ADArnaldo Dubin

Arnaldo Dubin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Arnaldo Dubin has a total of 23 co-authors. Here are the top co-authors by number of shared publications:

  • Elisa Estenssoro

    Servicio de Terapia Intensiva, Hospital Interzonal General de Agudos General San Martín, 1900, la Plata, Argentina

    6 shared publications
  • Fernando Pálizas

    Medical Director, Servicio de Terapia Intensiva, Clínica Bazterrica de Buenos Aires, Argentina

    4 shared publications
  • Héctor Canales

    Staff physician, Servicio de Terapia Intensiva, Hospital San Martín de La Plata, Argentina

    4 shared publications
  • Julio Badie

    Research Fellow, Cátedra de Farmacología, Facultad de Ciencias Médicas, Universidad Nacional de La Plata, Argentina

    4 shared publications
  • Gastón Murias

    Cátedra de Farmacología Aplicada, Facultad de Ciencias Médicas, Universidad Nacional de La Plata, La Plata, Argentina

    3 shared publications
  • Marcelo Barán

    Medical Director, Unidad de Transplante Renal, CRAI Sur, CUCAIBA, Argentina

    3 shared publications

Latest Publications

  • Impact of positive end-expiratory pressure on the definition of acute respiratory distress syndrome

    by Elisa Estenssoro, Arnaldo Dubin, Enrique Laffaire, Héctor S Canales, Gabriela Sáenz, Miriam Moseinco, Pierina Bachetti

    We examined whether PEEP during the first hours of ARDS can induce such a change in oxygenation that could mask fulfillment of the AECC criteria of a PaO2/FIO2 ≤ 200 essential for ARDS diagnosis.


    • 31 March 2003
      • Vol. 7  (3) , 245

    Intramucosal–arterial PCO2 gap does reflect tissue dysoxia – authors' response

    by Arnaldo Dubin, Elisa Estenssoro

  • Open Access

    Intramucosal–arterial PCO 2 gap fails to reflect intestinal dysoxia in hypoxic hypoxia

    by Arnaldo Dubin, Gastón Murias, Elisa Estenssoro, Héctor Canales, Julio Badie, Mario Pozo, Juan P Sottile, Marcelo Barán, Fernando Pálizas, Mercedes Laporte

    Introduction: An elevation in intramucosal–arterial PCO2 gradient (ΔPCO2) could be determined either by tissue hypoxia or by reduced blood flow. Our hypothesis was that in hypoxic hypoxia with preserved blood flow, ΔPCO2 should not be altered. Methods: In 17 anesthetized and mechanically ventilated sheep, oxygen delivery was reduced by decreasing flow (ischemic hypoxia, IH) or arterial oxygen saturation (hypoxic hypoxia, HH), or no intervention was made (sham). In the IH group (n = 6), blood flow was lowered by stepwise hemorrhage; in the HH group (n = 6), hydrochloric acid was instilled intratracheally. We measured cardiac output, superior mesenteric blood flow, gases, hemoglobin, and oxygen saturations in arterial blood, mixed venous blood, and mesenteric venous blood, and ileal intramucosal PCO2 by tonometry. Systemic and intestinal oxygen transport and consumption were calculated, as was ΔPCO2. After basal measurements, measurements were repeated at 30, 60, and 90 minutes. Results: Both progressive bleeding and hydrochloric acid aspiration provoked critical reductions in systemic and intestinal oxygen delivery and consumption. No changes occurred in the sham group. ΔPCO2 increased in the IH group (12 ± 10 [mean ± SD] versus 40 ± 13 mmHg; P < 0.001), but remained unchanged in HH and in the sham group (13 ± 6 versus 10 ± 13 mmHg and 8 ± 5 versus 9 ± 6 mmHg; not significant). Discussion: In this experimental model of hypoxic hypoxia with preserved blood flow, ΔPCO2 was not modified during dependence of oxygen uptake on oxygen transport. These results suggest that ΔPCO2 might be determined primarily by blood flow.


  • Effects of hemorrhage on gastrointestinal oxygenation

    by Arnaldo Dubin, Elisa Estenssoro, Gastón Murias, Héctor Canales, Pablo Sottile, Julio Badie, Marcelo Barán, Fernando Pálizas, Mercedes Laporte, Mariana Rivas Díaz

    Objectives: (1) To demonstrate that metabolic parameters are better indicators of tissue hypoxia than regional and whole oxygen consumption (VO2). (2) To compare intramucosal pH (pHi) in different gastrointestinal segments. Design: Prospective, interventional study. Setting: Research laboratory at a university center. Subjects: Fourteen anesthetized, mechanically ventilated dogs. Interventions: Twenty milliliters per kilogram bleeding. Measurements and main results: We placed pulmonary, aortic and mesenteric venous catheters, and an electromagnetic flow probe in the superior mesenteric artery, and gastric, jejunal and ileal tonometers to measure flows, arterial and venous blood gases and lactate, and intramucosal PCO2. We calculated systemic and intestinal oxygen transport (DO2) and consumption (VO2), pHi and arterial minus intramucosal PCO2 (ΔPCO2). Then, we bled the dogs and repeated the measurements after 30 min. Systemic and intestinal DO2 fell (26.0±7.3 versus 8.9±2.6 and 71.9±17.3 versus 24.6±9.6 ml/min per kg, respectively, p2 remained unchanged (5.5±1.3 versus 5.4±1.3 and 15.7±5.0 versus 14.9±5.3 ml/min per kg, respectively). Gastric, jejunal and ileal pHi (7.13±0.11 versus 6.96±0.17, 7.18±0.06 versus 6.97±0.15, 7.12±0.11 versus 6.94±0.14, p2 (21±13 versus 35±23, 15±5 versus 33±16, 23±17 versus 38±20, ppConclusions: During hemorrhage, systemic and intestinal VO2 remained stable. However, hyperlactatemia and intramucosal acidosis evidenced anaerobic metabolism. pHi changes paralleled in the three intestinal segments.


  • End-tidal CO2 pressure determinants during hemorrhagic shock

    by Arnaldo Dubin, Gastón Murias, Elisa Estenssoro, Héctor Canales, Pablo Sottile, Julio Badie, Marcelo Barán, Silvio Rossi, Mercedes Laporte, Fernando Pálizas, et al.

    Objectives: To examine the relationship between end-tidal CO2 (PETCO2) and its physiological determinants, pulmonary blood flow (cardiac output, CO) and CO2 production (VCO2), in a model of hemorrhagic shock during fixed minute ventilation. Design and setting: Prospective, observational study in a research laboratory at a university center. Subjects and interventions: Six anesthetized, intubated, and mechanically ventilated mongrel dogs. Progressive stepwise bleeding. Measurements and results: We continuously measured PETCO2 with a capnograph, pulmonary artery blood flow with an electromagnetic flow probe, arterial oxygen saturation (SaO2) with a fiberoptic catheter, and oxygen consumption (VO2) and VCO2 by expired gases analysis. Oxygen delivery (DO2) was continuously calculated from pulmonary blood flow and SaO2. We studied the correlation of PETCO2 with CO and VCO2 in each individual experiment. We also calculated the critical point in the relationships PETCO2/DO2 and VO2/DO2 by the polynomial method. As expected, PETCO2 was correlated with CO. The best fit was logarithmic in all experiments (median r 2=0.90), showing that PETCO2 decrease is greater in lowest flow states. PETCO2 was correlated with VCO2, but the best fit was linear (median r 2=0.77). Critical DO2 for PETCO2 and VO2 was 8.0±3.3 and 6.3±2.5 ml.min–1.kg–1, respectively (NS). Conclusions: Our data reconfirm the relationship between PETCO2 and CO during hemorrhagic shock. The relatively greater decrease in PETCO2 at lowest CO levels could represent diminished CO2 production during the period of VO2 supply dependency.


  • Open Access

    Lack of agreement between tonometric and gastric juice partial carbon dioxide tension

    by Arnaldo Dubin, Julio Badie, Sofía Fernandez, Elisa Estenssoro, Héctor Canales, Guillermo Bordoli, Fernando Pálizas

    Our goal was to compare measurement of tonometered saline and gastric juice partial carbon dioxide tension (PCO2). In this prospective observational study, 112 pairs of measurements were simultaneously obtained under various hemodynamic conditions, in 15 critical care patients. Linear regression analysis showed a significant correlation between the two methods of measuring PCO2 (r2 = 0.43; P < 0.0001). However, gastric juice PCO2 was systematically higher (mean difference 51 mmHg). The 95% limits of agreement were 315 mmHg and the dispersion increased as the values of PCO2 increased. Tonometric and gastric juice PCO2 cannot be used interchangeably. Gastric juice PCO2 measurement should be interpreted with caution.