Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hyosung Kim has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Voltage-Power Area for Arc-safe Operation of Electric Contacts in Low Voltage DC systems

    by Yong-Jung Kim, Hyosung Kim

    In AC power systems, the load current naturally reaches zero every half cycle, which results in a short-term spark that lasts less than a quarter cycle after the switch has been turned off or the plug has been removed from the socket. However, in DC power systems, the load current flows continuously without zero crossings, which causes the breaking arc to be prolonged and to develop easily into plasma, resulting in a high risk of arc accidents. Therefore, to ensure safety against breaking arcs in DC power systems, protective regulations must be established, and the physical properties of arc generation and extinction in DC power systems must be examined. This study aims to explore the experimental characteristics of breaking arcs in low-voltage DC systems that occur in normal brass electrodes, which are the main components of residential contact-type wall-mounted switches and socket-outlet plugs. This study analyzes the characteristics of breaking arcs between brass electrodes and presents a safe operation area for the arcs that is defined by the supply voltage and load power level. This study will enable nonexperts to use conventional brass electrode-based wall-mounted switches and socket-outlet plugs safely.

  • Open Access

    Aging Characteristics of Contact Electrodes of Low Voltage DC Switches

    by Hyosung Kim

    With the present state of the direct current (DC) distribution market, securing the safety of the DC distribution system is emerging as a major issue. Like AC distribution systems, DC switches and circuit breakers are one of the main means to ensure safety. However, in the DC system, since there is no current zero point in the load current, the phenomenon occurring when the circuit is cut off is different from that of the AC system, so technical research is required to cope with this. In this study, the aging characteristics of the contact electrode of a 400 V class low voltage DC (LVDC) switch is studied for the development of wall-mount switches or circuit breakers for residential houses. As an arc extinguishing method to break DC load current, a prototype experimental circuit breaker that uses a magnetic extinguishing method that is effective for blocking low voltage low power DC is invented, and an automated experiment system is established. The DC switch test repeats the operation of turning it on and off 13,000 times, and continuously evaluates the performance of the electric contacts by calculating the voltage drop between the electrode contacts and the corresponding Ohmic resistance value when conducting every 500 times. This paper tests six contact materials to compare the aging characteristics of them by evaluating contact resistance during the test period. AW18-Cu composite material showed the most stable and excellent contact performance for LVDC switches during the entire test operation period.


  • Open Access

    Modeling and Estimation of Break Arc Extinction Distance in Low Voltage DC Systems

    by Yong-Jung Kim, Hyo-Sung Kim

    Recently, as DC power generation and DC loads such as renewable energy and EVs increase, the need for a low-voltage direct current (LVDC) distribution system has gradually emerged. The DC system has various advantages, such as system stability, transmission efficiency, and connectivity to renewable power generation compared to AC distribution systems. One of the important technical issues for commercialization of DC distribution system is safety. Since the DC system does not have a current zero point, unlike the AC system, a breaking arc accompanied by a high-temperature plasma is easily generated when the circuit is cut off. The arc can cause fire accidents that threaten people and facilities. In order to prevent customers and facilities from the accidents caused by the arc in the DC system, a study on the characteristics of the DC breaking arc is necessary. An important factor of characteristics for the DC breaking arc fault is an arc extinction distance at which the DC breaking arc is completely extinguished. There are two major behaviors in DC breaking arc; one is active behavior where the arc voltage is inversely related with the arc current for a given gap distance, the other is passive behavior where the arc voltage is negatively proportional to the arc current according to Kirchhoff’s voltage rule. This paper combines the two arc characteristics together to establish a DC breaking arc model, and proposes a method to estimate the arc extinction distance. Experiment results verify the method under various power and load conditions.


  • Open Access

    Capacitor Commutation Method for MVDC Hybrid Circuit Breakers

    by Hyosung Kim

    The medium voltage DC (MVDC) type system can connect multiple terminals to a common MVDC bus, so it is possible to connect several renewable DC power sources to the common MVDC bus, but a DC circuit breaker is needed to isolate short circuit accidents that may occur in the MVDC bus. For this purpose, the concept of a hybrid DC circuit breaker that takes advantage of a low conduction loss contact type switch and an arcless-breaking semiconductor switch has been proposed. During break the hybrid switch, a dedicated current commutation device is required to temporarily bypass the load current flowing through the main switch into a semiconductor switch branch. Existing current commutation methods include a proactive method and a reverse current injection method by a LC (Inductor-capacitor) resonant circuit. This paper proposes a power circuit of a new MVDC hybrid circuit breaker using a low withstanding voltage capacitor branch for commutation and a sequence controller according to it, and verifies its operation through an experiment.


  • Open Access

    Gate Drive Controller for Low Voltage DC Hybrid Circuit Breaker

    by Hyosung Kim

    With the advent of direct current (DC) loads such as LED lighting, IT equipment, electric vehicles, and DC powers generated from renewable energy sources, low voltage DC (LVDC) distribution system is becoming a hot issue. One of the hurdles in the LVDC distribution system is arc flash at the contact points that occurs during the circuit is opening. Unlike alternating current, direct current has no zero points and sustains constantly. Therefore, there is a risk of electric fire due to continuous generating arcs when the load current is interrupted with an existing electrical contact type circuit breaker. Recently, the concept of a hybrid circuit breaker that takes advantage of traditional electrical contact type switch and the arcless semiconductor switch has been proposed, but how to cooperatively operate the two switches has become an issue. This paper analyzes the principle of a hybrid circuit breaker for blocking LVDC current and proposes a gate drive controller for it. Through 400V class LVDC cutoff test, the operation of the proposed hybrid circuit breaker is verified and the characteristics are analyzed.


  • Modeling for Series Arc of DC Circuit Breaker

    by Yong-Jung Kim, Hyosung Kim

    In electric distribution systems, a series arc occurs when a load and a power source are disconnected from a connector such as a circuit breaker, a socket-plug or a coupler. In DC systems, the arc is not extinguished unless the arc current decreases to zero. Sustaining plasma arc current can cause huge fire disasters. To cope with the arc faults in DC systems, the characteristics of the arc should be analyzed. However, a clear analysis method has not been suggested. This paper analyzes characteristics of a series-breaking arc in a DC circuit breaker in three operation phases; initiation, sustenance, and extinguishment. Based on the three operation characteristics, a series-breaking arc model is proposed and evaluated through experiment.


  • Open Access

    Arc Voltage and Current Characteristics in Low-Voltage Direct Current

    by Wooho Kim, Yong-Jung Kim, Hyosung Kim

    Recently, Low-Voltage DC (direct current) distribution systems have received high lights according to the expansion of DC generations and DC loads such as photovoltaics (PV) generations, electric vehicles (EVs), light emitting diodes (LEDs), computers, DC homes, etc. Low-Voltage DC distribution systems have optimistic perspectives since DC has various good aspects compared to alternating current (AC). However, ensuring safety of human and electric facility in Low-Voltage DC is not easy because of arc generation and difficulty of arc-extinguishing. This paper constructs a low-voltage DC circuit and studies the arc interruption that occurs when separating electrodes from where load currents flow. Also, arc extinguishers are experimented upon and analysed in various levels of source voltage and load currents conditions. Voltage and current characteristics for arc interruption are identified based on experimental results, and we establish the electric generation for arc interruption. Further, the voltage–current characteristics and the correlation of arc during arc duration time arc are verified, and the voltage–current equation and DC arc resistance model for the breaking arc are developed.


  • Open Access

    Luminescent properties of Eu3+-activated Gd2ZnTiO6 double perovskite red-emitting phosphors for white light-emitting diodes and field emission displays

    by Soo Hyun Lee, Youngjin Cha, Hyosung Kim, Seungmoo Lee, Jae Su Yu

    We synthesized a series of double perovskite Eu3+-activated Gd2ZnTiO6 red-emitting phosphors by a solid-state reaction method and analyzed their morphology, crystallinity, luminescent properties, and thermal stability.


  • Instantaneous power compensation in three-phase systems by using p-q-r theory

    by Hyosung Kim, F. Blaabjerg, B. Bak-Jensen, Jaeho Choi

    This paper proposes a novel power compensation algorithm in three-phase four-wire systems by using p-q-r theory. The p-q-r theory is compared with two previous instantaneous power theories, p-q theory and cross vector theory. The p-q-r theory provides two-degrees of freedom to control the system currents by only compensating the instantaneous imaginary power without using any energy storage element. The definition of powers maintains power conservation, and agrees well with the general understanding of power. Simulation results show the superiority of p-q-r theory both in definition and compensation.