Pedro T. Martín de la Vega
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Pedro T. Martín de la Vega has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Miguel Ángel Jaramillo-Morán
Escuela de Ingenierías Industriales, Universidad de Extremadura, Avenida de Elvas s/n, 06006 Badajoz, Spain
3 shared publications E. Martínez de Salazar
1 shared publicationJ. Cros
1 shared publication- M. I. Fernández-Fernández
Department of Electrical Engineering, Electronics & Automation, University of Extremadura, Avda.Elvas s/n, 06006 Badajoz, Spain
1 shared publication M.A. Jaramillo
1 shared publication
Latest Publications
- Open Access
Pollution and Sustainability Indices for Small and Medium Wastewater Treatment Plants in the Southwest of Spain
Two indices have been defined in this work to measure the pollution load that a Wastewater Treatment Plant (WWTP) receives and the efficiency of the process it carries out from the overall perspective of pollution removal and energy efficiency. The aim is to provide two performance parameters which could be used to characterize both the working conditions of a WWTP and how well it treats the pollution it receives. In this way, they may be used to compare the behavior of different plants in a certain geographical area. Forty-five WWTPs in the Southwest of Spain were studied to find out the most significant information that is to be used to identify and define both indices. Seven of the variables recorded were used to define each one. Their values were calculated for the whole set of plants studied. The results showed that most of the plants received a low pollution load. Only six of them suffered from a high pollution load, probably because of farms and food industries located in their surroundings. Only three plants showed a poor efficiency, while 23 of them presented a very good one.
Open AccessPollution and Sustainability Indices for Small and Medium Wastewater Treatment Plants in the Southwest of Spain
Two indices have been defined in this work to measure the pollution load that a Wastewater Treatment Plant (WWTP) receives and the efficiency of the process it carries out from the overall perspective of pollution removal and energy efficiency. The aim is to provide two performance parameters which could be used to characterize both the working conditions of a WWTP and how well it treats the pollution it receives. In this way, they may be used to compare the behavior of different plants in a certain geographical area. Forty-five WWTPs in the Southwest of Spain were studied to find out the most significant information that is to be used to identify and define both indices. Seven of the variables recorded were used to define each one. Their values were calculated for the whole set of plants studied. The results showed that most of the plants received a low pollution load. Only six of them suffered from a high pollution load, probably because of farms and food industries located in their surroundings. Only three plants showed a poor efficiency, while 23 of them presented a very good one.
- Open Access
Multilevel Adaptive Control of Alternating Aeration Cycles in Wastewater Treatment to Improve Nitrogen and Phosphorous Removal and to Obtain Energy Saving
This work presents an adaptive control of the process of alternating aeration/non-aeration cycles for wastewater treatment. It is aimed at improving nitrogen and phosphorous removal efficiency and reducing energy consumption. It comprises two control levels. The first decides when to switch on and off aeration by comparing the Dissolved Oxygen (DO) and the Oxidation Reduction Potential (ORP) with two activation thresholds. The second, a supervisory control, continuously adapt their values by analyzing the working conditions of the reactor (organic matter and ammonium loads). These working conditions are described by four parameters obtained from the DO and ORP curves: Oxygen Uptake Rate (OUR), Oxygen Rise Average Slope (ORAS), ORParrow and Nitrate and Oxygen Uptake Rate (NOUR). It also adjusts the aeration system power to adapt it to those conditions. This adaptive control has been implemented in a laboratory scale prototype and its performance compared with that provided by another control with fixed thresholds and aeration power implemented in a similar prototype. The adaptive control clearly outperforms that without adaptation in nitrogen and phosphorous removal efficiency and requires lower energy consumption. Similar efficiencies were obtained for organic matter removal (higher than 90% in both cases).
Open AccessMultilevel Adaptive Control of Alternating Aeration Cycles in Wastewater Treatment to Improve Nitrogen and Phosphorous Removal and to Obtain Energy Saving
This work presents an adaptive control of the process of alternating aeration/non-aeration cycles for wastewater treatment. It is aimed at improving nitrogen and phosphorous removal efficiency and reducing energy consumption. It comprises two control levels. The first decides when to switch on and off aeration by comparing the Dissolved Oxygen (DO) and the Oxidation Reduction Potential (ORP) with two activation thresholds. The second, a supervisory control, continuously adapt their values by analyzing the working conditions of the reactor (organic matter and ammonium loads). These working conditions are described by four parameters obtained from the DO and ORP curves: Oxygen Uptake Rate (OUR), Oxygen Rise Average Slope (ORAS), ORParrow and Nitrate and Oxygen Uptake Rate (NOUR). It also adjusts the aeration system power to adapt it to those conditions. This adaptive control has been implemented in a laboratory scale prototype and its performance compared with that provided by another control with fixed thresholds and aeration power implemented in a similar prototype. The adaptive control clearly outperforms that without adaptation in nitrogen and phosphorous removal efficiency and requires lower energy consumption. Similar efficiencies were obtained for organic matter removal (higher than 90% in both cases).
- Open Access
Obtaining Key Parameters and Working Conditions of Wastewater Biological Nutrient Removal by Means of Artificial Intelligence Tools
The oxidation-reduction potential (ORP) and the dissolved oxygen (DO) have been monitored in a municipal wastewater treatment plant (WWTP). Three thousand two hundred aeration–non-aeration cycles were recorded. They were analyzed by defining 16 parameters to characterize each one of them. The vectors so obtained were treated with the box-plot tool to reject those with outliers (abnormally high or low values). The remaining data were processed by a neural network (self-organizing map: SOM) in order to classify them into classes and to obtain relations between parameters to identify those more representative of the system dynamics. They were: the oxygen uptake rate (OUR), the oxygen rise average slope (ORAS), and the oxidation-reduction potential “arrow” (ORParrow, the maximum distance between the ORP curve and its linearization). Finally, the classes obtained from SOM were grouped into four macro-classes by means of the K-means algorithm in order to define four operation states related to seasonal and load characteristics, which may be taken into account, along with the key parameters, in the WWTP management with the aim of improving the nutrient removal performance by adapting their controllers to seasonal and load variations.
Open AccessObtaining Key Parameters and Working Conditions of Wastewater Biological Nutrient Removal by Means of Artificial Intelligence Tools
The oxidation-reduction potential (ORP) and the dissolved oxygen (DO) have been monitored in a municipal wastewater treatment plant (WWTP). Three thousand two hundred aeration–non-aeration cycles were recorded. They were analyzed by defining 16 parameters to characterize each one of them. The vectors so obtained were treated with the box-plot tool to reject those with outliers (abnormally high or low values). The remaining data were processed by a neural network (self-organizing map: SOM) in order to classify them into classes and to obtain relations between parameters to identify those more representative of the system dynamics. They were: the oxygen uptake rate (OUR), the oxygen rise average slope (ORAS), and the oxidation-reduction potential “arrow” (ORParrow, the maximum distance between the ORP curve and its linearization). Finally, the classes obtained from SOM were grouped into four macro-classes by means of the K-means algorithm in order to define four operation states related to seasonal and load characteristics, which may be taken into account, along with the key parameters, in the WWTP management with the aim of improving the nutrient removal performance by adapting their controllers to seasonal and load variations.
- 1 June 2012
- Published by Elsevier in Bioresource Technology
- Vol. 114, 160-167
New contributions to the ORP & DO time profile characterization to improve biological nutrient removal
- 1 June 2012
- Published by Elsevier in Bioresource Technology
- Vol. 114, 160-167
New contributions to the ORP & DO time profile characterization to improve biological nutrient removal