Qian Ma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Qian Ma has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Yue-Heng Yang
State Key Laboratory of Lithospheric and Environmental Coevolution, Institute of Geology and Geophysics, Chinese Academy of Sciences, Beijing, 100029, P.R. China
2 shared publications Zhuyin Chu
State Key Laboratory of Lithospheric and Environmental Coevolution Institute of Geology and Geophysics, Chinese Academy of Sciences Beijing 100029 China
2 shared publicationsChao Huang
State Key Laboratory of Lithospheric Evolution, Institute of Geology and Geophysics, Chinese Academy of Sciences, Beijing, P. R. China
1 shared publicationChao Wei
Division of Chemical Metrology and Analytical Science, National Institute of Metrology, No. 18 Beisanhuan Donglu, Chaoyang Dist., Beijing 100029, China; Key Laboratory of Chemical Metrology and Applications on Nutrition and Health for State Market Regulation, No. 18 Beisanhuan Donglu, Chaoyang Dist., Beijing 100029, China
1 shared publicationHan Zhao
State Key Laboratory of Lithospheric Evolution, Institute of Geology and Geophysics, Chinese Academy of Sciences, Beijing, P. R. China
1 shared publicationHaoqi Ma
State Key Laboratory of Deep Earth and Mineral Exploration Institute of Geology, Chinese Academy of Geological Sciences Beijing 100037 China
1 shared publication
Latest Publications
- 23 June 2026
- Published by Wiley in Geostandards and Geoanalytical Research
Systematic Characterisation of Natural Titanite Reference Materials (Ontario, T3 and Pakistan) for High Spatial‐Resolution U‐Pb Microanalysis
Three previously introduced titanites, Ontario, T3 and Pakistan, were evaluated as potential reference materials (RMs) for high spatial‐resolution U‐Pb microanalysis, offering valuable additions to the currently limited suite of titanite RMs. Comprehensive characterisation through microanalytical techniques, including scanning electron microscope, electron probe micro‐analysis, secondary ion mass spectrometry (SIMS) and laser ablation‐inductively coupled plasma‐mass spectrometry (LA‐ICP‐MS), reveal that the Proterozoic‐age Ontario titanite is inclusion‐free and homogeneous within analytical uncertainty in terms of major and trace elements, U‐Pb isotopes and U‐Pb ages. The Miocene‐age Pakistan titanite, though relatively low in U and Pb contents, also shows homogeneity in U‐Pb isotopes and ages at the scale of analytical precision. Isotope dilution thermal ionisation mass spectrometry (ID‐TIMS) results are reported for the first time for both Ontario and Pakistan titanites. Accordingly, analyses of the Ontario titanite fragments range from concordant to variably discordant but yield a robust weighted mean 207 Pb/ 206 Pb date of 1048.5 ± 3.3 Ma (2 s “internal” uncertainty, n = 9). Cross‐calibration with other titanite RMs by LA‐ICP‐MS demonstrates that Ontario is suitable as a primary RM for determining U‐Pb ages of titanite ranging in age from Precambrian to Neogene. ID‐TIMS analyses of the Pakistan titanite yield overlapping data with a weighted mean 206 Pb/ 238 U date of 20.759 ± 0.055 Ma (2 s “internal” uncertainty, n = 10). Considering its relatively young age, Pakistan titanite is recommended as a secondary RM for quality control of young titanites dating by LA‐ICP‐MS and SIMS. In contrast, the T3 titanite exhibits significant intra‐ and inter‐grain heterogeneity. The brighter zone in BSE images (T3‐LG) has relatively high and homogeneous rare earth elements contents and yields a lower intercept age of 1099 ± 3 Ma (2 s , n = 78, MSWD = 1.3) by LA‐ICP‐MS. In contrast, darker domains display heterogeneous trace element and ages, rendering them unsuitable as RMs for microbeam U‐Pb dating.
- 23 June 2026
- Published by Wiley in Geostandards and Geoanalytical Research
Systematic Characterisation of Natural Titanite Reference Materials (Ontario, T3 and Pakistan) for High Spatial‐Resolution U‐Pb Microanalysis
Three previously introduced titanites, Ontario, T3 and Pakistan, were evaluated as potential reference materials (RMs) for high spatial‐resolution U‐Pb microanalysis, offering valuable additions to the currently limited suite of titanite RMs. Comprehensive characterisation through microanalytical techniques, including scanning electron microscope, electron probe micro‐analysis, secondary ion mass spectrometry (SIMS) and laser ablation‐inductively coupled plasma‐mass spectrometry (LA‐ICP‐MS), reveal that the Proterozoic‐age Ontario titanite is inclusion‐free and homogeneous within analytical uncertainty in terms of major and trace elements, U‐Pb isotopes and U‐Pb ages. The Miocene‐age Pakistan titanite, though relatively low in U and Pb contents, also shows homogeneity in U‐Pb isotopes and ages at the scale of analytical precision. Isotope dilution thermal ionisation mass spectrometry (ID‐TIMS) results are reported for the first time for both Ontario and Pakistan titanites. Accordingly, analyses of the Ontario titanite fragments range from concordant to variably discordant but yield a robust weighted mean 207 Pb/ 206 Pb date of 1048.5 ± 3.3 Ma (2 s “internal” uncertainty, n = 9). Cross‐calibration with other titanite RMs by LA‐ICP‐MS demonstrates that Ontario is suitable as a primary RM for determining U‐Pb ages of titanite ranging in age from Precambrian to Neogene. ID‐TIMS analyses of the Pakistan titanite yield overlapping data with a weighted mean 206 Pb/ 238 U date of 20.759 ± 0.055 Ma (2 s “internal” uncertainty, n = 10). Considering its relatively young age, Pakistan titanite is recommended as a secondary RM for quality control of young titanites dating by LA‐ICP‐MS and SIMS. In contrast, the T3 titanite exhibits significant intra‐ and inter‐grain heterogeneity. The brighter zone in BSE images (T3‐LG) has relatively high and homogeneous rare earth elements contents and yields a lower intercept age of 1099 ± 3 Ma (2 s , n = 78, MSWD = 1.3) by LA‐ICP‐MS. In contrast, darker domains display heterogeneous trace element and ages, rendering them unsuitable as RMs for microbeam U‐Pb dating.
- Open Access
- 6 November 2023
- Published by Elsevier in Ore Geology Reviews
- Vol. 163
Trace-element analysis and radiometric dating by inductively coupled plasma–tandem mass spectrometry: Approaches and applications to metallogeny
- 6 November 2023
- Published by Elsevier in Ore Geology Reviews
- Vol. 163
Open AccessTrace-element analysis and radiometric dating by inductively coupled plasma–tandem mass spectrometry: Approaches and applications to metallogeny
- 27 February 2019
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 34 (6) , 1256-1262
Accurate and precise determination of Lu and Hf contents and Hf isotopic composition at the sub-nanogram level in geological samples using MC-ICP-MS
We describe protocols for highly reproducible analysis of Lu and Hf contents and Hf isotopic composition at sub-nanogram levels in geological samples by MC-ICP-MS. Powdered samples were spiked with a 176Lu–180Hf enriched tracer and completely digested using conventional HF, HNO3 and HClO4 acid dissolution protocols. Fluoride salts were dissolved during a final H3BO3 digestion and chemical purification was performed using a single Eichrom Technologies Ln resin. All measurements were carried out on a Neptune Plus MC-ICP-MS employing an Aridus II desolvator. In order to demonstrate the robustness of the proposed protocol, six rock reference materials (RMs) were analysed, spanning various rock types with very low Lu and Hf contents (from nanogram to sub ng g−1 levels). The results are in good agreement within uncertainty with published values for the analysed RMs. Relative to other approaches and low-blank levels, this protocol has great potential for Lu–Hf analysis of low volume (100–500 mg) samples in geochemistry, cosmochemistry and environmental sciences (e.g., peridotite, garnet, meteorites, dust, etc.).
- 27 February 2019
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 34 (6) , 1256-1262
Accurate and precise determination of Lu and Hf contents and Hf isotopic composition at the sub-nanogram level in geological samples using MC-ICP-MS
We describe protocols for highly reproducible analysis of Lu and Hf contents and Hf isotopic composition at sub-nanogram levels in geological samples by MC-ICP-MS. Powdered samples were spiked with a 176Lu–180Hf enriched tracer and completely digested using conventional HF, HNO3 and HClO4 acid dissolution protocols. Fluoride salts were dissolved during a final H3BO3 digestion and chemical purification was performed using a single Eichrom Technologies Ln resin. All measurements were carried out on a Neptune Plus MC-ICP-MS employing an Aridus II desolvator. In order to demonstrate the robustness of the proposed protocol, six rock reference materials (RMs) were analysed, spanning various rock types with very low Lu and Hf contents (from nanogram to sub ng g−1 levels). The results are in good agreement within uncertainty with published values for the analysed RMs. Relative to other approaches and low-blank levels, this protocol has great potential for Lu–Hf analysis of low volume (100–500 mg) samples in geochemistry, cosmochemistry and environmental sciences (e.g., peridotite, garnet, meteorites, dust, etc.).