TFTeresa Ferrer-Blasco

Teresa Ferrer-Blasco

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Teresa Ferrer-Blasco has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Alejandro Cerviño

    Department of Optics & Optometry & Vision Sciences, University of Valencia, Burjassot, Valencia, Spain

    2 shared publications
  • David Madrid-Costa

    Universidad Complutense de Madrid

    2 shared publications
  • Jose Manuel Gonzalez-Meijome

    Clinical and Experimental Optometry Research Lab (CEORLab), School of Science, University of Minho, 4710-057 Braga, Portugal

    2 shared publications
  • José F. Alfonso

    Fernández-Vega, Ophthalmological Institute, Oviedo, Spain

    1 shared publication
  • Robert Montés-Micó

    From the Optometry Research Group (Ferrer-Blasco, Montés-Micó, Cerviño), Optics Department, University of Valencia, Valencia, Spain; the Optica Queiros Lda. Póvoa de Lanhoso (Peixoto-de-Matos), and the Department of Physics (Optometry) (González-Méijome), School of Sciences, University of Minho, Braga, Portugal

    1 shared publication
  • Santiago García

    Optometry Research Group, Department of Optics, University of Valencia, Valencia, Spain

    1 shared publication

Latest Publications

  • Stereoacuity with balanced presbyopic contact lenses

    by Teresa Ferrer‐Blasco, David Madrid‐Costa

    To evaluate near stereoacuity with the balanced Proclear Multifocal simultaneous vision contact lens. Twenty-five presbyopic subjects were fitted binocularly with the Proclear Multifocal contact lens and with distance contact lenses combined with reading spectacles, which served as controls. After one month, stereoacuity was measured using the vectographic Titmus and Random dot stereotests and the Howard-Dolman (HD) apparatus under photopic conditions (85 cd/m(2) ) at 40 cm. Binocular high-contrast visual acuities (BHCVA) at distance and near were examined. For the multifocal group, mean stereoacuity with the Howard-Dolman method was 22.40 ± 8.23 seconds of arc. Using the Titmus and the Random dot sterereotests, the values were 56.40 ± 18.00 and 54.80 ± 20.23 seconds of arc, respectively. For the SCL group, mean stereoacuities were 19.9 ± 4.6, 51.2 ± 16.4 and 51.2 ± 20.88 seconds of arc, with the Howard-Dolman, Titmus and the Random dot, respectively. There were no statistically significant differences among groups for Howard-Dolman (p = 0.07), Titmus (p = 0.10) and Random dot (p = 0.17) stereotests. No statistically significant differences were found between the Titmus and the Random dot stereotest values (multifocal group: p = 0.30 and SCL group: p = 0.50), however, these values differ significantly from those found using the Howard-Dolman method for both groups (p < 0.001). For the multifocal group, BHCVA was -0.007 ± 0.060 and 0.012 ± 0.063 logMAR for distance and near vision, respectively. For the SCL group, these values were -0.02 ± 0.05 and -0.01 ± 0.06 logMAR, for distance and near vision, respectively. Comparing both groups there were no statistically significant differences between groups for either distance (p = 0.08) or near (p = 0.09). The Proclear Multifocal contact lens provided good distance and near visual acuity preserving stereopsis. Multifocal optics with one lens biased to distance viewing and the other lens biased toward near viewing minimally affects stereoacuity.


  • Stereoacuity with Simultaneous Vision Multifocal Contact Lenses

    by Teresa Ferrer‐Blasco, David Madrid‐Costa

    Purpose.: To evaluate near stereoacuity (SA) with Focus Progressives and PureVision Multifocal simultaneous vision contact lenses. Methods.: In a cross‐over study design, 20 presbyopic subjects were fitted with either the Focus Progressives or PureVision Multifocal lenses. After 1 month, SA was measured with the vectographic Titmus, Random dot stereotests, and the Howard‐Dolman apparatus under photopic conditions (85 lux) at 40 cm. Binocular high‐contrast visual acuity at distance and near was examined. Subjects were then refitted with the alternative correction and the procedure was repeated. Results.: Mean SA with the Focus Progressive was 21 ± 7 sec arc, 54 ± 17 sec arc, and 51 ± 21 sec arc, with the Howard‐Dolman, Titmus, and Random dot sterereotests, respectively. These values were 25 ± 9 sec arc, 74 ± 26 sec arc, and 82 ± 26 sec arc with the PureVision Multifocal, respectively. SA was better with the Focus Progressives compared with the PureVision using the Howard‐Dolman (4 sec arc of difference; p = 0.001), Titmus (2 sec arc of difference; p = 0.001), and Random dot (31 sec arc of difference; p < 0.001) tests. Binocular mean high‐contrast distance visual acuity was similar for the Focus Progressives and PureVision Multifocal: −0.01 ± 0.07 and +0.02 ± 0.08 logMAR, respectively (p = 0.074). At near vision, these values were +0.01 ± 0.07 and +0.06 ± 0.06 logMAR, respectively, being statistically significant different (p = 0.004). Conclusions.: Both the Focus Progressive and PureVision Multifocal contact lenses provided good visual acuity preserving stereopsis. Focus Progressives had slightly better near acuity and better SA than the Purevision Multifocal contact lenses. Differences found between the lens types may be related to asphericity, near addition of the contact lens, or even visual acuity differences between the two eyes that were not measured in this study but could conceivably have contributed to SA measure differences. SA measurement with a Howard‐Dolman apparatus reveals better SA than vectographic tests.


  • Effect of partial and full correction of corneal spherical aberration on visual acuity and contrast sensitivity

    by Teresa Ferrer-Blasco

    A 60-year-old white man had cataract surgery with an AcrySof IQ intraocular lens (IOL) implanted in the right eye and a Tecnis IOL implanted in the left eye. The ocular spherical aberration (SA) target for a 6.0 mm pupil was +0.10 microm for the right eye and 0 microm for the left eye. After surgery, the ocular SA in the right eye was significantly higher than that in the left eye (+0.112 microm +/- 0.002 [SD] versus +0.021 +/- 0.003 microm; P<.001). No between-eye difference in the best corrected visual acuity and photopic contrast sensitivity was found. The contrast sensitivity was significantly better in the eye with the AcrySof IQ IOL at 12 and 18 cpd under mesopic conditions. The best contrast sensitivity was achieved in the eye with a residual ocular SA of about +0.10 microm.


  • Top Cited Papers

    Prevalence of corneal astigmatism before cataract surgery

    by Teresa Ferrer-Blasco, Robert Montés-Micó, Sofia C. Peixoto-De-Matos, José M. González-Méijome, Alejandro Cerviño

    To analyze the prevalence and presentation patterns of corneal astigmatism in cataract surgery candidates. University of Valencia, Valencia, Spain. Refractive and keratometric values were measured before surgery in patients having cataract extraction. Descriptive statistics of refractive and keratometric cylinder data were analyzed and correlated by age ranges. Refractive and keratometric data from 4,540 eyes of 2,415 patients (mean age 60.59 years +/- 9.87 [SD]; range 32 to 87 years) differed significantly when the patients were divided into 10-year subsets. There was a trend toward less negative corneal astigmatism values, except the steepest corneal radius and the J(45) vector component, in older groups (Kruskal-Wallis, P<.01). In 13.2% of eyes, no corneal astigmatism was present; in 64.4%, corneal astigmatism was between 0.25 and 1.25 diopters (D) and in 22.2%, it was 1.50 D or higher. Corneal astigmatism less than 1.25 D was present in most cataract surgery candidates; it was higher in about 22%, with slight differences between the various age ranges. This information is useful for intraocular lens (IOL) manufacturers to evaluate which age ranges concentrate the parameters most frequently needed in sphere and cylinder powers and for surgeons to evaluate which IOLs provide the most effective power range.


  • Open Access

    Retinal Straylight Before and After Penetrating Keratoplasty in an Eye with a Post-Herpetic Corneal Scar

    by Teresa Ferrer-Blasco, Alejandro Cerviño, José M. González-Méijome, Santiago García, José F. Alfonso