LCLeok Poh Chua

Leok Poh Chua

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Leok Poh Chua has a total of 41 co-authors. Here are the top co-authors by number of shared publications:

  • Guoliang Song

    School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore

    5 shared publications
  • Tongming Zhou

    School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore

    5 shared publications
  • Tau Meng Lim

    School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore

    4 shared publications
  • Jun-Mei Zhang

    National Heart Centre Singapore, Singapore

    3 shared publications
  • Kang Shiu Ong

    School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore

    3 shared publications
  • S.C.M. Yu

    Thermal and Fluids Engineering Division, School of Mechanical and Production Engineering, Nanyang Technological University, Nanyang Avenue, Singapore 639798, Singapore

    3 shared publications

Latest Publications

  • Evaluation of Artificial Hearts

    by B. Y. Su, L. P. Chua

  • Near- and Far-Field Acoustic Measurements for Stepped Nozzles at Over- and Perfectly-Expanded Supersonic Jet Flow Conditions

    by Xiaofeng Wei, Leok Poh Chua, Zhenbo Lu, Haoxiang Desmond Lim, Raffaello Mariani, Yongdong Cui, T. H. New

    Detailed near- and far-field acoustic measurements were conducted for two circular stepped nozzles with 30 deg and 60 deg design inclinations at over- and perfectly-expanded supersonic jet flow conditions and compared to those for a circular nonstepped nozzle. Far-field acoustic results show that stepped nozzles play an insignificant role in altering noise emissions at perfectly expanded condition. At an over-expanded condition, however, the longer stepped nozzle produces significant noise reductions at the sideline and upstream quadrants, while the shorter stepped nozzle does not. Noise spectra analysis and Schlieren visualizations show that noise reduction can be primarily attributed to mitigations in the broadband shock-associated noise (BSAN), due to the ability of the longer stepped nozzle in suppressing shock strengths at downstream region. Near-field acoustic measurements reveal that the source region, as well as the intensity of turbulent and shock noises, are highly sensitive to the stepped nozzle configuration. Furthermore, BSAN seems to be eliminated by the longer stepped nozzle in near-field region due to the shock structure modifications.


  • A Novel Coronary Artery Bypass Graft Design of Sequential Anastomoses

    by Foad Kabinejadian, Leok Poh Chua, Dhanjoo N. Ghista, Meena Sankaranarayanan, Yong Seng Tan

    In this paper, the hemodynamics in a three-dimensional out-of-plane sequential bypass graft model is first investigated. Based on the advantageous flow characteristics observed within the side-to-side (STS) anastomosis in the sequential bypass graft simulation, a new CABG coupled-sequential anastomosis configuration is designed, entailing coupled STS and end-to-side (ETS) anastomotic components. In this new CABG design, the flow fields and distributions of various wall shear stress parameters within the STS and ETS anastomotic regions are studied, and compared to those of the conventional distal anastomosis, by means of computational fluid dynamics simulation of pulsatile Newtonian blood flow. Simulation results demonstrate that the new sequential anastomoses model provides: (i) a more uniform and smooth flow at the ETS anastomosis, without any stagnation point on the artery bed and vortex formation in the heel region of the ETS anastomosis within the coronary artery; (ii) a spare route for the blood flow to the coronary artery, to avoid re-operation in case of re-stenosis in either of the anastomoses; and (iii) improved distribution of hemodynamic parameters at the coronary artery bed and in the heel region of the ETS anastomosis, with more moderate shear stress indices. These advantages of the new design over the conventional ETS anastomosis are influenced by the occlusion ratio of the native coronary artery, and are most prominent when the proximal segment of the coronary artery is fully occluded. By varying the design parameters of the anastomotic angle and distance between the two anastomoses, the superior coupled STS–ETS anastomoses design is found to have the anastomotic angle of 30° and 30 mm distance between the two (STS and ETS) components.


  • Numerical Study of a Bio‐Centrifugal Blood Pump With Straight Impeller Blade Profiles

    by Guoliang Song, Leok Poh Chua, Tau Meng Lim

    Computational fluid dynamic simulations of the flow in the Kyoto‐NTN (Kyoto University, Kyoto, Japan) magnetically suspended centrifugal blood pump with a 16‐straight‐bladed impeller were performed in the present study. The flow in the pump was assumed as unsteady and turbulent, and blood was treated as a Newtonian fluid. At the impeller rotating speed of 2000 rpm and flow rate of 5 L/min, the pump produces a pressure head of 113.5 mm Hg according to the simulation. It was found that the double volute of the pump has caused symmetrical pressure distribution in the volute passages and subsequently caused symmetrical flow patterns in the blade channels. Due to the tangentially increasing pressure in the volute passages, the flow through the blade channels initially increases at the low‐pressure region and then decreases due to the increased pressure. The reverse flow and vortices have been identified in the impeller blade channels. The high shear stress of the flow in the pump mainly occurred at the inlet and outlet of the blade channels, the beginning of the volute passages and the regions around the tips of the cutwater and splitter plate. Higher shear stress is obtained when the tips of the cutwater and splitter plate are located at the impeller blade trailing edges than when they are located at the middle of the impeller blade channel. It was found that the blood damage index assessed based on the blood corpuscle path tracing of the present pump was about 0.94%, which has the same order of magnitude as those of the clinical centrifugal pumps reported in the literature.


  • Measurements by Laser Doppler Velocimetry in the Casing/Impeller Clearance Gap of a Biocentrifugal Ventricular Assist Device Model

    by Leok Poh Chua, Kang Shiu Ong, Guoliang Song, Wenfa Ji

    The velocity distributions in the clearance gap of the Kyoto-NTN biocentrifugal ventricular assist device model were measured by laser Doppler velocimetry (LDV) at three inlet flow conditions, namely operating, fully opened, and fully closed conditions. The results obtained have a similar trend as in the earlier measurements using air as medium and the hot-wire probe, a washout mechanism that is a segment of fluids in the gap situated from theta = 60 degrees to 220 degrees, has a larger radial velocity component flowing toward the eye of the pump, as compared to other regions in the gap where the tangential velocity component is dominant. It is essential to have a good washout for the leakage flow through the clearance gap between the stationary casing and the impeller of the pump so that the blood will not keep on circulating in the gap but is washed out to the eye in order to reduce the chances of being destroyed. Although the detailed velocity distributions are not the same, this should be due to the minor fabrication differences between two pump models. The current noninvasive LDV measurements should have a better representation of the actual flow field than the earlier studies due to the blood analog being used as the flow medium. Furthermore, as compared to the methods used in the earlier studies, there is basically no modification of the pump geometry in the present measurement.


  • Particle image velocimetry measurements of three proximal anastomosis models under a pulsatile flow condition

    by L P Chua, W-F Ji, C M Yu, T-M Zhou, Y S Tan

    This study was designed to examine the effects of the anastomotic angle on the flow and haemodynamic parameter distribution patterns of the proximal anastomoses, with emphasis on identifying site-specific haemodynamic features that could reasonably be expected to trigger the initiation and further development of anastomotic intimal hyperplasia. Particle image velocimetry measurements were carried out with three simplified glass proximal models under a physiological flow condition. The results revealed that the disturbed flow and the induced shear stress patterns including low recirculation flow, stagnation point, high wall shear stress, high temporal wall shear stress gradient, low time-averaged wall shear stress (TAWSS), and high oscillating shear index (OSI) occurred around the anastomotic joints and the flow field at proximal anastomosis was strongly affected by the anastomotic angle. Among the three models investigated, the 45° backward anastomosis is found to have a smaller low-recirculation-flow region along the graft inner wall, non-stationary stagnation, and separation points, a higher TAWSS and smaller high-OSI low-TAWSS and low-OSI high-TAWSS regions.


  • Numerical investigation and identification of susceptible sites of atherosclerotic lesion formation in a complete coronary artery bypass model

    by Jun-Mei Zhang, Leok Poh Chua, Dhanjoo N. Ghista, Simon Ching Man Yu, Yong Seng Tan

    As hemodynamics is widely believed to correlate with anastomotic stenosis in coronary bypass surgery, this paper investigates the flow characteristics and distributions of the hemodynamic parameters (HPs) in a coronary bypass model (which includes both proximal and distal anastomoses), under physiological flow conditions. Disturbed flows (flow separation/reattachment, vortical and secondary flows) as well as regions of high oscillatory shear index (OSI) with low wall shear stress (WSS), i.e., high-OSI-and-low-WSS and low-OSI-and-high-WSS were found in the proximal and distal anastomoses, especially at the toe and heel regions of distal anastomosis, which indicate highly suspected sites for the onset of the atherosclerotic lesions. The flow patterns found in the graft and distal anastomoses of our model at deceleration phases are different from those of the isolated distal anastomosis model. In addition, a huge significant difference in segmental averages of HPs was found between the distal and proximal anastomoses. These findings further suggest that intimal hyperplasia would be more prone to form in the distal anastomosis than in the proximal anastomosis, particularly along the suture line at the toe and heel of distal anastomosis.