Qiong Du
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Qiong Du has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Jing Yang
Department of Pharmacy, Wuhan General Hospital of the Chinese People's Liberation Army, Hubei, China
1 shared publication - Jinjuan He
Department of Respiratory and Critical Medical, Taihe Hospital, Hubei University of Medicine, Hubei, China
1 shared publication - Meifang Wang
Department of Respiratory and Critical Care Medicine, Taihe Hospital, Hubei University of Medicine, Shiyan, China
1 shared publication - Peng Wu
Department of Clinical Laboratory, Taihe Hospital, Hubei University of Medicine, Hubei, China
1 shared publication - Xueqin Cheng
Department of Respiratory and Critical Medical, Taihe Hospital, Hubei University of Medicine, Shiyan, Hubei, China
1 shared publication - Yijun Tang
Clinical Molecular Diagnostic Center, Taihe Hospital, Hubei University of Medicine, Shiyan, China
1 shared publication
Latest Publications
- Open Access
- 26 February 2019
- Published by Springer Nature in AMB Express
- Vol. 9 (1) , 1-9
Visual and rapid detection of Acinetobacter baumannii by a multiple cross displacement amplification combined with nanoparticles-based biosensor assay
The traditional microbiological methods used for detecting Acinetobacter baumannii were usually time-consuming and labor-intensive. Thus, we sought to establish a novel rapid detecting method for target pathogen. A set of multiple cross displacement amplification (MCDA) primers was designed to recognize 10 different regions of the pgaD gene, which was conservative and specific for the bacterium. In the MCDA system, amplification primers D1 and R1 were 5′-labeled with FITC (fluorescein) and biotin, respectively. Numerous FITC- and biotin-attached duplex amplicons were formed during the amplification stage, which were detected by nanoparticles-based lateral flow biosensors (LFB) through immunoreactions (FITC on the duplex and anti-FITC on the LFB test line) and biotin/streptavidin interaction (biotin on the duplex and streptavidin on the nanoparticles). The results showed that the optimized reaction condition of MCDA-LFB method was 62 °C within 25 min. There was no cross reaction with non-A. baumannii species and the non-Acinetobacter genera, and the detection limit for DNA samples was 100 fg/reaction. For 135 sputum samples, the detection results showed that the detection ability of MCDA-LFB assay was superior to the culture methods and conventional PCR. Therefore, MCDA-LFB assay could be a potential tool for the rapid detection of A. baumannii in clinical samples and low resource areas.
- 26 February 2019
- Published by Springer Nature in AMB Express
- Vol. 9 (1) , 1-9
Open AccessVisual and rapid detection of Acinetobacter baumannii by a multiple cross displacement amplification combined with nanoparticles-based biosensor assay
The traditional microbiological methods used for detecting Acinetobacter baumannii were usually time-consuming and labor-intensive. Thus, we sought to establish a novel rapid detecting method for target pathogen. A set of multiple cross displacement amplification (MCDA) primers was designed to recognize 10 different regions of the pgaD gene, which was conservative and specific for the bacterium. In the MCDA system, amplification primers D1 and R1 were 5′-labeled with FITC (fluorescein) and biotin, respectively. Numerous FITC- and biotin-attached duplex amplicons were formed during the amplification stage, which were detected by nanoparticles-based lateral flow biosensors (LFB) through immunoreactions (FITC on the duplex and anti-FITC on the LFB test line) and biotin/streptavidin interaction (biotin on the duplex and streptavidin on the nanoparticles). The results showed that the optimized reaction condition of MCDA-LFB method was 62 °C within 25 min. There was no cross reaction with non-A. baumannii species and the non-Acinetobacter genera, and the detection limit for DNA samples was 100 fg/reaction. For 135 sputum samples, the detection results showed that the detection ability of MCDA-LFB assay was superior to the culture methods and conventional PCR. Therefore, MCDA-LFB assay could be a potential tool for the rapid detection of A. baumannii in clinical samples and low resource areas.