Richard C. Burgess
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Richard C. Burgess has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
Andreas V. Alexopoulos
Epilepsy Center, Cleveland Clinic, OH, USA
7 shared publicationsJohn C. Mosher
Cleveland Clinic, Epilepsy Center, Cleveland, OH, 44195, USA
6 shared publicationsYosuke Kakisaka
Tohoku University, Department of Pediatrics, School of Medicine, Sendai, Miyagi 980-8574, Japan
6 shared publicationsZhong I. Wang
Epilepsy Center, Department of Neurology, The Cleveland Clinic, Cleveland, OH 44195, USA
5 shared publicationsAnne-Sophie Dubarry
Epilepsy Center, Department of Neurology, The Cleveland Clinic, Cleveland, OH 44195, USA
3 shared publicationsAjay Gupta
Epilepsy Center, Department of Neurology The Cleveland Clinic, Cleveland, OH 44195, USA
2 shared publications
Latest Publications
- 3 August 2026
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
Source Localization of Subclinical Rhythmic EEG Discharge of Adult Using Magnetoencephalography
Purpose: Subclinical rhythmic EEG discharge of adult (SREDA) is a rare, benign EEG phenomenon. To date, no studies have reported the analysis of SREDA using magnetoencephalography (MEG). Here, we report MEG source localization of SREDA in two patients. Methods: MEG-EEG recordings of two patients with SREDA were analyzed using the single equivalent current dipole model with sequential dipole analysis. Results: The source localization results of SREDA discharges in two patients were asynchronous activity between the right and left hemispheres. The early portions of the SREDA episodes were localized to the posterior temporo-perisylvian regions (superior temporal sulcus and temporal operculum), whereas later components localized to the lateral parietal cortex, including the parietal operculum. In both cases, although the SREDA EEG activities were alarming, MEG SREDA activity had little change in frequency, morphology, distribution, abrupt ending, and no associated focal slowing activity or after going slow wave activity. Conclusions: The consistent MEG waveform and localization of the SREDA discharges reported in the two cases suggest neurophysiological mechanisms arising from the posterior supra and infra perisylvian regions, including the parietal operculum, which is not matched with watershed vascular territory. Despite the alarming appearance of SREDA in EEG, MEG waveforms were subtle in both patients. MEG has unique advantages to assess benign SREDA, which requires exceptional caution to avoid misdiagnosis.
- 3 August 2026
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
Source Localization of Subclinical Rhythmic EEG Discharge of Adult Using Magnetoencephalography
Purpose: Subclinical rhythmic EEG discharge of adult (SREDA) is a rare, benign EEG phenomenon. To date, no studies have reported the analysis of SREDA using magnetoencephalography (MEG). Here, we report MEG source localization of SREDA in two patients. Methods: MEG-EEG recordings of two patients with SREDA were analyzed using the single equivalent current dipole model with sequential dipole analysis. Results: The source localization results of SREDA discharges in two patients were asynchronous activity between the right and left hemispheres. The early portions of the SREDA episodes were localized to the posterior temporo-perisylvian regions (superior temporal sulcus and temporal operculum), whereas later components localized to the lateral parietal cortex, including the parietal operculum. In both cases, although the SREDA EEG activities were alarming, MEG SREDA activity had little change in frequency, morphology, distribution, abrupt ending, and no associated focal slowing activity or after going slow wave activity. Conclusions: The consistent MEG waveform and localization of the SREDA discharges reported in the two cases suggest neurophysiological mechanisms arising from the posterior supra and infra perisylvian regions, including the parietal operculum, which is not matched with watershed vascular territory. Despite the alarming appearance of SREDA in EEG, MEG waveforms were subtle in both patients. MEG has unique advantages to assess benign SREDA, which requires exceptional caution to avoid misdiagnosis.
- 26 February 2026
- Published by Elsevier in Neuroimaging Clinics Of North America
- Vol. 36 (2) , 351-366
Magnetoencephalography in Epilepsy
- 26 February 2026
- Published by Elsevier in Neuroimaging Clinics Of North America
- Vol. 36 (2) , 351-366
Magnetoencephalography in Epilepsy
- 19 October 2022
- Published by Elsevier in Clinical Neurophysiology
- Vol. 145, 108-118
Clinical significance of ictal magnetoencephalography in patients undergoing epilepsy surgery
- 19 October 2022
- Published by Elsevier in Clinical Neurophysiology
- Vol. 145, 108-118
Clinical significance of ictal magnetoencephalography in patients undergoing epilepsy surgery
- 11 February 2022
- Published by Elsevier in Epilepsy Research
- Vol. 181, 106886
Epilepsy with Eyelid myoclonias − A diagnosis concealed in other genetic generalized epilepsies with photoparoxysmal response
- 11 February 2022
- Published by Elsevier in Epilepsy Research
- Vol. 181, 106886
Epilepsy with Eyelid myoclonias − A diagnosis concealed in other genetic generalized epilepsies with photoparoxysmal response
- 1 November 2020
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 37 (6) , 545-553
MEG Reporting
The report generated by the magnetoencephalographer's interpretation of the patient's magnetoencephalography examination is the magnetoencephalography laboratory's most important product and is a representation of the quality of the laboratory and the clinical acumen of the personnel. A magnetoencephalography report is not meant to enumerate all the technical details that went into the test nor to fulfill some imagined requirements of the electronic health record. It is meant to clearly and concisely answer the clinical question posed by the referring doctor and to convey the key findings that may inform the next step in the patient's care. The graphical component of a magnetoencephalography report is ordinarily the most welcomed by the referring doctor. Much of the text of the report may be glossed over, so the illustrations must be sufficiently annotated to provide clear and unambiguous findings. The particular images chosen for the report will be a function of the analysis software but should be selected and edited for maximum clarity. There should be a composite pictorial summary slide at the beginning or at the end of the report, which accurately conveys the gist of the report. Along with representative source localizations, reports should contain examples of the simultaneously recorded EEG that enable the referring physician to determine whether epileptic discharges occurred and whether they are consistent with the patient's previously recorded spikes. Information and images (e.g., statistics, magnetic field patterns) that provide convincing evidence of the validity of the source location should also be included.
- 1 November 2020
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 37 (6) , 545-553
MEG Reporting
The report generated by the magnetoencephalographer's interpretation of the patient's magnetoencephalography examination is the magnetoencephalography laboratory's most important product and is a representation of the quality of the laboratory and the clinical acumen of the personnel. A magnetoencephalography report is not meant to enumerate all the technical details that went into the test nor to fulfill some imagined requirements of the electronic health record. It is meant to clearly and concisely answer the clinical question posed by the referring doctor and to convey the key findings that may inform the next step in the patient's care. The graphical component of a magnetoencephalography report is ordinarily the most welcomed by the referring doctor. Much of the text of the report may be glossed over, so the illustrations must be sufficiently annotated to provide clear and unambiguous findings. The particular images chosen for the report will be a function of the analysis software but should be selected and edited for maximum clarity. There should be a composite pictorial summary slide at the beginning or at the end of the report, which accurately conveys the gist of the report. Along with representative source localizations, reports should contain examples of the simultaneously recorded EEG that enable the referring physician to determine whether epileptic discharges occurred and whether they are consistent with the patient's previously recorded spikes. Information and images (e.g., statistics, magnetic field patterns) that provide convincing evidence of the validity of the source location should also be included.
- 13 August 2020
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 37 (6) , 508-517
Recognizing and Correcting MEG Artifacts
Summary: Noise sources in magnetoencephalography (MEG) include: (1) interference from outside the shielded room, (2) other people and devices inside the shielded room, (3) physiologic or nonphysiologic sources inside the patient, (4) activity from inside the head that is unrelated to the signal of interest, (5) intrinsic sensor and recording electronics noise, and (6) artifacts from other apparatus used during recording such as evoked response stimulators. There are other factors which corrupt MEG recording and interpretation and should also be considered “artifacts”: (7) inadequate positioning of the patient, (8) changes in the head position during the recording, (9) incorrect co-registration, (10) spurious signals introduced during postprocessing, and (11) errors in fitting. The major means whereby magnetic interference can be reduced or eliminated are by recording inside a magnetically shielded room, using gradiometers that measure differential magnetic fields, real-time active compensation using reference sensors, and postprocessing with advanced spatio-temporal filters. Many of the artifacts that plague MEG are also seen in EEG, so an experienced electroencephalographer will have the advantage of being able to transfer his knowledge about artifacts to MEG. However, many of the procedures and software used during acquisition and analysis maythemselvescontribute artifact or distortion that must be recognized or prevented. In summary, MEG artifacts are not worse than EEG artifacts, but many aredifferent, and—as with EEG—must be attended to.
- 13 August 2020
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 37 (6) , 508-517
Recognizing and Correcting MEG Artifacts
Summary: Noise sources in magnetoencephalography (MEG) include: (1) interference from outside the shielded room, (2) other people and devices inside the shielded room, (3) physiologic or nonphysiologic sources inside the patient, (4) activity from inside the head that is unrelated to the signal of interest, (5) intrinsic sensor and recording electronics noise, and (6) artifacts from other apparatus used during recording such as evoked response stimulators. There are other factors which corrupt MEG recording and interpretation and should also be considered “artifacts”: (7) inadequate positioning of the patient, (8) changes in the head position during the recording, (9) incorrect co-registration, (10) spurious signals introduced during postprocessing, and (11) errors in fitting. The major means whereby magnetic interference can be reduced or eliminated are by recording inside a magnetically shielded room, using gradiometers that measure differential magnetic fields, real-time active compensation using reference sensors, and postprocessing with advanced spatio-temporal filters. Many of the artifacts that plague MEG are also seen in EEG, so an experienced electroencephalographer will have the advantage of being able to transfer his knowledge about artifacts to MEG. However, many of the procedures and software used during acquisition and analysis maythemselvescontribute artifact or distortion that must be recognized or prevented. In summary, MEG artifacts are not worse than EEG artifacts, but many aredifferent, and—as with EEG—must be attended to.
- 1 May 2020
- Published by Elsevier in Neuroimaging Clinics Of North America
- Vol. 30 (2) , 145-158
MEG for Greater Sensitivity and More Precise Localization in Epilepsy
- 1 May 2020
- Published by Elsevier in Neuroimaging Clinics Of North America
- Vol. 30 (2) , 145-158
MEG for Greater Sensitivity and More Precise Localization in Epilepsy
- 27 September 2019
- Published by Oxford University Press (OUP) in Brain
- Vol. 142 (10) , 2897-2900
Clinical MEG passes another milestone
This scientific commentary refers to ‘Magnetoencephalography for epileptic focus localization in a series of 1000 cases’, by Rampp et al. (doi:10.1093/brain/awz231).
- 27 September 2019
- Published by Oxford University Press (OUP) in Brain
- Vol. 142 (10) , 2897-2900
Clinical MEG passes another milestone
This scientific commentary refers to ‘Magnetoencephalography for epileptic focus localization in a series of 1000 cases’, by Rampp et al. (doi:10.1093/brain/awz231).
- 1 January 2019
- Published by Elsevier
- Vol. 160, 203-214
Magnetoencephalography for localizing and characterizing the epileptic focus
- 1 January 2019
- Published by Elsevier
- Vol. 160, 203-214
Magnetoencephalography for localizing and characterizing the epileptic focus