Frank Ahlhelm
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Frank Ahlhelm has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
W. Reith
Universitätsklinkum des Saarlandes
11 shared publicationsA. Nabhan
Universitätsklinikum des Saarlandes
6 shared publicationsJ. Kelm
Universitätsklinikum des Saarlandes, Homburg/Saar
5 shared publicationsN. Naumann
Universitätsklinikum des Saarlandes
5 shared publicationsG. Schulte-Altedorneburg
Universitätsklinikum des Saarlandes
4 shared publicationsI. Grunwald
Universitätsklinikum des Saarlandes
4 shared publications
Latest Publications
- 26 June 2010
- Published by Springer Nature in Der Radiologe
- Vol. 50 (8) , 651-652
Quo vadis ACI-Stent?
- 12 August 2009
- Published by Springer Nature in Der Radiologe
- Vol. 50 (2) , 165-180
Spinale Tumoren
Zusammenfassung Spinale Tumoren können intramedullär, innerhalb der Meningen (intradural), zwischen Meningen und Knochen (extradural) auftreten oder von anderen Lokalisationen sekundär zu einer Beteiligung der Wirbelsäule führen. Das Wirbelkörperhämangiom ist der häufigste gutartige Tumor der Wirbelsäule. Zu den häufigsten malignen spinalen Tumoren gehören Metastasen, das Lymphom und das multiple Myelom. Primäre Knochentumoren der Wirbelsäule sind im Vergleich dazu eher selten und zeigen auch oft charakteristische Bildbefunde. Für die Differenzialdiagnostik spielen das Patientenalter, die Lokalisation des Tumors und die magnetresonanz- und computertomographischen Befunde eine wichtige Rolle.
- 12 August 2009
- Published by Springer Nature in Der Radiologe
- Vol. 50 (2) , 165-180
Spinale Tumoren
Zusammenfassung Spinale Tumoren können intramedullär, innerhalb der Meningen (intradural), zwischen Meningen und Knochen (extradural) auftreten oder von anderen Lokalisationen sekundär zu einer Beteiligung der Wirbelsäule führen. Das Wirbelkörperhämangiom ist der häufigste gutartige Tumor der Wirbelsäule. Zu den häufigsten malignen spinalen Tumoren gehören Metastasen, das Lymphom und das multiple Myelom. Primäre Knochentumoren der Wirbelsäule sind im Vergleich dazu eher selten und zeigen auch oft charakteristische Bildbefunde. Für die Differenzialdiagnostik spielen das Patientenalter, die Lokalisation des Tumors und die magnetresonanz- und computertomographischen Befunde eine wichtige Rolle.
- Open Access
- 16 June 2009
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 32 (5) , 1019-1027
Carotid Artery Stenting Using a Novel Self-Expanding Braided Nickel–Titanium Stent: Feasibility and Safety Porcine Trial
We studied the deliverability and safety of a braided, self-expanding, closed-cell nickel–titanium (NiTi) stent (E-volution, Jotec GmbH, Hechingen, Germany) especially designed for the endovascular treatment of carotid artery bifurcation stenosis with special regard to in-stent stenosis and thrombosis compared with a laser-cut reference nitinol stent in a porcine model of percutaneous vascular interventions. We aimed to assess histopathologic response in minipig carotid and subclavian arteries. Eight minipigs received a total of 42 stents: 14 reference stents and 28 E-volution stents. Eleven of the E-volution stents were additionally coated with heparin. Control angiography was obtained immediately before and after vascular intervention as well as 4 weeks after the procedure. Primary endpoints were 28 days of angiographic analyses as well as histomorphometric analysis, including injury score, inflammation score, luminal diameter, vessel diameter, maximal neointimal thickness, and area of in-stent stenosis. Secondary end points were procedural success, 28-day mortality, and stent thrombosis. All stents could be delivered successfully without procedural complications, morbidity, or mortality during our observation time. As confirmed by histology, no in-stent thrombosis was observed. Compared with common carotid arteries, subclavian arteries are significantly more vulnerable to developing in-stent stenosis caused by neointima proliferation (p < 0.05). Compared with the use of 1 single stent/artery, serial application of two stents leads to a more excessive but not significantly different neointimal proliferation (p > 0.05). The E-volution stent, especially when heparin coated, is in line with the comparison to the laser-cut reference stent displaying similar results of angiographic, histologic, and histomorphometric analyses (p > 0.05). Compared with the reference laser-cut stent, the self-expanding nitinol stent (E-volution) with its advanced braiding technology is feasible and safe. In our opinion, the high radial resistive force and the advanced braided design with tight stent-strut interstices may be beneficial in terms of plaque stabilization. Further studies are necessary and warranted.
- 16 June 2009
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 32 (5) , 1019-1027
Open AccessCarotid Artery Stenting Using a Novel Self-Expanding Braided Nickel–Titanium Stent: Feasibility and Safety Porcine Trial
We studied the deliverability and safety of a braided, self-expanding, closed-cell nickel–titanium (NiTi) stent (E-volution, Jotec GmbH, Hechingen, Germany) especially designed for the endovascular treatment of carotid artery bifurcation stenosis with special regard to in-stent stenosis and thrombosis compared with a laser-cut reference nitinol stent in a porcine model of percutaneous vascular interventions. We aimed to assess histopathologic response in minipig carotid and subclavian arteries. Eight minipigs received a total of 42 stents: 14 reference stents and 28 E-volution stents. Eleven of the E-volution stents were additionally coated with heparin. Control angiography was obtained immediately before and after vascular intervention as well as 4 weeks after the procedure. Primary endpoints were 28 days of angiographic analyses as well as histomorphometric analysis, including injury score, inflammation score, luminal diameter, vessel diameter, maximal neointimal thickness, and area of in-stent stenosis. Secondary end points were procedural success, 28-day mortality, and stent thrombosis. All stents could be delivered successfully without procedural complications, morbidity, or mortality during our observation time. As confirmed by histology, no in-stent thrombosis was observed. Compared with common carotid arteries, subclavian arteries are significantly more vulnerable to developing in-stent stenosis caused by neointima proliferation (p < 0.05). Compared with the use of 1 single stent/artery, serial application of two stents leads to a more excessive but not significantly different neointimal proliferation (p > 0.05). The E-volution stent, especially when heparin coated, is in line with the comparison to the laser-cut reference stent displaying similar results of angiographic, histologic, and histomorphometric analyses (p > 0.05). Compared with the reference laser-cut stent, the self-expanding nitinol stent (E-volution) with its advanced braiding technology is feasible and safe. In our opinion, the high radial resistive force and the advanced braided design with tight stent-strut interstices may be beneficial in terms of plaque stabilization. Further studies are necessary and warranted.
- 20 March 2009
- Published by Springer Nature in Der Radiologe
- Vol. 49 (4) , 305-311
Magnetresonanz- und computertomographische Befunde bei lakunären Hirninfarkten
- 20 March 2009
- Published by Springer Nature in Der Radiologe
- Vol. 49 (4) , 305-311
Magnetresonanz- und computertomographische Befunde bei lakunären Hirninfarkten
- 1 December 2008
- Published by Springer Nature in Der Radiologe
- Vol. 48 (12) , 1109
Endovaskuläre Behandlung symptomatischer intrakranieller Gefäßstenosen: es bleibt spannend!
- 1 December 2008
- Published by Springer Nature in Der Radiologe
- Vol. 48 (12) , 1109
Endovaskuläre Behandlung symptomatischer intrakranieller Gefäßstenosen: es bleibt spannend!
- 31 August 2007
- Published by Springer Nature in Der Radiologe
- Vol. 47 (10) , 863-867
Kavernöse Malformationen
Cavernomas of the CNS may involve brain parenchyma as well as the spinal cord and belong to those cerebrovascular malformations that have no arteriovenous shunt and thus are generally angiographically occult. Contrary to computed tomography (CT), which is generally suited to reveal calcifications or acute bleeding, magnetic resonance imaging (MRI) enables detection of even small cavernomas. A frequently associated venous anomaly is helpful for correct diagnosis.
- 31 August 2007
- Published by Springer Nature in Der Radiologe
- Vol. 47 (10) , 863-867
Kavernöse Malformationen
Cavernomas of the CNS may involve brain parenchyma as well as the spinal cord and belong to those cerebrovascular malformations that have no arteriovenous shunt and thus are generally angiographically occult. Contrary to computed tomography (CT), which is generally suited to reveal calcifications or acute bleeding, magnetic resonance imaging (MRI) enables detection of even small cavernomas. A frequently associated venous anomaly is helpful for correct diagnosis.
- 17 August 2007
- Published by Springer Nature in Neuroradiology
- Vol. 49 (12) , 1023-1028
Treatment of wide-necked intracranial aneurysms with a novel self-expanding two-zonal endovascular stent device
Endovascular treatment of intracerebral wide-necked aneurysms carries the risk of incomplete embolisation and recanalisation of the aneurysm as well as coil protrusion into the parent artery and embolic complications. We present preliminary results with the placement of a novel tightly braided stent across the aneurysm neck which might lead to thrombosis of these aneurysms.
- 17 August 2007
- Published by Springer Nature in Neuroradiology
- Vol. 49 (12) , 1023-1028
Treatment of wide-necked intracranial aneurysms with a novel self-expanding two-zonal endovascular stent device
Endovascular treatment of intracerebral wide-necked aneurysms carries the risk of incomplete embolisation and recanalisation of the aneurysm as well as coil protrusion into the parent artery and embolic complications. We present preliminary results with the placement of a novel tightly braided stent across the aneurysm neck which might lead to thrombosis of these aneurysms.
- 1 December 2006
- Published by Springer Nature in Der Radiologe
- Vol. 46 (12) , 1035-1043
Bildgebung extraduraler Raumforderungen
- 1 December 2006
- Published by Springer Nature in Der Radiologe
- Vol. 46 (12) , 1035-1043
Bildgebung extraduraler Raumforderungen
- 1 October 2006
- Published by Springer Nature in Der Radiologe
- Vol. 46 (10) , 905-918
Hirninfarkt