Kangpu Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kangpu Xu has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Zev Rosenwaks
Ronald O. Perelman and Claudia Cohen Center for Reproductive Medicine and Infertility , Weill Cornell Medical College of Cornell University , 1305 York Avenue, New York, NY 10021 , USA
2 shared publicationsBaoqiang Cao
The Institute for Computational Engineering and Sciences , the University of Texas at Austin , Austin TX 78712 , USA
1 shared publicationBarbara Tazon-Vega
Ronald O. Perelman and Claudia Cohen Center for Reproductive Medicine and Infertility , Weill Cornell Medical College of Cornell University , 1305 York Avenue, New York, NY 10021 , USA
1 shared publicationChenhui Zhang
Ronald O. Perelman and Claudia Cohen Center for Reproductive Medicine and Infertility , Weill Cornell Medical College of Cornell University , 1305 York Avenue, New York, NY 10021 , USA
1 shared publicationDavid H. Abramson
Department of Ophthalmology (K.B., D.H.A.), New York Presbyterian Hospital–Weill Medical College of Cornell University, New York, New York, USA
1 shared publicationGuanglun Zhuang
Center for Reproductive Medicine, First Affiliated Hospital , Sun Yat-sen University , 58 Zhongshan Road II, Guangzhou 510080 , People's Republic of China
1 shared publication
Latest Publications
- 21 June 2012
- Published by Georg Thieme Verlag KG in Seminars in Reproductive Medicine
- Vol. 30 (04) , 259-266
New Perspectives on Embryo Biopsy: Not How, But When and Why?
During the past 2 decades, biopsy for preimplantation genetic diagnosis at three stages, that is, before conception (the first polar body), after fertilization (the second polar body), and early cleavage (D3 blastomeres) or blastocyst stage (D5/D6 trophectoderm biopsy), have been optimized and performed clinically in hundreds of in vitro fertilization centers around the world. Although opening the zona pellucida by mechanical or chemical means is still effectively in use, noncontact laser has become the indispensable instrument. Overall, the invasive nature of biopsy at any given stage is recognized. It is believed that removal of the polar bodies from M-II oocytes and fertilized zygotes may have the least detrimental effects on subsequent embryonic development; hence increasing applications of polar body biopsy are anticipated. Although D3 biopsy is currently the most frequently used method, the effectiveness of D3 cleavage-stage biopsy is unsettling because of the mosaicism in early cleavage human embryos. Controversies exist in several areas; particularly, the efficacy of preimplantation genetic screening based on one cell removed from a D3 embryo remains to be confirmed. With new genetic testing technology, there may be no need to biopsy two cells because accuracy from one cell is high and the risk of misdiagnosis is very low when sufficient markers are used for chromosome copy number assessment or for mutation detection of single-gene disorders. And finally, it appears that limited harm is caused by biopsy at the blastocyst stage and mosaicism seems to be less common as compared with earlier stages. Therefore, use of the blastocyst-stage biopsy combined with cryopreservation protocol can be effectively used for several indications. Furthermore, faster genetic analytical methods that can be completed within several hours will make this strategy more practical and attractive as fresh embryo transfer is possible.
- 21 June 2012
- Published by Georg Thieme Verlag KG in Seminars in Reproductive Medicine
- Vol. 30 (04) , 259-266
New Perspectives on Embryo Biopsy: Not How, But When and Why?
During the past 2 decades, biopsy for preimplantation genetic diagnosis at three stages, that is, before conception (the first polar body), after fertilization (the second polar body), and early cleavage (D3 blastomeres) or blastocyst stage (D5/D6 trophectoderm biopsy), have been optimized and performed clinically in hundreds of in vitro fertilization centers around the world. Although opening the zona pellucida by mechanical or chemical means is still effectively in use, noncontact laser has become the indispensable instrument. Overall, the invasive nature of biopsy at any given stage is recognized. It is believed that removal of the polar bodies from M-II oocytes and fertilized zygotes may have the least detrimental effects on subsequent embryonic development; hence increasing applications of polar body biopsy are anticipated. Although D3 biopsy is currently the most frequently used method, the effectiveness of D3 cleavage-stage biopsy is unsettling because of the mosaicism in early cleavage human embryos. Controversies exist in several areas; particularly, the efficacy of preimplantation genetic screening based on one cell removed from a D3 embryo remains to be confirmed. With new genetic testing technology, there may be no need to biopsy two cells because accuracy from one cell is high and the risk of misdiagnosis is very low when sufficient markers are used for chromosome copy number assessment or for mutation detection of single-gene disorders. And finally, it appears that limited harm is caused by biopsy at the blastocyst stage and mosaicism seems to be less common as compared with earlier stages. Therefore, use of the blastocyst-stage biopsy combined with cryopreservation protocol can be effectively used for several indications. Furthermore, faster genetic analytical methods that can be completed within several hours will make this strategy more practical and attractive as fresh embryo transfer is possible.
- Open Access
- 11 August 2009
- Published by Oxford University Press (OUP) in Molecular Human Reproduction
- Vol. 15 (11) , 739-747
Evaluation of genome coverage and fidelity of multiple displacement amplification from single cells by SNP array
The scarce amount of DNA contained in a singe cell is a limiting factor for clinical application of preimplantation genetic diagnosis mainly due to the risk of misdiagnosis caused by allele dropout and the difficulty in obtaining copy number variations in all 23 pairs of chromosomes. Multiple displacement amplification (MDA) has been reported to generate large quantity of products from small amount of templates. Here, we evaluated the fidelity of whole-genome amplification MDA from single or a few cells and determined the accuracy of chromosome copy number assessment on these MDA products using an Affymetrix 10K 2.0 SNP Mapping Array. An average coverage rate (86.2%) from single cells was obtained and the rates increased significantly when five or more cells were used as templates. Higher concordance for chromosome copy number from single cells could be achieved when the MDA amplified product was used as reference (93.1%) than when gDNA used as reference (82.8%). The present study indicates that satisfactory genome coverage can be obtained from single-cell MDA which may be used for studies where only a minute amount of genetic materials is available. Clinically, MDA coupled with SNP mapping array may provide a reliable and accurate method for chromosome copy number analysis and most likely for the detection of single-gene disorders as well.
- 11 August 2009
- Published by Oxford University Press (OUP) in Molecular Human Reproduction
- Vol. 15 (11) , 739-747
Open AccessEvaluation of genome coverage and fidelity of multiple displacement amplification from single cells by SNP array
The scarce amount of DNA contained in a singe cell is a limiting factor for clinical application of preimplantation genetic diagnosis mainly due to the risk of misdiagnosis caused by allele dropout and the difficulty in obtaining copy number variations in all 23 pairs of chromosomes. Multiple displacement amplification (MDA) has been reported to generate large quantity of products from small amount of templates. Here, we evaluated the fidelity of whole-genome amplification MDA from single or a few cells and determined the accuracy of chromosome copy number assessment on these MDA products using an Affymetrix 10K 2.0 SNP Mapping Array. An average coverage rate (86.2%) from single cells was obtained and the rates increased significantly when five or more cells were used as templates. Higher concordance for chromosome copy number from single cells could be achieved when the MDA amplified product was used as reference (93.1%) than when gDNA used as reference (82.8%). The present study indicates that satisfactory genome coverage can be obtained from single-cell MDA which may be used for studies where only a minute amount of genetic materials is available. Clinically, MDA coupled with SNP mapping array may provide a reliable and accurate method for chromosome copy number analysis and most likely for the detection of single-gene disorders as well.
- 1 January 2004
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 137 (1) , 18-23
Preimplantation genetic diagnosis for retinoblastoma: the first reported liveborn
- 1 January 2004
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 137 (1) , 18-23
Preimplantation genetic diagnosis for retinoblastoma: the first reported liveborn