GKGrace E. Kim

Grace E. Kim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Grace E. Kim has a total of 81 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of Scheduled Inpatient Saturday Endoscopies on Length of Stay and Cost at a Large Tertiary Center

    by Grace E. Kim, Joseph Galan, Robert Zabala, Uzma D. Siddiqui, K. Gautham Reddy

  • Open Access

    Artificial Intelligence for Lymph Node Detection and Malignancy Prediction in Endoscopic Ultrasound: A Multicenter Study

    by Belén Agudo Castillo, Miguel Mascarenhas Saraiva, António Miguel Martins Pinto da Costa, João Ferreira, Miguel Martins, Francisco Mendes, Pedro Cardoso, Joana Mota, Maria João Almeida, João Afonso, et al.

    Background/Objectives: Endoscopic ultrasound (EUS) is crucial for lymph node (LN) characterization, playing a key role in oncological staging and treatment guidance. EUS criteria for predicting malignancy are imprecise, and histologic diagnosis may have limitations. This multicenter study aimed to evaluate the effectiveness of a novel artificial intelligence (AI)–based system in predicting LN malignancy from EUS images. Methods: This multicenter study included EUS images from nine centers. Lesions were labeled (“malignant” or “benign”) and delimited with bounding boxes. Definitive diagnoses were based on cytology/biopsy or surgical specimens and, if negative, a minimum six-month clinical follow-up. A convolutional neural network (CNN) was developed using the YOLO (You Only Look Once) architecture, incorporating both detection and classification modules. Results: A total of 59,992 images from 82 EUS procedures were analyzed. The CNN distinguished malignant from benign lymph nodes with a sensitivity of 98.8% (95% CI: 98.5–99.2%), specificity of 99.0% (95% CI: 98.3–99.7%), and precision of 99.0% (95% CI: 98.4–99.7%). The negative and positive predictive values for malignancy were 98.8% and 99.0%, respectively. Overall diagnostic accuracy was 98.3% (95% CI: 97.6–99.1%). Conclusions: This is the first study evaluating the performance of deep learning systems for LN assessment using EUS imaging. Our AI-powered imaging model shows excellent detection and classification capabilities, emphasizing its potential to provide a valuable tool to refine LN evaluation with EUS, ultimately supporting more tailored, efficient patient care.


  • Liver Perforation From a Plastic Biliary Stent

    by Grace E. Kim, Divya Chalikonda, Dennis D. Chen


  • Large Single Center Comparison of Novel and Reusable Duodenoscopes Shows Similar Contamination Rates That Do Not Correlate With Clinical Infection

    by Sriya S. Muralidharan, Divya Chalikonda, Grace E. Kim, Miles Breese, Marilu Andrade, Eric Montminy, Dennis Chen, Uzma D. Siddiqui

    INTRODUCTION: There are limited data comparing the contamination rates of reusable and novel duodenoscopes with disposable components. The clinical implications of novel duodenoscope bacterial contamination are also unknown. This study aimed to evaluate the rate of pathogenic bacterial contamination of novel and reusable duodenoscopes and assess the clinical implications for patients exposed to contaminated duodenoscopes. METHODS: We conducted an observational study of the bacterial contamination of reusable duodenoscopes and novel duodenoscopes with disposable caps (which do not have disposable elevators). After identification of positive cultures from duodenoscopes, corresponding patient charts were reviewed for blood culture data or evidence of sepsis by quick sequential organ failure assessment and systemic inflammatory response syndrome criteria. RESULTS: The contamination rate of reusable duodenoscopes was 0.80% (95% confidence interval −0.05% to 1.65%). The contamination rate of novel duodenoscopes was 0.0%. The contamination rates were not significantly different ( P = 0.141). In reusable duodenoscopes, >1 colony-forming unit of Gram-negative rods was identified in 4 positive cultures. None of the patients exposed to a positive culture had an existing infection nor developed bacteremia or sepsis after endoscopic retrograde cholangiopancreatography. DISCUSSION: Our data suggest bacterial contamination rates of novel duodenoscopes with disposable caps and reusable duodenoscopes are similar. The low contamination rates in this study support consistent high-level disinfection practices regardless of duodenoscope generation.


  • Open Access

    A rendezvous approach for ampullary access in a strictured duodenojejunostomy

    by Grace E. Kim, Bradford Chong, Osman Ahmed, Jeffrey B. Matthews, Dennis D. Chen, Uzma D. Siddiqui, Eric Montminy

  • High Diagnostic Yield of Fine Needle Biopsy for Pancreatic Serous Cystadenomas—A Multicenter Study

    by Grace E. Kim, Michael Mercado, Margarita Riojas Barrett, Miles Breese, Shifa Umar, Fares Ayoub, Dennis Chen, Mohamed O. Othman, Uzma D. Siddiqui

    Background: Distinguishing serous cystadenoma (SCA), a benign pancreatic cyst, from potentially malignant mucinous pancreatic cystic lesions carries significant clinical and prognostic implications. While endoscopic ultrasound-guided fine needle aspiration is the standard diagnostic tool, its low diagnostic yield often results in additional workup. Objective: This study evaluates diagnostic yield of fine needle biopsy (FNB) on lesions suggestive of serous cystadenoma on endoscopic ultrasound (EUS). Materials and Methods: Patients with microcystic EUS appearance were identified database search from 2015 to 2022 and procedure information was obtained through a retrospective chart review from 2 large academic centers. Prior cross sectional imaging diagnosis was also obtained. All microcystic lesions with classic “honeycomb” appearance for SCA a on EUS were targeted for FNB and their pathology evaluated. Results: Thirty-one patients with suspected SCA who underwent EUS-FNB were included. EUS FNB was successful in obtaining diagnosis in 96.8% of patients. Serous cystadenoma was diagnosed via EUS FNB in 27 of 31 patients (87.1%). Of the remaining 4 patients, there was 1 invasive pancreatic ductal adenocarcinoma, 1 pancreatic neuroendocrine tumor, 1 intraductal papillary mucinous neoplasm, and 1 nondiagnostic sample. Conclusions: EUS-FNB sampling for histopathology is a safe and accurate diagnostic tool for pancreatic SCA. When microcytic lesions are found on endoscopic ultrasound, our study results suggest that fine needle biopsy for histopathology should be considered as the initial diagnostic evaluation tool given the demonstrated improved diagnostic yield for SCA.


  • Gastric Per-Oral Endoscopy Myotomy (G-POEM): Tips, Tricks, and Pitfalls

    by Grace E. Kim, Mahnoor Khan, Sunil Amin, Amrita Sethi

    Purpose of Review The number of hospitalizations for gastroparesis has risen over 300% in recent decades with increased physical, psychological, and healthcare burdens. Gastric per-oral endoscopic myotomy (G-POEM) is a promising therapy for patients with refractory gastroparesis. This article reviews important considerations for G-POEM. Recent Findings Predictive factors for clinical success after G-POEM include diabetic and idiopathic gastroparesis, shorter gastroparesis duration, symptoms predominant of nausea and emesis, and gastric emptying study showing gastric retention of > 20% at 4 h. Mucosal closure is a critical step for G-POEM; both sutures and clips have high success rates, with clips having a trend to lower success rates but with significantly shorter procedure time and cheaper cost. G-POEMs have an overall 61% pooled success rate at one year with a yearly 13% symptom recurrence rate. Summary A careful patient selection can yield higher clinical success rates. Further studies are needed on variant G-POEM techniques for more durable outcomes.


  • Open Access

    Transcatheter Arterial Radioembolization–Induced Gastric Ulcer in an Excluded Stomach After Roux-en-Y Gastric Bypass

    by Grace E. Kim, Dennis Chen

    Transcatheter arterial radioembolization (TARE) is a common locoregional treatment for hepatocellular carcinoma. It is associated with peptic ulcer disease in up to 5% of patients. A 70-year-old man with Roux-en-Y gastric bypass and liver cirrhosis with hepatocellular carcinoma treated with TARE 6 months earlier was evaluated for continued melena and was found to have an ulcer in the excluded stomach. This was successfully treated with liquid proton pump inhibitor through gastrostomy tube to the excluded stomach. This represents a unique case of successful management of TARE-induced peptic ulcer disease in the excluded stomach of a Roux-en-Y gastric bypass patient.