation and fibrosis in chronic hepatitis C virus (HCV) infection remains unclear. Transgenic mice with constitutive HCV core over-expression display steatosis only. While the reasons for this are unclear, it may be important that core protein production in these models begins during gestation, in contrast to human hepatitis C virus infection, which occurs post-natally and typically in adults. AIMS: To more realistically model the effect of core protein production in the adult liver, we developed a mouse with conditional expression of HCV core and examined the effect of core protein production in the adult liver.