Larry Miller
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Larry Miller has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Annapurna Korimilli
Section of Gastroenterology, Department of Medicine, Temple University Hospital, Philadelphia, PA 19140, USA
3 shared publicationsAmit Kalra
Section of Gastroenterology, Department of Medicine, Temple University Hospital, Philadelphia, PA 19140, USA
2 shared publicationsAnil Vegesna
Section of Gastroenterology, Department of Medicine, Temple University Hospital, Philadelphia, PA 19140, USA
2 shared publications- Anil Vegesna
Department of Medicine, Section of Gastroenterology, Temple University Hospital, Philadelphia, PA 19140, USA
2 shared publications Qing Dai
Temple University Hospital
2 shared publicationsRamashesai Besetty
Section of Gastroenterology, Department of Medicine, Temple University Hospital, Philadelphia, PA 19140, USA
2 shared publications
Latest Publications
- 1 April 2011
- Published by Springer Nature in Digestive Diseases and Sciences
- Vol. 56 (10) , 3053-3057
Acoustic Liver Biopsy in Patients with Hepatitis C and Advanced Liver Fibrosis Using Endoscopic Ultrasound
Transabdominal ultrasound cannot be used to quantitate fibrosis in patients with advanced liver fibrosis due to variability in the abdominal wall thickness and composition. This variability can be eliminated by using endoscopic ultrasound. The purpose of this study was to determine the amount of fibrosis in the liver of hepatitis C patients with advanced fibrosis using endoscopic ultrasound. Endoscopic ultrasound images of the liver were recorded by keeping the gain, contrast, frequency, magnification and acoustic power constant on the ultrasound processor. Videotaped images of the liver were digitized on Image-Pro Plus software. Using adobe Photoshop, a histogram was produced to quantitate the luminosity of the five areas of interest per image. Quantification of the ultrasound images were done by two independent investigators blinded to the Ishak liver fibrosis score. The mean luminosity of the ultrasound images were compared with the Ishak fibrosis score. The study was performed in seven patients (mean age 54 years; 3 male, 4 female) with hepatitis C and advanced liver fibrosis. The correlation between the two independent investigators for the ultrasound images was 0.93. The correlation between the mean luminosity on ultrasound images to the Ishak fibrosis score was r = 0.77, r = 0.72 and r = 0.73 for the most hyperechoic area of interest, total hyperechoic area and for the entire liver, respectively. A new technique was developed that uses endoscopic ultrasound to evaluate the degree of fibrosis in patients with advanced liver fibrosis. There is a good correlation between the luminosity on endoscopic ultrasound and the Ishak fibrosis score.
- 1 April 2011
- Published by Springer Nature in Digestive Diseases and Sciences
- Vol. 56 (10) , 3053-3057
Acoustic Liver Biopsy in Patients with Hepatitis C and Advanced Liver Fibrosis Using Endoscopic Ultrasound
Transabdominal ultrasound cannot be used to quantitate fibrosis in patients with advanced liver fibrosis due to variability in the abdominal wall thickness and composition. This variability can be eliminated by using endoscopic ultrasound. The purpose of this study was to determine the amount of fibrosis in the liver of hepatitis C patients with advanced fibrosis using endoscopic ultrasound. Endoscopic ultrasound images of the liver were recorded by keeping the gain, contrast, frequency, magnification and acoustic power constant on the ultrasound processor. Videotaped images of the liver were digitized on Image-Pro Plus software. Using adobe Photoshop, a histogram was produced to quantitate the luminosity of the five areas of interest per image. Quantification of the ultrasound images were done by two independent investigators blinded to the Ishak liver fibrosis score. The mean luminosity of the ultrasound images were compared with the Ishak fibrosis score. The study was performed in seven patients (mean age 54 years; 3 male, 4 female) with hepatitis C and advanced liver fibrosis. The correlation between the two independent investigators for the ultrasound images was 0.93. The correlation between the mean luminosity on ultrasound images to the Ishak fibrosis score was r = 0.77, r = 0.72 and r = 0.73 for the most hyperechoic area of interest, total hyperechoic area and for the entire liver, respectively. A new technique was developed that uses endoscopic ultrasound to evaluate the degree of fibrosis in patients with advanced liver fibrosis. There is a good correlation between the luminosity on endoscopic ultrasound and the Ishak fibrosis score.
- Open Access
- 18 March 2010
- Published by Wiley in Gastroenterology Research and Practice
- Vol. 2010, 1-5
Induced Opening of the Gastroesophageal Junction Occurs at a Lower Gastric Pressure in Gerd Patients and in Hiatal Hernia Subjects than in Normal Control Subjects
Purpose. To determine intragastric pressure threshold for inducing gastroesophageal junction (GEJ) opening in normal control subjects with and without hiatal hernia, and in patients with gastroesophageal reflux disease.Methods. This study was performed in 13 normal volunteers, 5 volunteers with hiatal hernia, and 3 patients with gastroesophageal reflux disease. During endoscopy a pressure transducer was used to measure baseline gastric pressures. The pressure in the stomach was measured while air was insufflated into the stomach until the gastroesophageal junction opened on endoscopic view.Results. There were two patterns of GEJ opening in normal volunteers. The mean opening pressure for Gastroesophageal junction in normal pattern-I, normal pattern-II, hiatal hernia, and Gastroesophageal reflux patients was 11.5, 12.6, 3.4, and 1.3 mmHg, respectively.Conclusions. GEJ opening is induced at a significantly lower pressure in subjects with hiatal hernia and in patients with gastroesophageal reflux disease than in normal volunteers.
- 18 March 2010
- Published by Wiley in Gastroenterology Research and Practice
- Vol. 2010, 1-5
Open AccessInduced Opening of the Gastroesophageal Junction Occurs at a Lower Gastric Pressure in Gerd Patients and in Hiatal Hernia Subjects than in Normal Control Subjects
Purpose. To determine intragastric pressure threshold for inducing gastroesophageal junction (GEJ) opening in normal control subjects with and without hiatal hernia, and in patients with gastroesophageal reflux disease.Methods. This study was performed in 13 normal volunteers, 5 volunteers with hiatal hernia, and 3 patients with gastroesophageal reflux disease. During endoscopy a pressure transducer was used to measure baseline gastric pressures. The pressure in the stomach was measured while air was insufflated into the stomach until the gastroesophageal junction opened on endoscopic view.Results. There were two patterns of GEJ opening in normal volunteers. The mean opening pressure for Gastroesophageal junction in normal pattern-I, normal pattern-II, hiatal hernia, and Gastroesophageal reflux patients was 11.5, 12.6, 3.4, and 1.3 mmHg, respectively.Conclusions. GEJ opening is induced at a significantly lower pressure in subjects with hiatal hernia and in patients with gastroesophageal reflux disease than in normal volunteers.
- 9 July 2009
- Published by Wiley in Neurogastroenterology & Motility
- Vol. 21 (8) , 813-e52
A missing sphincteric component of the gastro-oesophageal junction in patients with GORD
- 9 July 2009
- Published by Wiley in Neurogastroenterology & Motility
- Vol. 21 (8) , 813-e52
A missing sphincteric component of the gastro-oesophageal junction in patients with GORD
- 13 February 2008
- Published by Springer Nature in Digestive Diseases and Sciences
- Vol. 53 (4) , 1078-1083
Acoustic Liver Biopsy Using Endoscopic Ultrasound
Background Transabdominal ultrasound cannot be used to quantitate fibrosis in patients with cirrhosis because of variability in the abdominal wall thickness and variability in the components of the abdominal wall (fat versus muscle). Endoscopic ultrasound through the gastric wall is always at a constant distance, approximately 3 mm, away from the liver when the transducer is just below the gastroesophageal junction, thereby eliminating this variability. Purpose To differentiate between cirrhotic and noncirrhotic liver using endoluminal ultrasound. Methods Eleven patients without known liver disease and eight patients with cirrhosis underwent endoscopic ultrasound using an Olympus linear ultrasound scope. The gain, contrast, frequency, and acoustic power were kept constant on the Aloka ultrasound processor. Videotaped images of the liver were recorded and then digitized on Image-Pro Plus software. The brightness of the image was adjusted to a standard brightness for each image and an area of interest was chosen using Photoshop 7.0. Vessels and artifacts were eliminated digitally and a histogram was produced using Photoshop to quantitate the pixel density for the area of interest from 0 (black) to 255 (white). Approximately 250,000 pixels were evaluated for each subject. The mean ± standard deviation (SD) pixel density of the noncirrhotic subjects was evaluated against the cirrhotic patients using a Student unpaired t-test. Results The mean echogenecity in patients with cirrhosis was 116.85 and the mean echogenecity in patients without cirrhosis was 92.75 (P < 0.002). The mean standard deviation of the pixel density in patients with cirrhosis was 19.08 and the mean standard deviation of the pixel density in patients without cirrhosis was 13.25 (P < 0.0004). Using these criteria the subjects with cirrhosis were segregated from the noncirrhotic subjects (normal subjects and the subjects with steatosis) with 100% sensitivity and 100% specificity. Conclusion A new method of evaluating the liver parenchyma (acoustic liver biopsy) that takes advantage of the proximity of the endoscopic ultrasound transducer to the liver and uses commercial image analysis technology that is inexpensive and widely available was developed. This is a preliminary study of this new technology, which demonstrates that endoscopic ultrasound, can be standardized in order to image, analyze, and compare the mean echogenecity and mean standard deviation of the pixel density in the liver in order to distinguish cirrhotic patients from patients without cirrhosis.
- 13 February 2008
- Published by Springer Nature in Digestive Diseases and Sciences
- Vol. 53 (4) , 1078-1083
Acoustic Liver Biopsy Using Endoscopic Ultrasound
Background Transabdominal ultrasound cannot be used to quantitate fibrosis in patients with cirrhosis because of variability in the abdominal wall thickness and variability in the components of the abdominal wall (fat versus muscle). Endoscopic ultrasound through the gastric wall is always at a constant distance, approximately 3 mm, away from the liver when the transducer is just below the gastroesophageal junction, thereby eliminating this variability. Purpose To differentiate between cirrhotic and noncirrhotic liver using endoluminal ultrasound. Methods Eleven patients without known liver disease and eight patients with cirrhosis underwent endoscopic ultrasound using an Olympus linear ultrasound scope. The gain, contrast, frequency, and acoustic power were kept constant on the Aloka ultrasound processor. Videotaped images of the liver were recorded and then digitized on Image-Pro Plus software. The brightness of the image was adjusted to a standard brightness for each image and an area of interest was chosen using Photoshop 7.0. Vessels and artifacts were eliminated digitally and a histogram was produced using Photoshop to quantitate the pixel density for the area of interest from 0 (black) to 255 (white). Approximately 250,000 pixels were evaluated for each subject. The mean ± standard deviation (SD) pixel density of the noncirrhotic subjects was evaluated against the cirrhotic patients using a Student unpaired t-test. Results The mean echogenecity in patients with cirrhosis was 116.85 and the mean echogenecity in patients without cirrhosis was 92.75 (P < 0.002). The mean standard deviation of the pixel density in patients with cirrhosis was 19.08 and the mean standard deviation of the pixel density in patients without cirrhosis was 13.25 (P < 0.0004). Using these criteria the subjects with cirrhosis were segregated from the noncirrhotic subjects (normal subjects and the subjects with steatosis) with 100% sensitivity and 100% specificity. Conclusion A new method of evaluating the liver parenchyma (acoustic liver biopsy) that takes advantage of the proximity of the endoscopic ultrasound transducer to the liver and uses commercial image analysis technology that is inexpensive and widely available was developed. This is a preliminary study of this new technology, which demonstrates that endoscopic ultrasound, can be standardized in order to image, analyze, and compare the mean echogenecity and mean standard deviation of the pixel density in the liver in order to distinguish cirrhotic patients from patients without cirrhosis.
- 30 September 2007
- Published by Elsevier in Gastroenterology Clinics of North America
- Vol. 36 (3) , 601-617
New Observations on the Gastroesophageal Antireflux Barrier
- 30 September 2007
- Published by Elsevier in Gastroenterology Clinics of North America
- Vol. 36 (3) , 601-617
New Observations on the Gastroesophageal Antireflux Barrier