Sayan Acharya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sayan Acharya has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Subhashish Bhattacharya
North Carolina State University
21 shared publications - Anup Anurag
Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC, USA
10 shared publications Ghanshyamsinh Gohil
Department of Electrical and Computer Engineering, University of Texas at Dallas, TX, USA
4 shared publicationsGovind Chavan
North Carolina State University, Raleigh, NC 27695
4 shared publicationsRitwik Chattopadhyay
Authors are with FREEDM Systems Center, Department of ECE North Carolina State University Raleigh North Carolina USA
4 shared publicationsKasunaidu Vechalapu
FREEDM Systems Center, Department of Electrical and Computer Engineering North Carolina State University, Raleigh, NC 27606
3 shared publications
Latest Publications
- 30 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (5) , 5606-5624
A Three-Phase Active-Front-End Converter System Enabled by 10-kV SiC MOSFETs Aimed at a Solid-State Transformer Application
The use of high-voltage silicon carbide (SiC) devices can eliminate multilevel and cascaded converters and their complicated control strategies, making converter systems simple and reliable. A three-phase two-level voltage-source converter system serves as a simple converter system for interfacing any dc source to a three-phase grid. However, when the high-voltage devices are used in two-level converters, they are exposed to a high-voltage peak stress and a high $dv/dt$ (up to 100 kV/ $\mu$ s). Operating these semiconductor devices at these stress levels requires careful design not only of the semiconductor die and the module, but also of the gate drivers, busbars, and passive filters. This article demonstrates the operation of 10-kV SiC mosfet s and discusses the design considerations, advantages, and challenges associated with the operation of the three-phase two-level medium-voltage converter system used as the active-front-end converter system. Reliable operation of the medium-voltage converter system requires the development of reliable high-voltage modules and auxiliary parts, such as gate drivers, busbars, inductors, voltage and current sensors, and proper design of the controller system. Successful tests demonstrating continuous field operation of the medium-voltage active-front-end converter at a nominal rating of 7.2-kV dc-link voltage is demonstrated for the first time in the literature. The results indicate that these devices can accelerate the growth and deployment of medium-voltage SiC devices for field operation, as demonstrated by the operation inside the mobile container.
- 30 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (5) , 5606-5624
A Three-Phase Active-Front-End Converter System Enabled by 10-kV SiC MOSFETs Aimed at a Solid-State Transformer Application
The use of high-voltage silicon carbide (SiC) devices can eliminate multilevel and cascaded converters and their complicated control strategies, making converter systems simple and reliable. A three-phase two-level voltage-source converter system serves as a simple converter system for interfacing any dc source to a three-phase grid. However, when the high-voltage devices are used in two-level converters, they are exposed to a high-voltage peak stress and a high $dv/dt$ (up to 100 kV/ $\mu$ s). Operating these semiconductor devices at these stress levels requires careful design not only of the semiconductor die and the module, but also of the gate drivers, busbars, and passive filters. This article demonstrates the operation of 10-kV SiC mosfet s and discusses the design considerations, advantages, and challenges associated with the operation of the three-phase two-level medium-voltage converter system used as the active-front-end converter system. Reliable operation of the medium-voltage converter system requires the development of reliable high-voltage modules and auxiliary parts, such as gate drivers, busbars, inductors, voltage and current sensors, and proper design of the controller system. Successful tests demonstrating continuous field operation of the medium-voltage active-front-end converter at a nominal rating of 7.2-kV dc-link voltage is demonstrated for the first time in the literature. The results indicate that these devices can accelerate the growth and deployment of medium-voltage SiC devices for field operation, as demonstrated by the operation inside the mobile container.
- 30 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 10 (2) , 1519-1536
A Gen-3 10-kV SiC MOSFET-Based Medium-Voltage Three-Phase Dual Active Bridge Converter Enabling a Mobile Utility Support Equipment Solid State Transformer
The emergence of medium-voltage silicon carbide (SiC) power semiconductor devices, in ranges of 10–15 kV, has led to the development of simple two-level converter systems for medium-voltage applications. A medium-voltage mobile utility support equipment-based three-phase solid state transformer (MUSE-SST) system, based on Gen3 10 kV SiC MOSFETs, is developed to interconnect a three-phase 4160 V/60 Hz grid to a three-phase 480 V/60 Hz grid to provide a shore-to-ship power interface for naval vessels. The MUSE-SST system consists of three power conversion stages, namely, MVac/MVdc stage (MV: active front-end converter), MVdc/LVdc stage (dual active bridge converter), and LVdc/LVac stage (LV: active front-end converter). The galvanic isolation is introduced in the MVdc/LVdc stage using MV/LV high-frequency transformers (HFTs). This article demonstrates the operation of the three-phase Y–$\Delta $ connected dual active bridge converter used in the MVdc/LVdc stage of the MUSE-SST system. Equations for phase currents, power flow, and zero-voltage switching (ZVS) boundaries are derived for all possible modes for the three-phase Y–$\Delta $ configuration. A detailed parasitic simulation model is derived by measuring and experimentally verifying the parasitic elements of the HFT. A brief discussion regarding the design considerations required for the hardware development of the medium- and low-voltage sides of the three-phase dual active bridge converter is also provided. Successful tests demonstrating the operation and feasibility of the medium-voltage dual active bridge converter, at medium-voltage levels (7.2 kV dc-link voltage), are shown. The results indicate that these devices can accelerate the growth and deployment of the medium-voltage SiC-based converter for isolated and bidirectional medium- to low-voltage dc systems.- 30 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 10 (2) , 1519-1536
A Gen-3 10-kV SiC MOSFET-Based Medium-Voltage Three-Phase Dual Active Bridge Converter Enabling a Mobile Utility Support Equipment Solid State Transformer
The emergence of medium-voltage silicon carbide (SiC) power semiconductor devices, in ranges of 10–15 kV, has led to the development of simple two-level converter systems for medium-voltage applications. A medium-voltage mobile utility support equipment-based three-phase solid state transformer (MUSE-SST) system, based on Gen3 10 kV SiC MOSFETs, is developed to interconnect a three-phase 4160 V/60 Hz grid to a three-phase 480 V/60 Hz grid to provide a shore-to-ship power interface for naval vessels. The MUSE-SST system consists of three power conversion stages, namely, MVac/MVdc stage (MV: active front-end converter), MVdc/LVdc stage (dual active bridge converter), and LVdc/LVac stage (LV: active front-end converter). The galvanic isolation is introduced in the MVdc/LVdc stage using MV/LV high-frequency transformers (HFTs). This article demonstrates the operation of the three-phase Y–$\Delta $ connected dual active bridge converter used in the MVdc/LVdc stage of the MUSE-SST system. Equations for phase currents, power flow, and zero-voltage switching (ZVS) boundaries are derived for all possible modes for the three-phase Y–$\Delta $ configuration. A detailed parasitic simulation model is derived by measuring and experimentally verifying the parasitic elements of the HFT. A brief discussion regarding the design considerations required for the hardware development of the medium- and low-voltage sides of the three-phase dual active bridge converter is also provided. Successful tests demonstrating the operation and feasibility of the medium-voltage dual active bridge converter, at medium-voltage levels (7.2 kV dc-link voltage), are shown. The results indicate that these devices can accelerate the growth and deployment of the medium-voltage SiC-based converter for isolated and bidirectional medium- to low-voltage dc systems.- Open Access
- 20 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 15228-15238
Analytical Study of SiC MOSFET Based Inverter Output dv/dt Mitigation and Loss Comparison With a Passive dv/dt Filter for High Frequency Motor Drive Applications
Fast switching characteristic of wide bandgap devices enables high switching frequency of power devices and thereby, can facilitate high fundamental frequency operation of electrical machines. However, with the switching transition times in orders of tens of nanoseconds, the high dv/dt is observed across the switching device. The high dv/dt experienced by the switches, and consequently by the machine, can degrade winding insulations or bearings over a period of time. Therefore, it is imperative to maintain the dv/dt below recommended values depending on the machine insulation. The dv/dt across the devices can be adjusted by varying the gate resistance. A high value of gate resistance, however, introduces additional switching losses on the device. Using different dv/dt filtering techniques can also help to control the dv/dt on the machine terminals. These techniques do not increase the switching losses on the device. However, it introduces additional losses in the filter resistors and also increases the cost of the system. In this paper, an analysis based on the impact of gate resistance on the dv/dt across the machine, and the corresponding losses is carried out. An analytical dv/dt filter design strategy is proposed to limit the dv/dt to a particular value. With the proposed design scheme, the value of each filter component can be easily obtained, and filter losses can be estimated accurately. Lastly, a comparison is performed on the basis of efficiency between these two techniques.
- 20 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 15228-15238
Open AccessAnalytical Study of SiC MOSFET Based Inverter Output dv/dt Mitigation and Loss Comparison With a Passive dv/dt Filter for High Frequency Motor Drive Applications
Fast switching characteristic of wide bandgap devices enables high switching frequency of power devices and thereby, can facilitate high fundamental frequency operation of electrical machines. However, with the switching transition times in orders of tens of nanoseconds, the high dv/dt is observed across the switching device. The high dv/dt experienced by the switches, and consequently by the machine, can degrade winding insulations or bearings over a period of time. Therefore, it is imperative to maintain the dv/dt below recommended values depending on the machine insulation. The dv/dt across the devices can be adjusted by varying the gate resistance. A high value of gate resistance, however, introduces additional switching losses on the device. Using different dv/dt filtering techniques can also help to control the dv/dt on the machine terminals. These techniques do not increase the switching losses on the device. However, it introduces additional losses in the filter resistors and also increases the cost of the system. In this paper, an analysis based on the impact of gate resistance on the dv/dt across the machine, and the corresponding losses is carried out. An analytical dv/dt filter design strategy is proposed to limit the dv/dt to a particular value. With the proposed design scheme, the value of each filter component can be easily obtained, and filter losses can be estimated accurately. Lastly, a comparison is performed on the basis of efficiency between these two techniques.
- 18 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 2 (1) , 1-12
Gate Drivers for Medium-Voltage SiC Devices
Extensive research in wide-bandgap material technology such as silicon carbide (SiC) has led to the development of medium-voltage (MV) power semiconductor devices with blocking voltages of 3.3 to 15 kV. When these devices are used in various applications, they are exposed to a high peak voltage stress and a very high dv/dt (50-100 V/ns). These impose stringent requirements on the gate driving stage for these devices in terms of featuring a high isolation voltage capability along with a high dv/dt ruggedness, which makes it necessary to have an ultralow coupling capacitance between primary and secondary sides of the gate drivers. One of the key issues in achieving this MV insulation pertains to the necessary clearance and creepage requirements, as defined in IEC 61800-5-1 standards. While the successful operation of these gate drivers is demonstrated in MV converter applications such as solid-state transformers, and MV grid-connected inverters, substantial research needs to be carried out to improve the gate drivers' performance and provide a plug-and-play solution. This article aims to comprehensively review these gate drivers and consolidate various required design features concerning their galvanic isolation stage, based on normal and short-circuit operation of MV high-power converter systems. Different device short-circuit protection schemes for these gate drivers are explored in detail. Additional applications and functionalities of the gate drivers, including gate drivers used inthe series-connection of MV devices and intelligent gate drivers, are also provided in brief. Based on prior research, this review aims to provide design choices and guidelines for the gate drivers, accelerating the growth and deployment of MV SiC devices for field applications.
- 18 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 2 (1) , 1-12
Gate Drivers for Medium-Voltage SiC Devices
Extensive research in wide-bandgap material technology such as silicon carbide (SiC) has led to the development of medium-voltage (MV) power semiconductor devices with blocking voltages of 3.3 to 15 kV. When these devices are used in various applications, they are exposed to a high peak voltage stress and a very high dv/dt (50-100 V/ns). These impose stringent requirements on the gate driving stage for these devices in terms of featuring a high isolation voltage capability along with a high dv/dt ruggedness, which makes it necessary to have an ultralow coupling capacitance between primary and secondary sides of the gate drivers. One of the key issues in achieving this MV insulation pertains to the necessary clearance and creepage requirements, as defined in IEC 61800-5-1 standards. While the successful operation of these gate drivers is demonstrated in MV converter applications such as solid-state transformers, and MV grid-connected inverters, substantial research needs to be carried out to improve the gate drivers' performance and provide a plug-and-play solution. This article aims to comprehensively review these gate drivers and consolidate various required design features concerning their galvanic isolation stage, based on normal and short-circuit operation of MV high-power converter systems. Different device short-circuit protection schemes for these gate drivers are explored in detail. Additional applications and functionalities of the gate drivers, including gate drivers used inthe series-connection of MV devices and intelligent gate drivers, are also provided in brief. Based on prior research, this review aims to provide design choices and guidelines for the gate drivers, accelerating the growth and deployment of MV SiC devices for field applications.
- 4 November 2020
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 16 (1) , 127-138
A 10‐kV SiC‐MOSFET (Gen‐3) Half‐Bridge Module‐Based Isolated Bidirectional DC–DC Converter Block for Medium‐Voltage High‐Power Applications
The packaging technology for the medium‐voltage silicon carbide (SiC)‐metal oxide semiconductor field‐effect transistor (MOSFETs) has come a long way since its inception. Now, it is feasible to design half‐bridge power modules based on 10‐kV SiC‐MOSFETs for higher current applications. This paves the way for many application areas for these devices, particularly for medium‐voltage and high‐power applications. This paper presents a design of a modular medium‐voltage, high‐power isolated DC–DC converter enabled by these 10‐kV SiC‐MOSFETs‐based power modules. The design objectives are targeted at increasing the efficiency, power density, and interoperability. The proposed DC–DC converter is aimed for applications like DC distribution for the data centers, subsea power transmission, offshore wind farms, and photovoltaic energy transmission–distribution–coordination; electric ship DC power transmission; solid‐state distribution transformer, etc. © 2020 Institute of Electrical Engineers of Japan. Published by Wiley Periodicals LLC.
- 4 November 2020
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 16 (1) , 127-138
A 10‐kV SiC‐MOSFET (Gen‐3) Half‐Bridge Module‐Based Isolated Bidirectional DC–DC Converter Block for Medium‐Voltage High‐Power Applications
The packaging technology for the medium‐voltage silicon carbide (SiC)‐metal oxide semiconductor field‐effect transistor (MOSFETs) has come a long way since its inception. Now, it is feasible to design half‐bridge power modules based on 10‐kV SiC‐MOSFETs for higher current applications. This paves the way for many application areas for these devices, particularly for medium‐voltage and high‐power applications. This paper presents a design of a modular medium‐voltage, high‐power isolated DC–DC converter enabled by these 10‐kV SiC‐MOSFETs‐based power modules. The design objectives are targeted at increasing the efficiency, power density, and interoperability. The proposed DC–DC converter is aimed for applications like DC distribution for the data centers, subsea power transmission, offshore wind farms, and photovoltaic energy transmission–distribution–coordination; electric ship DC power transmission; solid‐state distribution transformer, etc. © 2020 Institute of Electrical Engineers of Japan. Published by Wiley Periodicals LLC.
- 11 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 8 (1) , 486-494
Thermal Performance and Reliability Analysis of a Medium-Voltage Three-Phase Inverter Considering the Influence of High $dv/dt$ on Parasitic Filter ElementsIn recent years, the use of silicon carbide (SiC) power semiconductor devices in medium-voltage (MV) applications has been made possible due to the development of high blocking voltage (10-15 kV)-based devices. While the use of these devices brings in a lot of advantages, the semiconductor devices are exposed to high peak stress (of up to 15 kV) and a very high dv/dt (of up to 100 kV/μs). The high dv/dt across the devices leads to a high dv/dt across other components connected to the system. This makes the effect of the parasitic capacitance across the components to be of paramount importance since an additional current flows through the components and, consequently, through the switching device. This additional current flows during each switching transition and leads to increased switching losses in the device. This article analyzes the effect of these additional losses on the lifetime of the device. The thermal performance of a three-phase inverter power block is provided, and a mission profile (solar irradiance and temperature)-based analysis is carried out to account for the additional junction temperature rise. The rainflow counting method is implemented to identify the mean and amplitude of each thermal cycle. An empirical device lifetime model is used to calculate the number of cycles to failure. Finally, the Palgrem Miner rule is used to quantify the total damage in the device. Comparisons have been carried out on basis of lifetime for both the cases (with and without the influence of parasitic capacitances). This analysis can be helpful in validating the importance of the design of filter inductors in these MV applications.
- 11 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 8 (1) , 486-494
Thermal Performance and Reliability Analysis of a Medium-Voltage Three-Phase Inverter Considering the Influence of High $dv/dt$ on Parasitic Filter ElementsIn recent years, the use of silicon carbide (SiC) power semiconductor devices in medium-voltage (MV) applications has been made possible due to the development of high blocking voltage (10-15 kV)-based devices. While the use of these devices brings in a lot of advantages, the semiconductor devices are exposed to high peak stress (of up to 15 kV) and a very high dv/dt (of up to 100 kV/μs). The high dv/dt across the devices leads to a high dv/dt across other components connected to the system. This makes the effect of the parasitic capacitance across the components to be of paramount importance since an additional current flows through the components and, consequently, through the switching device. This additional current flows during each switching transition and leads to increased switching losses in the device. This article analyzes the effect of these additional losses on the lifetime of the device. The thermal performance of a three-phase inverter power block is provided, and a mission profile (solar irradiance and temperature)-based analysis is carried out to account for the additional junction temperature rise. The rainflow counting method is implemented to identify the mean and amplitude of each thermal cycle. An empirical device lifetime model is used to calculate the number of cycles to failure. Finally, the Palgrem Miner rule is used to quantify the total damage in the device. Comparisons have been carried out on basis of lifetime for both the cases (with and without the influence of parasitic capacitances). This analysis can be helpful in validating the importance of the design of filter inductors in these MV applications.
- 5 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power Electronics Magazine
- Vol. 6 (3) , 18-31
Gate Drivers for High-Frequency Application of Silicon-Carbide MOSFETs: Design considerations for faster growth of LV and MV applications
With the advent of wide-bandgap (WBG) semiconductor devices, silicon-carbide (SiC)-based MOSFETs for high voltage and current serve as a viable replacement for conventional Si-based IGBTs [1], [2]. SiC-based MOSFETs combine the advantages of both IGBTs and MOSFETs, have a low on-state resistance at a high-voltage rating (similar to IGBTs), and lower-switching losses than those of Si MOSFETs, thus making it closer to an ideal switch [3]. This makes it possible for SiC MOSFETs to process high power at high-switching frequencies without compromising the efficiency of the system [4]. Due to the inherent lower on-state specific resistance and faster switching speeds in SiC MOSFETs, it is also possible to develop and use medium-voltage (MV) power semiconductor devices greater than 6.5 kV without experiencing very high losses [5]. The SiC MOSFET design and development can be divided into two broad categories: low-voltage (LV)-blocking (3.3-kV) SiC MOSFETs [6]. Although MV SiC MOSFETs can enable niche applications, there is widespread use of LV-blocking power devices in various applications such as renewable energy, drives for electrical machines, power converters for electric vehicles, and so on, whereas SiC MOSFETs can offer a multitude of advantages over Si IGBTs [7], [8].
- 5 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power Electronics Magazine
- Vol. 6 (3) , 18-31
Gate Drivers for High-Frequency Application of Silicon-Carbide MOSFETs: Design considerations for faster growth of LV and MV applications
With the advent of wide-bandgap (WBG) semiconductor devices, silicon-carbide (SiC)-based MOSFETs for high voltage and current serve as a viable replacement for conventional Si-based IGBTs [1], [2]. SiC-based MOSFETs combine the advantages of both IGBTs and MOSFETs, have a low on-state resistance at a high-voltage rating (similar to IGBTs), and lower-switching losses than those of Si MOSFETs, thus making it closer to an ideal switch [3]. This makes it possible for SiC MOSFETs to process high power at high-switching frequencies without compromising the efficiency of the system [4]. Due to the inherent lower on-state specific resistance and faster switching speeds in SiC MOSFETs, it is also possible to develop and use medium-voltage (MV) power semiconductor devices greater than 6.5 kV without experiencing very high losses [5]. The SiC MOSFET design and development can be divided into two broad categories: low-voltage (LV)-blocking (3.3-kV) SiC MOSFETs [6]. Although MV SiC MOSFETs can enable niche applications, there is widespread use of LV-blocking power devices in various applications such as renewable energy, drives for electrical machines, power converters for electric vehicles, and so on, whereas SiC MOSFETs can offer a multitude of advantages over Si IGBTs [7], [8].
- 5 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 8 (2) , 1644-1656
An Accurate Calorimetric Loss Measurement Method for SiC MOSFETs
An accurate measurement of conduction and switching losses in the power semiconductor devices is necessary in order to design and evaluate the thermal management system of modern converter systems. Conventionally, electrical measurement methods, such as the double-pulse tests (DPT) are used for measuring the switching losses. However, with the advent of widebandgap (WBG) devices, which have fast switching transients, it is rather difficult to capture the waveforms accurately during switching transitions, and consequently the measurement of switching loss becomes inaccurate. In addition, the measurement of switching waveforms depends on the voltage and current probes, as well as the oscilloscope used for the measurement which makes this method prone to errors. This necessitates the use of measurement methods which can provide much higher accuracy than existing conventional electrical methods. Calorimetric methods are based on comparatively slow temperature measurements, and do not rely on measurements of fast switching transitions of voltages and currents, thus eliminating the demand for measuring fast switching transitions. This paper presents an accurate calorimetric method for measuring the device losses which can be used to determine individual loss components accurately (conduction loss, turn-on loss and turn-off losses). In addition to the turn-on and turn-off losses, this method can evaluate the charging and discharging losses of the device. The novelty of the method lies in the fact that a single setup can be used to measure all possible losses that can occur in a device during converter operation. The calorimetric test setup is described and a novel modulation scheme is introduced which enables the segregation of the individual losses. The experimental test setup is built and the method is verified by measuring the losses of a 900 V, 23 A Wolfspeed C3M0120090D SiC MOSFET.
- 5 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 8 (2) , 1644-1656
An Accurate Calorimetric Loss Measurement Method for SiC MOSFETs
An accurate measurement of conduction and switching losses in the power semiconductor devices is necessary in order to design and evaluate the thermal management system of modern converter systems. Conventionally, electrical measurement methods, such as the double-pulse tests (DPT) are used for measuring the switching losses. However, with the advent of widebandgap (WBG) devices, which have fast switching transients, it is rather difficult to capture the waveforms accurately during switching transitions, and consequently the measurement of switching loss becomes inaccurate. In addition, the measurement of switching waveforms depends on the voltage and current probes, as well as the oscilloscope used for the measurement which makes this method prone to errors. This necessitates the use of measurement methods which can provide much higher accuracy than existing conventional electrical methods. Calorimetric methods are based on comparatively slow temperature measurements, and do not rely on measurements of fast switching transitions of voltages and currents, thus eliminating the demand for measuring fast switching transitions. This paper presents an accurate calorimetric method for measuring the device losses which can be used to determine individual loss components accurately (conduction loss, turn-on loss and turn-off losses). In addition to the turn-on and turn-off losses, this method can evaluate the charging and discharging losses of the device. The novelty of the method lies in the fact that a single setup can be used to measure all possible losses that can occur in a device during converter operation. The calorimetric test setup is described and a novel modulation scheme is introduced which enables the segregation of the individual losses. The experimental test setup is built and the method is verified by measuring the losses of a 900 V, 23 A Wolfspeed C3M0120090D SiC MOSFET.