Michael Beyer
Research Subjects
Michael Beyer has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Ulrich Krühne
Department of Chemical and Biochemical Engineering Technical University of Denmark Lyngby Denmark
2 shared publications - Birgitte Regenberg
Ecology and Evolution, Department of Biology, University of Copenhagen
1 shared publication - Jens Nielsen
BioInnovation Institute, Copenhagen, Denmark
1 shared publication - Lars H Pedersen
Department of Molecular Characterization, Biotechnological Institute, Kogle Allé 2, DK-2970 Hørsholm, Denmark
1 shared publication - Lars H. Pedersen
Bioneer A/S, Kogle Allé 2, 2970 Hørsholm, Denmark
1 shared publication Marcos Simón
Center for Microbiol Biotechnology, Technical University of Denmark, Lyngby, Denmark
1 shared publication
Latest Publications
- 11 November 2004
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 4 (6) , 654-657
Use of laminar flow patterning for miniaturised biochemical assays
Laminar flow in microfluidic chambers was used to construct low (one dimensional) density arrays suitable for miniaturized biochemical assays. By varying the ratio of flows of two guiding streams flanking a sample stream, precise focusing and positioning of the latter was achieved, and reactive species carried in the sample stream were deposited on functionalized chip surfaces as discrete 50 µm wide lanes. Using different model systems we have confirmed the method's suitability for qualitative screening and quantification tasks in receptor–ligand assays, recording biotin–streptavidin interactions, DNA-hybridization and DNA-triplex formation. The system is simple, fast, reproducible, flexible, and has small sample requirements.
- 11 November 2004
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 4 (6) , 654-657
Use of laminar flow patterning for miniaturised biochemical assays
Laminar flow in microfluidic chambers was used to construct low (one dimensional) density arrays suitable for miniaturized biochemical assays. By varying the ratio of flows of two guiding streams flanking a sample stream, precise focusing and positioning of the latter was achieved, and reactive species carried in the sample stream were deposited on functionalized chip surfaces as discrete 50 µm wide lanes. Using different model systems we have confirmed the method's suitability for qualitative screening and quantification tasks in receptor–ligand assays, recording biotin–streptavidin interactions, DNA-hybridization and DNA-triplex formation. The system is simple, fast, reproducible, flexible, and has small sample requirements.
- Open Access
- 23 July 2003
- Published by Springer Nature in BMC Biotechnology
- Vol. 3 (1) , 10
Hydrodynamic guiding for addressing subsets of immobilized cells and molecules in microfluidic systems
The interest in microfluidics and surface patterning is increasing as the use of these technologies in diverse biomedical applications is substantiated. Controlled molecular and cellular surface patterning is a costly and time-consuming process. Methods for keeping multiple separate experimental conditions on a patterned area are, therefore, needed to amplify the amount of biological information that can be retrieved from a patterned surface area. We describe, in three examples of biomedical applications, how this can be achieved in an open microfluidic system, by hydrodynamically guiding sample fluid over biological molecules and living cells immobilized on a surface. A microfluidic format of a standard assay for cell-membrane integrity showed a fast and dose-dependent toxicity of saponin on mammalian cells. A model of the interactions of human mononuclear leukocytes and endothelial cells was established. By contrast to static adhesion assays, cell-cell adhesion in this dynamic model depended on cytokine-mediated activation of both endothelial and blood cells. The microfluidic system allowed the use of unprocessed blood as sample material, and a specific and fast immunoassay for measuring the concentration of C-reactive protein in whole blood was demonstrated. The use of hydrodynamic guiding made multiple and dynamic experimental conditions on a small surface area possible. The ability to change the direction of flow and produce two-dimensional grids can increase the number of reactions per surface area even further. The described microfluidic system is widely applicable, and can take advantage of surfaces produced by current and future techniques for patterning in the micro- and nanometer scale.
- 23 July 2003
- Published by Springer Nature in BMC Biotechnology
- Vol. 3 (1) , 10
Open AccessHydrodynamic guiding for addressing subsets of immobilized cells and molecules in microfluidic systems
The interest in microfluidics and surface patterning is increasing as the use of these technologies in diverse biomedical applications is substantiated. Controlled molecular and cellular surface patterning is a costly and time-consuming process. Methods for keeping multiple separate experimental conditions on a patterned area are, therefore, needed to amplify the amount of biological information that can be retrieved from a patterned surface area. We describe, in three examples of biomedical applications, how this can be achieved in an open microfluidic system, by hydrodynamically guiding sample fluid over biological molecules and living cells immobilized on a surface. A microfluidic format of a standard assay for cell-membrane integrity showed a fast and dose-dependent toxicity of saponin on mammalian cells. A model of the interactions of human mononuclear leukocytes and endothelial cells was established. By contrast to static adhesion assays, cell-cell adhesion in this dynamic model depended on cytokine-mediated activation of both endothelial and blood cells. The microfluidic system allowed the use of unprocessed blood as sample material, and a specific and fast immunoassay for measuring the concentration of C-reactive protein in whole blood was demonstrated. The use of hydrodynamic guiding made multiple and dynamic experimental conditions on a small surface area possible. The ability to change the direction of flow and produce two-dimensional grids can increase the number of reactions per surface area even further. The described microfluidic system is widely applicable, and can take advantage of surfaces produced by current and future techniques for patterning in the micro- and nanometer scale.