YTYusaku Tagawa

Yusaku Tagawa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yusaku Tagawa has a total of 43 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    In-situ fabrication of ultra-conformal nanomesh epidermal sensors on arbitrary skin surface

    by Xiaoping Liang, Ruiqi Guo, Hongting Chen, Yusaku Tagawa, Sunghoon Lee, Shuxu Wang, Buyun Yu, Masahito Takakuwa, Kento Yamagishi, Xun-En Wu, et al.

  • Open Access

    A Simple and Affordable Footwear‐Integrated Near‐Miss Slip Sensor for Detecting Latent Slip Risk During Gait

    by Yusaku Tagawa, Taiyu Okatani, Remi Takano, Tomoyuki Yokota, Hiroshi Onodera

    Slip‐related falls (SRFs) are a leading cause of injury in workplaces and daily life. Wearable inertial sensor systems can detect SRFs, but they do not directly measure available shoe–floor friction. Here, we propose a simple, affordable footwear‐integrated near‐miss slip sensor for investigating latent slip risk during gait. An elastic dome and a two‐stage structure convert changes in the contact stick–slip distribution into normal‐pressure signals. Finite‐element analyses and benchtop tests support this principle. The 15 mm 15 mm 14 mm (3150 mm 3 ) sensor is mounted on the shoe sole at a component cost of approximately US$25 per shoe. During walking, the per‐step pressure ratio distinguished a silicone‐oil–coated floor from the baseline floor ( p < 0.01), with a response time of 120 ms after heel strike. A more durable heel‐embedded variant was used for a secondary gait evaluation in four participants, capturing broader pressure waveforms on the slippery floor across walking speeds. These waveform changes describe gait‐related heel loading rather than direct friction measurement. The proposed sensor provides a compact approach to sensing low‐friction contact conditions associated with latent slip risk, without requiring gross slip. Further design improvements and calibration, combined with independent friction‐demand measurements, could support assessment of the friction margin during walking.

  • Open Access

    A body-scale textile-based electromyogram monitoring system with coaxially shielded conductive yarns

    by Sunghoon Lee, Kanta Takano, Wakako Yukita, Yusaku Tagawa, Lulu Sun, Shuxu Wang, Joo Sung Kim, Tomoyuki Yokota, Takao Someya

    A crucial aim of wearable electronics is to acquire biological signals from the body with high precision. However, obtaining high-accuracy electromyogram (EMG) signals from a large area surrounded by noise sources remains challenging. In this study, we present a body-scale textile-based wireless electromyogram monitoring system with coaxially shielded conductive yarns that can reduce the influence of surrounding noise. The wiring yarns comprise three stretchable components: a conductive signal yarn, polyurethane insulating layer, and shielding conductor. The introduction of the shielding conductor suppresses noise contamination. The noise level remains below 0.1 millivolts, despite the wiring being directly pressed at nominal contact pressures exceeding 30 kilopascals. The muscle activity at various shoulder joint angles is successfully recorded when another person directly touches the arm and wiring for support. Furthermore, EMG monitoring of the lower body is performed during dynamic activities such as countermovement jumps, jogging, and running.


  • Visualization and Analysis of Perfusion Cluster Velocity From a Large Area Near-Infrared Image Sensor

    by Adithya Naresh, Akihiko Fujisawa, Xingle Wang, Chung-Kai Chen, Naoki Takada, Gen Koide, Takashi Nakamura, Yusaku Tagawa, Tomoyuki Yokota, Takao Someya

    Flexible, large area, image sensors (FLA-IS) can enable the capture of additional biomarkers not found in current wearable devices with discrete optical sensors (d-os). To demonstrate, this study utilizes an in-house, near-infrared sensitive FLA-IS system to collect data from multiple volunteers on a finger test site. A custom processing algorithm is applied to reveal subcutaneous perfusion movement and quantify that into a blood flow velocity equivalent biomarker: perfusion cluster velocity (PcV). The paper analyzes the variability and repeatability of all the processed signals by tracking features representing duration between selected points of interest (POI) for PcV and reference photoplethysmography (PPG) waveforms per cardiac cycle. The resulting analyses show 24% improvement in dynamic range and 20% less cycle-to-cycle variation for PcV, and PcV, PPG features compared to PPG-only features, demonstrating FLA-IS' potential for advanced biomarker measurements.

  • Revealing the Effects of Inert Annealing on Low-Noise Near-Infrared Organic Photodetectors via Precise Trap and Noise Characterization

    by Yusaku Tagawa, Ryota Fukuzawa, Takao Someya, Tomoyuki Yokota

    The utilization of near-infrared (NIR) organic photodetectors (OPDs) holds considerable promise, primarily owing to their solution processability and flexibility characteristics. The recent reduction of dark current in the NIR-OPDs is critical for achieving high performance in OPDs using the narrow bandgap of the active layer. However, recent NIR-OPDs with excellent low-dark current exhibit measurement limitations, particularly regarding noise and trap measurements, which are crucial for evaluating specific detectivity and understanding the physics of the NIR-OPDs. This study comprehensively analyzes precise noise and trap measurements at varying inert annealing temperatures applied to the electron-transport layer. The optimized annealing process led to a high specific detectivity of 1.3 × 1013 cm Hz1/2 W–1 at 850 nm and a low trap density of 9.9 × 1013 cm–3 at a shallow-trap-energy level of 0.37 eV. The inert annealing process offers an example of typical issues, such as water-induced trap analysis. Our research explains some pitfalls of noise and trap measurements, addresses them adequately, and demonstrates their limitations. Noise-spectrum measurements should be conducted in a specific range limited by the shot-noise current and the gain bandwidth. In addition, the shallow and slight trap-density reduction can be captured by capacitance–voltage and capacitance–frequency measurements using a series resistance correction. The adequate measurement settings play a vital role in extracting the key physical characteristics of the recent high-performance OPD.


  • Open Access

    A water-resistant, ultrathin, conformable organic photodetector for vital sign monitoring

    by Baocai Du, Sixing Xiong, Lulu Sun, Yusaku Tagawa, Daishi Inoue, Daisuke Hashizume, Wenqing Wang, Ruiqi Guo, Tomoyuki Yokota, Shuxu Wang, et al.

    Ultrathin flexible photodetectors can be conformably integrated with the human body, offering promising advancements for emerging skin-interfaced sensors. However, the susceptibility to degradation in ambient and particularly in aqueous environments hinders their practical application. Here, we report a 3.2-micrometer-thick water-resistant organic photodetector capable of reliably monitoring vital sign while submerged underwater. Embedding the organic photoactive layer in an adhesive elastomer matrix induces multidimensional hybrid phase separation, enabling high adhesiveness of the photoactive layer on both the top and bottom surfaces with maintained charge transport. This improves the water-immersion stability of the photoactive layer and ensures the robust sealing of interfaces within the device, notably suppressing fluid ingression in aqueous environments. Consequently, our fabricated ultrathin organic photodetector demonstrates stability in deionized water or cell nutrient media over extended periods, high detectivity, and resilience to cyclic mechanical deformation. We also showcase its potential for vital sign monitoring while submerged underwater.


  • Top Cited Papers
    Open Access

    Low-Voltage Operating Ferroelectric FET with Ultrathin IGZO Channel for High-Density Memory Application

    by Fei Mo, Yusaku Tagawa, Chengji Jin, MinJu Ahn, Takuya Saraya, Toshiro Hiramoto, Masaharu Kobayashi

    We have fabricated and demonstrated ultrathin In-Ga-Zn-O (IGZO) channel ferroelectric HfO2 field effect transistor (FET) with memory operation. Ultrathin-body IGZO ferroelectric FET (FeFET) shows high mobility and nearly ideal subthreshold slop with minimum 8 nm channel thickness, thanks to the properties of IGZO material, junctionless FET operation, nearly-zero low-k interfacial layer on metal-oxide channel and effective capping for realizing ferroelectric phase formation with HfZrO2 (HZO). The controllable memory operations are achieved with the use of back gate. The design guideline of IGZO FeFET is proposed by discussing the thickness of front gate oxide HZO and back gate oxide SiO2 using TCAD simulation. The material and electrical properties of metal/HZO/IGZO/metal capacitor are also investigated. Metal/HZO/IGZO/metal capacitor has up to 108 endurance and over one-year retention. IGZO FeFET shows a potential for high-density and low-power memory application.


  • Open Access

    Ferroelectric HfO2 Tunnel Junction Memory With High TER and Multi-Level Operation Featuring Metal Replacement Process

    by Masaharu Kobayashi, Yusaku Tagawa, Fei Mo, Takuya Saraya, Toshiro Hiramoto

    We have investigated device design of HfO 2 -based ferroelectric tunnel junction (FTJ) memory. Asymmetry of dielectric screening property in top and bottom electrodes is the key for high tunneling electroresistance (TER) ratio. Thus, metal and semiconductor electrodes are proposed. There exists a design space of ferroelectric material parameters to achieve high TER ratio under the constraint of depolarizing field. We have developed an FTJ fabrication process to realize the design. Large polarization charge and symmetric switching voltage are obtained by top metal replacement process. High TER ratio >30 and multi-level cell operation have been successfully demonstrated. Retention characteristics is promising, however, endurance characteristics should be improved for reliable operation.