MAMani Ashouri

Mani Ashouri

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mani Ashouri has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Modal online differential fault detection and localisation scheme for VSC‐MTDC cable transmission

    by Mani Ashouri, Filipe Faria da Silva, Claus Leth Bak, Aliakbar Abdoos, Seyed Mehdi Hosseini

    This study proposes a modal online differential fault detection and localization (MODF) scheme for VSC‐MTDC cable transmission. Modal theory is used to remove the coupling between layers of two‐core extruded high‐voltage direct current cable. As a result, the decoupled modes are determined and the modal matrix resulted. In high frequencies, the modes have different velocities, which result in a time difference between modal initial peaks. This time delay is used to design modal fault detection and localization scheme, which can work in a variety of strategies like pilot or non‐communicated protection systems, one‐sided or two‐sided relaying, and single‐zone or double‐zone relay settings. Novel modal time–distance characteristics are introduced for adjusting the zone setting of relays in the MODF scheme. Multiple faults are applied to the CIGRE VSC‐MTDC model in the real‐time digital simulator with a Beckhoff CX5130 controller in the hardware‐in‐the‐loop setup for testing the proposed MODF scheme. The advantages and weak points of each strategy are analyzed and compared for the modelled faults. Hilbert–Huang transform is used for the accurate detection of modal initial peaks. It is shown that the method gives accurate and selective results for a wide range of VSC‐MTDC configurations.


  • On the Application of Modal Transient Analysis for Online Fault Localization in HVDC Cable Bundles

    by Mani Ashouri, Filipe Faria da Silva, Claus Leth Bak

    This paper presents the modal analysis of different HVDC cable bundles. Using modal theory, specific transformation matrices are presented, and the modal equivalent circuits are illustrated. The behavior of the resulting modes is studied in a wide frequency range, the impact of different cable parameters and burial configurations on the modal characteristics are analyzed. A concept for online fault localization in HVDC cable transmission based on the difference between the modal velocities and consequently the arrival times of the modal traveling wave (TW) initial peaks is presented. In this method, modal voltages and currents are used instead of direct measurements and the proposed concept uses one-sided measurement without needing to detect the second TW reflections. Multiple faults are applied to CIGRE HVDC models in PSCAD/EMTDC and the modal analysis is obtained in MATLAB. The impact of different sampling frequencies, fault resistance, fault location and different grounding schemes on the proposed modal fault location principle is analyzed. The theoretical results show the accuracy of the proposed modal fault localization concept for different HVDC cable bundles.


  • Online Fault Location in Monopolar LCC-HVDC links With Metallic Return Using Modal Transient Data

    by Mani Ashouri, Filipe Faria da Silva, Claus Leth Bak

    This paper proposes an online fault localization technique for line commutated converter high voltage direct current (LCC-HVDC) transmission links, which use single core monopolar cables with metallic return. The conducting layers of the cables have mutual off-diagonal elements in the longitudinal impedance matrix. Thereupon, in case of faults in DC transmission section due to the coupling between conducting layers, using the direct measurements for localizing the fault results in a noticeable amount of error. In this paper, based on the modal theory, the longitudinal matrix of HVDC cable bundle is diag-onalized into the decoupled modal matrix. Each of the resulted modes has different attenuation, velocities, and characteristic impedances. According to this velocity difference, an online one-sided modal fault location algorithm is presented. The proposed method gives more accurate results than common methods that use direct traveling wave data for fault localization. Discrete Wavelet Transform (DWT) is used for detecting modal initial peaks. CIGRE LCC-HVDC link is modeled in PSCAD/EMTDC and further fault location algorithm is designed in MATLAB. The comparison between obtained results and techniques based on direct measurement proves the accuracy and robustness of the proposed modal fault location algorithm.


  • Open Access

    A Harmonic Based Pilot Protection Scheme for VSC-MTDC Grids with PWM Converters

    by Mani Ashouri, Filipe Faria da Silva, Claus Leth Bak

    This paper presents a selective harmonic-based pilot protection scheme for detecting faults happened in the DC transmission section of VSC-MTDC grids with pulse width modulation (PWM) voltage source converters (VSCs). When a DC fault occurs in VSC-MTDC grids with PWM converters, first carrier frequency harmonic (FCFH) currents will be generated by all VSCs through the grid. FCFH currents have different flowing directions depending on the characteristics and the location of the fault. According to the characteristics of the existing FCFH in the fault currents, a selective pilot protection algorithm is designed for VSC-MTDC grids. Considering the internal and external DC transmission faults for specific zones, and the circulating flow of FCFH current in the DC link capacitors, the relays cannot detect FCFH currents for external faults, while for the internal faults, FCFH currents are clearly detected. To design the selective protection algorithm, Hilbert-Huang transform (HHT) is used to detect the instantaneous frequency and the instantaneous amplitude of the high frequency intrinsic mode function (IMF)s, which are extracted from the fault current waves. Multiple faults with different characteristics are applied to CIGRE DCS-2 VSC-MTDC grid with two-level and three-level VSCs modeled in PSCAD, and the HHT-based selective protection scheme is designed in MATLAB. According to the results, the proposed algorithm can truly discriminate between internal and external faults.


  • Open Access

    Application of short‐time Fourier transform for harmonic‐based protection of meshed VSC‐MTDC grids

    by Mani Ashouri, Filipe F.D. Silva, Claus L. Bak

    This work studies the application of short‐time Fourier transform (STFT) to extract current harmonics of various fault types to design a protection method for meshed multi‐terminal voltage source converter‐high‐voltage direct current (VSC‐HVDC‐MTDC) grids. The frequency spectrum of fault current harmonics is used to detect internal and external faults, the faulty pole and fault type. The method does not need the implementation of series inductance on the sides of the DC lines and it is also effective for lines combining overhead lines and cables. The window function and hop size play the primary role in STFT, which are investigated in a sensitivity analysis. A modified version of CIGRE meshed DC grid system is simulated in PSCAD in order to show the robustness of the method, and further signal processing analysis is done in MATLAB. The results show the accurate detection and discrimination between faulty sections using the proposed harmonic‐based method and how important the STFT parameters are in order to have a robust protection algorithm.


  • Protection of Multi-Terminal VSC-HVDC Grids Based on the Response of the First Carrier Frequency Harmonic Current

    by Mani Ashouri, Hesam Khazraj, Filipe Faria da Silva, Claus Leth Bak

    Protection of multi-terminal Voltage Source Converter based High Voltage Direct Current (VSC-MTDC) grids is a major challenge for future practical DC transmission technology. According to the harmonic-based protection studies, the response of first carrier frequency harmonic (FCFH) current in Pulse Width Modulation (PWM)-based VSC-HVDC can be used to discriminate external AC faults in point to point VSC-HVDC systems. However, the application of FCFH current for a selective fault detection system in VSC-MTDC grids is not studied yet. This research investigates FCFH current existed in converter DC link measured data, to detect the faulty section in VSC-MTDC system, when the system face faults with variations in location and resistance. A radial VSC-MTDC system with 2-level PWM VSC converters is simulated in PSCAD and MATLAB is used to extract FCFH current based on short-time Fourier transform. Based on the relay locations, the results show the feasibility of the protection algorithm, in discriminating between internal and faults for each zone.


  • An Adaptive Algorithm for Fault Identification in Transmission Lines by Short-Time Fourier Transform Function

    by Hesam Khazraj, Mani Ashouri, Athanasios Stamatopoulos, F. Faria da Silva, Claus Leth Bak, Babak Yousefi Khangah

    Transmission lines are protected by distance relays as main protection and overcurrent relays as backup protection. Both of distance relays and overcurrent relays have mal-operation during high Impedance faults, faults in the week in-feed systems and faults occurred during power swing. Fluctuations in voltage and current during power swing cause fluctuations in measured impedance by distance relay. In some measured impedance moves to protected zone and causes mal-operation. So, distance relay is blocked duration of a power swing. In cases that fault occurs during a power swing, the relay must detect fault inception. In this paper, a new algorithm for fault detection in cases with low fault current and fault detection during power swing is presented. Diagnostic criteria in this algorithm are the calculation of the spectral energy of current signal by the Adaptive Short-Time Fourier transform (ASTFT). Fault currents consist of a considerable amount of high-frequency components which they do not exist the in-line current during overload or power swing. The presented method is based on cooperation between existing fault detection methods and a fault detection using ASTST. Different conditions are Simulated in this paper in the software / EMTDC PSCAD and MATLAB to verify of correct performance of the proposed algorithm.


  • Transfer Matrix-Based Differential Protection of Transmission Lines

    by Hesam Khazraj, Mani Ashouri, Athanasios Stamatopoulos, F. Faria da Silva, Claus Leth Bak

    In this paper, a new differential integrated line protection scheme is presented. A central computer or relay in a control center provides protection for multiple transmission lines. The transmission line may be modeled by a transfer matrix similar to a dipole circuit, which relates the local bus current and voltage signals to the remote units. However, the transfer matrix of the line is not applicable when a fault occurs on the associated line. This concept is applied in the proposed method for fault detection. Simulation results verify that the novel integrated protection scheme, using the proposed method, operates correctly for the various test cases. The proposed method resolves several shortcomings of the existing transmission line protection schemes. It works accurately for high-resistance faults and has the feature of unit protection in identifying the faulted line. Using one central relay significantly decreases the overall cost of protection equipment in the system. The proposed integrated protection scheme detects the faults approximately one cycle after the fault occurrence, which is very fast among other proposed methods.