Károly Pap
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Károly Pap has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Gábor Szebényi
Department of Polymer Engineering, Faculty of Mechanical Engineering Budapest University of Technology and Economics Budapest Hungary
4 shared publications - Rita Maria Kiss
Faculty of Mechanical Engineering, Department of Mechatronics, Optics and Engineering Informatics, Budapest University of Technology and Economics, Budapest, Hungary
4 shared publications Bence Abonyi
2 shared publications- Andrea Gajtkó
Department of Anatomy, Histology and Embryology, Faculty of Medicine, University of Debrecen, H-4032 Debrecen, Hungary
1 shared publication - Atilla F. Karácsony
Department of Traumatology, Semmelweis University Budapest, Budapest, Hungary
1 shared publication - Balázs Gereben
Department of Endocrine Neurobiology, Institute of Experimental Medicine, Hungarian Academy of Sciences, Budapest, Hungary
1 shared publication
Latest Publications
- Open Access
- 17 March 2025
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Research
- Vol. 14 (3) , 270-280
Changes in the mechanical properties of tibialis anterior and peroneus longus allograft depending on sterilization method and storage time
Aims: The aim of the present research was to analyze the effects of different sterilization methods and storage times on the mechanical properties (load at first break, strain at first break, maximum load, strain at maximum load, and Young’s modulus of elasticity) of different allografts compared to native groups.Methods: Two types of grafts were harvested from human cadavers: 165 tibialis anterior (TA) and 166 peroneus longus (PL) tendons. According to the two types of sterilization methods (γ and electron beam irradiation) or the lack of one, and the six types of storage time (one to six months), 36 groups were created. In addition, we created a 1 to 1 native group, which was not sterilized and stored, tested within four hours of collection.Results: In the results of tendon type TA compared to TA native group, we observed significant differences at the fifth month of storage for all measured parameters. Load at first break of the frozen values at the fifth month was significantly inferior to the native group (p = 0.034). For strain at first break and strain at maximum load, all sterilization methods were significantly inferior at the fifth month (p = 0.003 to p = 0.009). Maximum load values were significantly superior with E-beam irradiation at the fifth month (p = 0.003), and also significantly higher with γ irradiation at the fifth month (p = 0.009). Young’s modulus showed significantly inferior values in the frozen tendons at the fifth month (p = 0.001 to p = 0.003). In tendon type PL, no significant differences were found for any of the tested parameters compared to the native group.Conclusion: Our results indicate that freezing alters mechanical properties via the decrease seen in the ultimate tensile strength. In addition, at the fifth and sixth months of storage, time could notably affect allografts rather than the sterilization procedures.Cite this article: Bone Joint Res 2025;14(3):270–280.
- 17 March 2025
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Research
- Vol. 14 (3) , 270-280
Open AccessChanges in the mechanical properties of tibialis anterior and peroneus longus allograft depending on sterilization method and storage time
Aims: The aim of the present research was to analyze the effects of different sterilization methods and storage times on the mechanical properties (load at first break, strain at first break, maximum load, strain at maximum load, and Young’s modulus of elasticity) of different allografts compared to native groups.Methods: Two types of grafts were harvested from human cadavers: 165 tibialis anterior (TA) and 166 peroneus longus (PL) tendons. According to the two types of sterilization methods (γ and electron beam irradiation) or the lack of one, and the six types of storage time (one to six months), 36 groups were created. In addition, we created a 1 to 1 native group, which was not sterilized and stored, tested within four hours of collection.Results: In the results of tendon type TA compared to TA native group, we observed significant differences at the fifth month of storage for all measured parameters. Load at first break of the frozen values at the fifth month was significantly inferior to the native group (p = 0.034). For strain at first break and strain at maximum load, all sterilization methods were significantly inferior at the fifth month (p = 0.003 to p = 0.009). Maximum load values were significantly superior with E-beam irradiation at the fifth month (p = 0.003), and also significantly higher with γ irradiation at the fifth month (p = 0.009). Young’s modulus showed significantly inferior values in the frozen tendons at the fifth month (p = 0.001 to p = 0.003). In tendon type PL, no significant differences were found for any of the tested parameters compared to the native group.Conclusion: Our results indicate that freezing alters mechanical properties via the decrease seen in the ultimate tensile strength. In addition, at the fifth and sixth months of storage, time could notably affect allografts rather than the sterilization procedures.Cite this article: Bone Joint Res 2025;14(3):270–280.
- Open Access
- 4 January 2023
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24 (2) , 918
Unique, Specific CART Receptor-Independent Regulatory Mechanism of CART(55-102) Peptide in Spinal Nociceptive Transmission and Its Relation to Dipeptidyl-Peptidase 4 (DDP4)
Cocaine- and amphetamine-regulated transcript (CART) peptides are involved in several physiological and pathological processes, but their mechanism of action is unrevealed due to the lack of identified receptor(s). We provided evidence for the antihyperalgesic effect of CART(55-102) by inhibiting dipeptidyl-peptidase 4 (DPP4) in astrocytes and consequently reducing neuroinflammation in the rat spinal dorsal horn in a carrageenan-evoked inflammation model. Both naturally occurring CART(55-102) and CART(62-102) peptides are present in the spinal cord. CART(55-102) is not involved in acute nociception but regulates spinal pain transmission during peripheral inflammation. While the full-length peptide with a globular motif contributes to hyperalgesia, its N-terminal inhibits this process. Although the anti-hyperalgesic effects of CART(55-102), CART(55-76), and CART(62-76) are blocked by opioid receptor antagonists in our inflammatory models, but not in neuropathic Seltzer model, none of them bind to any opioid or G-protein coupled receptors. DPP4 interacts with Toll-like receptor 4 (TLR4) signalling in spinal astrocytes and enhances the TLR4-induced expression of interleukin-6 and tumour necrosis factor alpha contributing to inflammatory pain. Depending on the state of inflammation, CART(55-102) is processed in the spinal cord, resulting in the generation of biologically active isoleucine-proline-isoleucine (IPI) tripeptide, which inhibits DPP4, leading to significantly decreased glia-derived cytokine production and hyperalgesia.
- 4 January 2023
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24 (2) , 918
Open AccessUnique, Specific CART Receptor-Independent Regulatory Mechanism of CART(55-102) Peptide in Spinal Nociceptive Transmission and Its Relation to Dipeptidyl-Peptidase 4 (DDP4)
Cocaine- and amphetamine-regulated transcript (CART) peptides are involved in several physiological and pathological processes, but their mechanism of action is unrevealed due to the lack of identified receptor(s). We provided evidence for the antihyperalgesic effect of CART(55-102) by inhibiting dipeptidyl-peptidase 4 (DPP4) in astrocytes and consequently reducing neuroinflammation in the rat spinal dorsal horn in a carrageenan-evoked inflammation model. Both naturally occurring CART(55-102) and CART(62-102) peptides are present in the spinal cord. CART(55-102) is not involved in acute nociception but regulates spinal pain transmission during peripheral inflammation. While the full-length peptide with a globular motif contributes to hyperalgesia, its N-terminal inhibits this process. Although the anti-hyperalgesic effects of CART(55-102), CART(55-76), and CART(62-76) are blocked by opioid receptor antagonists in our inflammatory models, but not in neuropathic Seltzer model, none of them bind to any opioid or G-protein coupled receptors. DPP4 interacts with Toll-like receptor 4 (TLR4) signalling in spinal astrocytes and enhances the TLR4-induced expression of interleukin-6 and tumour necrosis factor alpha contributing to inflammatory pain. Depending on the state of inflammation, CART(55-102) is processed in the spinal cord, resulting in the generation of biologically active isoleucine-proline-isoleucine (IPI) tripeptide, which inhibits DPP4, leading to significantly decreased glia-derived cytokine production and hyperalgesia.
- Open Access
- 26 October 2022
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 21 (6) , 1803-1823
Nonlinear fiber-bundle-cells-based phenomenological modeling of human tissue samples
Certain assemblies of fibers, called fiber bundles, play a crucial role in the statistical macroscale properties of fibrous structures like natural or artificial materials. Based on the concept of using idealized statistical fiber bundle cells (FBCs) as model elements, the software named FiberSpace was developed by us earlier for the phenomenological modeling of the tensile test process of real fibrous structures. The model fibers of these FBCs had been considered linear elastic, which was suitable for modeling certain textiles and composites. However, the biological tissues are multilevel structures with fiber-like building elements on every structural level where the fiber elements on the dominant level are statistical bundles of elementary fibers. Hence, their modeling required us to introduce model fibers of nonlinear mechanical behavior and derive the proper mathematical formulas for the calculation of the expected tensile force processes of the FBCs. Accordingly, we developed a new version of FiberSpace. The proposed nonlinear FBCs-based modeling method is essentially phenomenological that decomposes the measured and averaged stress–strain curve into the weighted sum of the responses of different idealized nonlinear FBCs. However, this decomposition can give certain information about the fibrous structure and some details of its damage and failure sub-processes. A special application of nonlinear E-bundles, where the measured stress–strain curve is expanded into a product-function series, may give another type of description for the failure process and can be applied to single measurements of structured failure process containing significant peaks and drops as well. The fitted phenomenological FBC models provide a decomposition of the measured force–strain curve, which enables to construct informative damage and failure maps. The applicability of the phenomenological modeling method and the fitting procedure is demonstrated with the tensile test data of some human and animal tissues, such as facial nerves and tendons.
- 26 October 2022
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 21 (6) , 1803-1823
Open AccessNonlinear fiber-bundle-cells-based phenomenological modeling of human tissue samples
Certain assemblies of fibers, called fiber bundles, play a crucial role in the statistical macroscale properties of fibrous structures like natural or artificial materials. Based on the concept of using idealized statistical fiber bundle cells (FBCs) as model elements, the software named FiberSpace was developed by us earlier for the phenomenological modeling of the tensile test process of real fibrous structures. The model fibers of these FBCs had been considered linear elastic, which was suitable for modeling certain textiles and composites. However, the biological tissues are multilevel structures with fiber-like building elements on every structural level where the fiber elements on the dominant level are statistical bundles of elementary fibers. Hence, their modeling required us to introduce model fibers of nonlinear mechanical behavior and derive the proper mathematical formulas for the calculation of the expected tensile force processes of the FBCs. Accordingly, we developed a new version of FiberSpace. The proposed nonlinear FBCs-based modeling method is essentially phenomenological that decomposes the measured and averaged stress–strain curve into the weighted sum of the responses of different idealized nonlinear FBCs. However, this decomposition can give certain information about the fibrous structure and some details of its damage and failure sub-processes. A special application of nonlinear E-bundles, where the measured stress–strain curve is expanded into a product-function series, may give another type of description for the failure process and can be applied to single measurements of structured failure process containing significant peaks and drops as well. The fitted phenomenological FBC models provide a decomposition of the measured force–strain curve, which enables to construct informative damage and failure maps. The applicability of the phenomenological modeling method and the fitting procedure is demonstrated with the tensile test data of some human and animal tissues, such as facial nerves and tendons.
- Open Access
- 4 August 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (15) , 5369
Evaluation of the Effect of Freezing and Gamma Irradiation on Different Types of Tendon Allografts by DIC Assisted Tensile Testing
This study aimed to evaluate the changes in the endurance properties of four types of tendons caused by freezing and gamma irradiation. Four types of grafts were harvested: quadriceps, semitendinosus + gracilis, tibialis anterior, and peroneus longus. These were put into three groups: Group A was the control group, tested without freezing or irradiation. Grafts in Group B were frozen and irradiated (target dose: 21 kGy), while grafts in Group C were again frozen and irradiated (target dose: 42 kGy). Maximum load, tensile modulus, tensile strength, strain at maximum force and fracture strain were calculated from the force-elongation graphs of cyclic load tests. The higher gamma irradiation dose (Group C) significantly decreased the strains at tensile strength of the quadriceps tendons (p = 0.0004–0.0237), compared to the other two groups. In the case of the quadricep tendons (p = 0.0151), there is a significant decrease in Young’s modulus after gamma irradiation with the dose of 42 kGy. According to the results of the study, the tibialis anterior and the peroneus longus are recommended in ACL reconstruction when gamma irradiation is required, while quadricep tendons, which are usually used for an autograph, are not suitable for allograft reconstruction after gamma irradiation from the viewpoint of mechanical properties.
- 4 August 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (15) , 5369
Open AccessEvaluation of the Effect of Freezing and Gamma Irradiation on Different Types of Tendon Allografts by DIC Assisted Tensile Testing
This study aimed to evaluate the changes in the endurance properties of four types of tendons caused by freezing and gamma irradiation. Four types of grafts were harvested: quadriceps, semitendinosus + gracilis, tibialis anterior, and peroneus longus. These were put into three groups: Group A was the control group, tested without freezing or irradiation. Grafts in Group B were frozen and irradiated (target dose: 21 kGy), while grafts in Group C were again frozen and irradiated (target dose: 42 kGy). Maximum load, tensile modulus, tensile strength, strain at maximum force and fracture strain were calculated from the force-elongation graphs of cyclic load tests. The higher gamma irradiation dose (Group C) significantly decreased the strains at tensile strength of the quadriceps tendons (p = 0.0004–0.0237), compared to the other two groups. In the case of the quadricep tendons (p = 0.0151), there is a significant decrease in Young’s modulus after gamma irradiation with the dose of 42 kGy. According to the results of the study, the tibialis anterior and the peroneus longus are recommended in ACL reconstruction when gamma irradiation is required, while quadricep tendons, which are usually used for an autograph, are not suitable for allograft reconstruction after gamma irradiation from the viewpoint of mechanical properties.
- 1 August 2018
- Published by Joint Diseases and Related Surgery in Eklem Hastalik Cerrahisi
- Vol. 29 (2) , 65-70
Evaluation of clinical outcomes of cemented vs uncemented knee prostheses covered with titanium plasma spray and hydroxyapatite: A minimum two years follow-up
In this study, we introduce the SanatSwing cementless total knee prosthesis coated with a combination of titanium plasma spray and hydroxyapatite porous coating and compared its early results to the SanatSwing cemented knee prosthesis. We compared 278 patients, who underwent total knee replacement between September 2012 and February 2017. A total of 142 patients (Group A; 78 male, 64 female, mean age 69±14) were implanted a cemented SanatSwing and 136 patients (Group B; 83 male, 53 female, mean age 59±10), a cementless SanatSwing knee prosthesis was implanted. Implant position and periprosthetic bone conditions were investigated over time on radiographs after a mean follow-up period of two years. Range of motion, pain level, distance of painless walk, and the ability to climb stairs were evaluated. Significant improvement was observed in both the cemented and uncemented groups when the preoperative scores were compared to the scores of their final visit, but we did not find any difference in measured scores between the cemented and uncemented group. Complication rates were low and almost similar in both groups without any significant difference. We used the combination of titanium plasma spray and the hydroxyapatite porous coating technique in cementless prostheses. Our results showed us that the novel SanatSwing cementless total knee prosthesis could be a great alternative to cemented total knee arthroplasty.
- 1 August 2018
- Published by Joint Diseases and Related Surgery in Eklem Hastalik Cerrahisi
- Vol. 29 (2) , 65-70
Evaluation of clinical outcomes of cemented vs uncemented knee prostheses covered with titanium plasma spray and hydroxyapatite: A minimum two years follow-up
In this study, we introduce the SanatSwing cementless total knee prosthesis coated with a combination of titanium plasma spray and hydroxyapatite porous coating and compared its early results to the SanatSwing cemented knee prosthesis. We compared 278 patients, who underwent total knee replacement between September 2012 and February 2017. A total of 142 patients (Group A; 78 male, 64 female, mean age 69±14) were implanted a cemented SanatSwing and 136 patients (Group B; 83 male, 53 female, mean age 59±10), a cementless SanatSwing knee prosthesis was implanted. Implant position and periprosthetic bone conditions were investigated over time on radiographs after a mean follow-up period of two years. Range of motion, pain level, distance of painless walk, and the ability to climb stairs were evaluated. Significant improvement was observed in both the cemented and uncemented groups when the preoperative scores were compared to the scores of their final visit, but we did not find any difference in measured scores between the cemented and uncemented group. Complication rates were low and almost similar in both groups without any significant difference. We used the combination of titanium plasma spray and the hydroxyapatite porous coating technique in cementless prostheses. Our results showed us that the novel SanatSwing cementless total knee prosthesis could be a great alternative to cemented total knee arthroplasty.
- Open Access
- 2 February 2018
- Published by Juniper Publishers in Orthopedics and Rheumatology Open Access Journal
- Vol. 10 (3)
Dilemma of the Orthopedic Surgeon - What kind of Graft should we use for ACL Reconstruction?
Journal of orthopaedics is an international, peer reviewed scientific journal focused towards publishing a complete and reliable source of information on the innovations and ongoing developments in the field of Orthopedics which includes extensive study in the fields of Hand surgery.
- 2 February 2018
- Published by Juniper Publishers in Orthopedics and Rheumatology Open Access Journal
- Vol. 10 (3)
Open AccessDilemma of the Orthopedic Surgeon - What kind of Graft should we use for ACL Reconstruction?
Journal of orthopaedics is an international, peer reviewed scientific journal focused towards publishing a complete and reliable source of information on the innovations and ongoing developments in the field of Orthopedics which includes extensive study in the fields of Hand surgery.
- 15 November 2016
- Published by Springer Nature in International Orthopaedics
- Vol. 41 (2) , 357-365
Does a different dose of gamma irradiation have the same effect on five different types of tendon allografts? — a biomechanical study
Introduction The goals of our study were to evaluate the biomechanical differences between five tendons and the changes in biomechanical properties caused by irradiation. Methods Achilles, quadriceps, semitendinosus + gracilis (STG), tibialis anterior (TA) and the peroneus longus (PL) were harvested from 30 donors. Group A contained 50 tendons without gamma irradiation. The groups were irradiated with a dose of 21 kGy (group B 50 tendons) and with a dose of 42 kGy (group C 50 tendons). The grafts were soaked in a radio-protectant solution and frozen at −80 °C. Cyclic loading tests were performed followed by load to failure tests. Young modulus of elasticity, maximum force, strain at tensile strength and strain at rupture were calculated. Results The Achilles tendons had significantly lower Young modulus than the TA (p = 0.0036) in group A. The Achilles showed significantly lower than PL (p = 0.000042) and TA (p = 0.00142) in group B and C. The quadriceps and the ST (p = 0.0037) provided poorer values than the TA (p = 0.0432) in group C. We found no difference in maximum loads among the tendons in group A. The maximum load of the Achilles and quadriceps showed better results than the PL (p = 0.0016), (p = 0.0018) and the STG (p = 0.0066), (p = 0.0019) in group C. The TA had similar results like the Achilles and quadriceps. Discussion and conclusions The vulnerability of gamma irradiation of TA was less than Achilles and quadriceps tendons.
- 15 November 2016
- Published by Springer Nature in International Orthopaedics
- Vol. 41 (2) , 357-365
Does a different dose of gamma irradiation have the same effect on five different types of tendon allografts? — a biomechanical study
Introduction The goals of our study were to evaluate the biomechanical differences between five tendons and the changes in biomechanical properties caused by irradiation. Methods Achilles, quadriceps, semitendinosus + gracilis (STG), tibialis anterior (TA) and the peroneus longus (PL) were harvested from 30 donors. Group A contained 50 tendons without gamma irradiation. The groups were irradiated with a dose of 21 kGy (group B 50 tendons) and with a dose of 42 kGy (group C 50 tendons). The grafts were soaked in a radio-protectant solution and frozen at −80 °C. Cyclic loading tests were performed followed by load to failure tests. Young modulus of elasticity, maximum force, strain at tensile strength and strain at rupture were calculated. Results The Achilles tendons had significantly lower Young modulus than the TA (p = 0.0036) in group A. The Achilles showed significantly lower than PL (p = 0.000042) and TA (p = 0.00142) in group B and C. The quadriceps and the ST (p = 0.0037) provided poorer values than the TA (p = 0.0432) in group C. We found no difference in maximum loads among the tendons in group A. The maximum load of the Achilles and quadriceps showed better results than the PL (p = 0.0016), (p = 0.0018) and the STG (p = 0.0066), (p = 0.0019) in group C. The TA had similar results like the Achilles and quadriceps. Discussion and conclusions The vulnerability of gamma irradiation of TA was less than Achilles and quadriceps tendons.
- 1 March 2016
- Published by Akademiai Kiado Zrt. in Acta Physiologica Hungarica
- Vol. 103 (1) , 86-93
Pitfalls during biomechanical testing — Evaluation of different fixation methods for measuring tendons endurance properties
The goal of the study was to find a proper technique to fix tendon grafts into an INSTRON loading machine. From 8 human cadavers, 40 grafts were collected. We removed the bone-patella tendon-bone grafts, the semitendinosus and gracilis tendons, the quadriceps tendon-bone grafts, the Achilles tendons, and the peroneus longus tendons from each lower extremity. We tested the tendon grafts with five different types of fixation devices: surgical thread (Premicron 3), general mounting clamp, wire mesh, cement fixation, and a modified clamp for an INSTRON loading machine. The mean failure load in case of surgical thread fixation was (381N ± 26N). The results with the general clamp were (527N ± 45N). The wire meshes were more promising (750N ± 21N), but did not reach the outcomes we desired. Easy slippages of the ends of the tendons from the cement encasements were observed (253N ± 18N). We then began to use Shi’s clamp that could produce 977N ± 416N peak force. We combined Shi’s clamp with freezing of the graft and the rupture of the tendon itself demonstrated an average force of 2198 N ± 773N. We determined that our modified frozen clamp fixed the specimens against high tensile forces.
- 1 March 2016
- Published by Akademiai Kiado Zrt. in Acta Physiologica Hungarica
- Vol. 103 (1) , 86-93
Pitfalls during biomechanical testing — Evaluation of different fixation methods for measuring tendons endurance properties
The goal of the study was to find a proper technique to fix tendon grafts into an INSTRON loading machine. From 8 human cadavers, 40 grafts were collected. We removed the bone-patella tendon-bone grafts, the semitendinosus and gracilis tendons, the quadriceps tendon-bone grafts, the Achilles tendons, and the peroneus longus tendons from each lower extremity. We tested the tendon grafts with five different types of fixation devices: surgical thread (Premicron 3), general mounting clamp, wire mesh, cement fixation, and a modified clamp for an INSTRON loading machine. The mean failure load in case of surgical thread fixation was (381N ± 26N). The results with the general clamp were (527N ± 45N). The wire meshes were more promising (750N ± 21N), but did not reach the outcomes we desired. Easy slippages of the ends of the tendons from the cement encasements were observed (253N ± 18N). We then began to use Shi’s clamp that could produce 977N ± 416N peak force. We combined Shi’s clamp with freezing of the graft and the rupture of the tendon itself demonstrated an average force of 2198 N ± 773N. We determined that our modified frozen clamp fixed the specimens against high tensile forces.
- 1 January 2015
- Published by Springer Nature
- p. 37-52
Mosaicplasty of Osteochondral Lesions of the Ankle
- 1 January 2015
- Published by Springer Nature
- p. 37-52
Mosaicplasty of Osteochondral Lesions of the Ankle