TOTakahiro Okabe

Takahiro Okabe

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Takahiro Okabe has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Flexible thin-film thermal sensor for estimating thermal transport properties designed for biomaterial applications

    by Takahiro Okabe, Ayumi Shiroto, Yuto Hiyama, Katsuhisa Taguchi

    This study develops a flexible thin-film thermal sensor for estimating the key thermal transport properties of biomaterials, namely thermal conductivity, volumetric heat capacity, and thermal contact resistance. The sensor included a circular thin-film heater and three thin-film NTC thermistors mounted on a polyimide substrate, enabling simultaneous temperature measurements in regions of heat concentration and diffusion. These measurements were used in an inverse analysis based on a three-dimensional heat conduction model. To account for the variability in contact conditions, the thermal contact resistance between the sensor and sample surface was included as an unknown parameter. A trust-region reflective algorithm was used for robust minimization of the objective function. Validation was conducted using standard materials with known properties and porcine fat as a biological sample. The results showed excellent agreement between the measured and simulated temperature profiles. The estimated values for thermal conductivity and volumetric heat capacity closely matched reference values, and the thermal contact resistance was consistently in the order of 10−4 (m2 K)/W, likely owing to surface roughness. These results demonstrate the effectiveness of the proposed sensor and the inverse analysis method in enabling noninvasive and accurate evaluation of thermal transport properties in soft biological tissues.


  • A novel technique to diagnose non‐melanoma skin cancer by thermal conductivity measurements: Correlations with cancer stromal factors

    by Taku Fujimura, Takahiro Okabe, Kayo Tanita, Yota Sato, Chunbing Lyu, Yumi Kambayashi, Shigenao Maruyama, Setsuya Aiba

    The skin surface temperature reflects the physiological state of the human body. Quantitative methods of identification of skin cancers based on accurate measurement of effective thermal conductivity (ETC) are among the promising diagnostic tools for differentiating non‐invasive and invasive melanomas before surgical treatment. To validate these findings, in this report, the diagnostic methods for invasive and non‐invasive extramammary Paget’s disease (EMPD) and squamous cell carcinoma (SCC) were further tested by measuring the absolute value of skin surface temperature and the ETC of the skin. In addition, to investigate the stromal factors that might affect ETC, immunohistochemical staining for LL37, periostin (POSTN), MMP12, and MMP28 was performed. The invasive SCC and EMPD group showed a relatively higher skin surface temperature compared to the in situ SCC group. The non‐invasive EMPD and SCC group showed significantly lower values of ETC at lesions, whereas the invasive EMPD group showed significantly higher ETC values at lesions compared to healthy skin. Immunohistochemical staining showed that the percentage of LL37‐producing cells was significantly increased in invasive EMPD and SCC compared to that in non‐invasive EMPD and SCC. Moreover, Spearman's rank correlation test showed a significant inverse correlation between the percentage of MMP12‐positive cells and increased levels of ETC‐expressing areas in EMPD and SCC (r = −.5997). The present study suggested that differences in ETC could be a novel high‐accuracy diagnostic technique for non‐melanoma skin cancer, especially for detecting dermal invasion of SCC and EMPD.


  • Open Access

    First-in-human clinical study of novel technique to diagnose malignant melanoma via thermal conductivity measurements

    by Takahiro Okabe, Taku Fujimura, Junnosuke Okajima, Yumi Kambayashi, Setsuya Aiba, Shigenao Maruyama

    Melanoma is an aggressive skin cancer that originates from melanocytes and, especially in the case of early-stage melanoma, is distributed adjacent to the epidermis and superficial dermis. Although early-stage melanoma can be distinguished from benign nevus via a dermoscopy, it is difficult to distinguish invasive melanoma in its early stages from in situ melanoma. Because invasive melanoma must undergo a sentinel lymph node biopsy to be diagnosed, a non-invasive method to detect the micro-invasion of early-stage melanoma is needed for dermato-oncologists. This paper proposes a novel quantitative melanoma identification method based on accurate measurements of thermal conductivity using a pen-shaped device. This method requires skin temperature data for one minute to determine the effective thermal conductivity of the skin, allowing it to distinguish melanoma lesions from healthy skin. Results suggest that effective thermal conductivity was negative for in situ melanoma. However, in accordance with tumour progression, effective thermal conductivity was larger in invasive melanoma. The proposed thermal conductivity measurement is a novel tool that detects the micro-invasion of melanoma.


  • Fundamental study on cooling of biological phantom using ice slurry in limited space

    by Takahiro Okabe, Haruki Nishikawa, Taimei Miyagawa, Takao Inamura, Koji Fumoto

    The cooling process of a biological phantom using ice slurries with different geometries in a limited space was experimentally investigated. Ice slurry has recently been considered to as a solution to cool organs in the abdominal cavity efficiently and rapidly to suppress biological reactions during minimally invasive laparoscopic surgeries. However, previous studies have not focused on the interactions between ice slurry and biological tissues in the abdominal area. In this study, we aimed to investigate the effects of ice slurry geometry, enclosure width Lw, and mimic-blood flow rate Qb on the cooling of a biological phantom using ice slurry in a limited space. We prepared the same volume of ice slurry using different geometries with an ice packing factor of 25 wt% using a scraper-type method to place on the phantom surface. We observed the melting behaviors of the ice slurries and measured the surface and core temperatures of the biological phantom. It was found that the supply methods of the ice slurry affected the cooling of biological tissues significantly. When the ice slurry width was the same as that of the enclosure, the ice slurry floated on the melted slurry and inhibited the cooling of the biological phantom. When the slurry width was small compared to that of the enclosure, the slurry remained in contact with the phantom, thus resulting in its efficient and rapid cooling. The mimic-blood flow promoted the melting of the ice slurry increased the heat flux on the phantom surface. However, the core temperature was not affected. Thus, the core temperature cannot be reduced unless the blood flow is occluded.


  • Open Access

    Effect of Prefilmer Edge Thickness on Breakup Phenomena of Liquid Film in Prefilming Airblast Atomizer

    by Takahiro Okabe, Naoki Katagata, Toshihiro Sakaki, Takao Inamura, Koji Fumoto

    This paper describes the investigation of the effect of a prefilmer edge thickness on the breakup phenomena of aliquid film in a prefilmer airblast atomizer. The breakup phenomena of the liquid film at five prefilmer edge thicknesses (160, 500, 1250, 2000, and 3000 μm) under various conditions was observed using a high-speed camera. The breakup length of the liquid film was calculated by an image processing technique developed in this study. In order to quantitatively evaluate the effect of the prefilmer edge thickness on the breakup frequency, the Fast Fourier Transformation (FFT) analysis was conducted based on the time evolution of the breakup length. The results indicated that the breakup length increase and the breakup frequency decreases by increasing prefilmer edge thickness due to a larger volume of a liquid accumulation attaching to the prefilmer edge. The FFT analysis showed that the increase in prefilmer edge thickness causes the transition of the maximal power spectrum to a lower frequency (i.e. less than 100 Hz) due to the increase in the liquid accumulation at the edge as well. Finally, adimensionless correlation has been proposed for the breakup length of a liquid film.DOI: http://dx.doi.org/10.4995/ILASS2017.2017.4931