Xun Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xun Yu has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Junfeng Jiang
Tianjin University
6 shared publications - Shuang Wang
Tianjin University
6 shared publications - Tiegen Liu
Tianjin University
5 shared publications - Kun Liu
Tianjin University
4 shared publications - Mei Sang
Tianjin University
3 shared publications Shitao Peng
Tianjin University of Technology
3 shared publications
Latest Publications
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 44 (19) , 8789-8797
Robust High-Temperature Demodulation of Sapphire-Fiber MEMS Fabry-Pérot Pressure Sensors via Physics-Informed Multi-Domain Fusion
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 44 (19) , 8789-8797
Robust High-Temperature Demodulation of Sapphire-Fiber MEMS Fabry-Pérot Pressure Sensors via Physics-Informed Multi-Domain Fusion
- 27 March 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (7) , 12599-12610
Dispersion compensated spectral demodulation method for silicon-based Fabry-Pérot interferometric temperature sensors
The spectral demodulation method has been widely used in the interrogation of Fabry-Pérot (F-P) temperature sensors due to its high accuracy and large dynamic range, yet the dispersion of the cavity materials could lead to the failure of the calculation. A dispersion compensated spectral demodulation method for the fiber optical Silicon-based F-P temperature sensor was proposed in this article. The numerical model of the Silicon sensing F-P cavity was built using the thermal expansion and thermos-optic characteristics of the material, from which a compensation curve was proposed to counteract the dispersion-induced optic path difference (OPD) blue shift, in order to correctly solve the cavity’s OPD. Simulations showed that this method doesn’t introduce any degradation of precision compared to the traditional spectral demodulation method. The experiment also proved that the method avoided the dispersion-induced phase jump defects during the temperature experiment, which ranged from -40 to 100 °C. The proposed method guarantees the effective application for the use of spectral demodulation method in the silicon-based F-P temperature sensors.
- 27 March 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (7) , 12599-12610
Dispersion compensated spectral demodulation method for silicon-based Fabry-Pérot interferometric temperature sensors
The spectral demodulation method has been widely used in the interrogation of Fabry-Pérot (F-P) temperature sensors due to its high accuracy and large dynamic range, yet the dispersion of the cavity materials could lead to the failure of the calculation. A dispersion compensated spectral demodulation method for the fiber optical Silicon-based F-P temperature sensor was proposed in this article. The numerical model of the Silicon sensing F-P cavity was built using the thermal expansion and thermos-optic characteristics of the material, from which a compensation curve was proposed to counteract the dispersion-induced optic path difference (OPD) blue shift, in order to correctly solve the cavity’s OPD. Simulations showed that this method doesn’t introduce any degradation of precision compared to the traditional spectral demodulation method. The experiment also proved that the method avoided the dispersion-induced phase jump defects during the temperature experiment, which ranged from -40 to 100 °C. The proposed method guarantees the effective application for the use of spectral demodulation method in the silicon-based F-P temperature sensors.
- 11 February 2026
- Published by Springer Nature
- p. 229-239
Research on Temperature Monitoring of New Energy Ship Engines Based on Sapphire Fiber Fabry-Perot High-Temperature Sensing Technology
- 11 February 2026
- Published by Springer Nature
- p. 229-239
Research on Temperature Monitoring of New Energy Ship Engines Based on Sapphire Fiber Fabry-Perot High-Temperature Sensing Technology
- 31 May 2024
- Published by Elsevier in Environmental Pollution
- Vol. 356, 124292
Application of improved machine learning in large-scale investigation of plastic waste distribution in tourism Intensive artificial coastlines
- 31 May 2024
- Published by Elsevier in Environmental Pollution
- Vol. 356, 124292
Application of improved machine learning in large-scale investigation of plastic waste distribution in tourism Intensive artificial coastlines
- Open Access
- 16 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 13 (3) , 1-10
Mechanical Filter-Based Differential Pressure Fiber-Optic Fabry-Perot Infrasound Sensor
A differential pressure fiber optic infrasound sensor based on a mechanical filter was developed, for the detection of infrasound within the frequency range of 0.01--1 Hz. The sensing unit employs a miniature polyphenylene sulfide (PPS) diaphragm which is fixed onto a glass ferrule. An extrinsic Fabry-Perot (F-P) interferometer was fabricated between the optical fiber end face and the PPS diaphragm, and a mechanical filter structure introduced to improve the minimum detectable frequency down to 0.005 Hz. Experimental results indicate that this infrasound sensor shows a favorable frequency response for infrasound signals between 0.01 and 1 Hz, and it exhibits an average minimum detectable pressure (MDP) of 88.85 mPa·Hz −1/2 . Our platform provides a promising solution for sensors in infrasound signal detection applications.
- 16 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 13 (3) , 1-10
Open AccessMechanical Filter-Based Differential Pressure Fiber-Optic Fabry-Perot Infrasound Sensor
A differential pressure fiber optic infrasound sensor based on a mechanical filter was developed, for the detection of infrasound within the frequency range of 0.01--1 Hz. The sensing unit employs a miniature polyphenylene sulfide (PPS) diaphragm which is fixed onto a glass ferrule. An extrinsic Fabry-Perot (F-P) interferometer was fabricated between the optical fiber end face and the PPS diaphragm, and a mechanical filter structure introduced to improve the minimum detectable frequency down to 0.005 Hz. Experimental results indicate that this infrasound sensor shows a favorable frequency response for infrasound signals between 0.01 and 1 Hz, and it exhibits an average minimum detectable pressure (MDP) of 88.85 mPa·Hz −1/2 . Our platform provides a promising solution for sensors in infrasound signal detection applications.
- 25 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 39 (12) , 3911-3918
Hybrid Sapphire Dual-Fabry—Perot-Cavities Sensor for High Temperature and Refractive Index Measurement
We presented a hybrid sapphire dual-Fabry-Perot-cavities sensor for high temperature and refractive index measurement. A double-sided polished sapphire solid wafer is connected in series with a double-sided parallel sapphire C-ring and a single-sided polished sapphire mirror to form the hybrid Fabry-Perot interferometer. The double-sided polished sapphire solid wafer acts as the first Fabry-Perot cavity for temperature sensing, and the sapphire hollow C-ring cavity constitutes the second Fabry-Perot cavity for measuring the refractive index of external environment medium. The single-sided polished sapphire mirror serves as the most distal reflector. Heterogeneous fiber splicing between sapphire fiber and multimode silica fiber is realized to achieve long-distance transmission of interference signals. A series of high temperature measurement experiments range of room temperature to 1080°C in an air environment and refractive index measurement experiments in a liquid environment were carried out. The refractive index and temperature sensitivities were ${2.0659 \times 10^{5}}$ nm/RIU in the RI range of 1.3330~1.3741 and 7.837nm/°C at 1080°C.- 25 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 39 (12) , 3911-3918
Hybrid Sapphire Dual-Fabry—Perot-Cavities Sensor for High Temperature and Refractive Index Measurement
We presented a hybrid sapphire dual-Fabry-Perot-cavities sensor for high temperature and refractive index measurement. A double-sided polished sapphire solid wafer is connected in series with a double-sided parallel sapphire C-ring and a single-sided polished sapphire mirror to form the hybrid Fabry-Perot interferometer. The double-sided polished sapphire solid wafer acts as the first Fabry-Perot cavity for temperature sensing, and the sapphire hollow C-ring cavity constitutes the second Fabry-Perot cavity for measuring the refractive index of external environment medium. The single-sided polished sapphire mirror serves as the most distal reflector. Heterogeneous fiber splicing between sapphire fiber and multimode silica fiber is realized to achieve long-distance transmission of interference signals. A series of high temperature measurement experiments range of room temperature to 1080°C in an air environment and refractive index measurement experiments in a liquid environment were carried out. The refractive index and temperature sensitivities were ${2.0659 \times 10^{5}}$ nm/RIU in the RI range of 1.3330~1.3741 and 7.837nm/°C at 1080°C.- 14 October 2020
- Published by Optica Publishing Group in Applied Optics
- Vol. 59 (30) , 9353-9358
High-consistency fiber-optic Fabry–Perot sensor based on MEMS for simultaneous temperature and liquid refractive index measurement
We proposed a hybrid Fabry–Perot fiber-optic sensor based on the microelectromechanical system (MEMS) technique for measuring temperature and liquid refractive index simultaneously, and we verify the consistency of four sensors in the same batch. The sensor consists of a groove-array structured glass wafer and two silicon wafers, which are connected by double-sided anodic bonding. The three parts form two independent Fabry–Perot cavities for temperature and liquid refractive index sensing, respectively. We randomly selected three sensors in the same batch and conducted temperature and refractive index experiments to establish the sensing equation. The experimental results demonstrate their high consistency with temperature sensitivities of 81.6, 81.8, and 81.4 pm/°C in the range of 10°C to 80°C, and refractive index sensitivities of 1040.11, 1044.24, 1042.91 nm/RIU in the range of 1.333 − 1.374 . The sensors have low cross-sensitivities that are less than 5.86 × 10 − 6 RIU/°C and high precisions of 0.047°C, 2.14 × 10 − 6 R I U , respectively. To verify the validity of the sensing equation, we made another sensor in the same batch and got maximum errors of 0.36°C and 7.7 × 10 − 5 R I U , respectively.
- 14 October 2020
- Published by Optica Publishing Group in Applied Optics
- Vol. 59 (30) , 9353-9358
High-consistency fiber-optic Fabry–Perot sensor based on MEMS for simultaneous temperature and liquid refractive index measurement
We proposed a hybrid Fabry–Perot fiber-optic sensor based on the microelectromechanical system (MEMS) technique for measuring temperature and liquid refractive index simultaneously, and we verify the consistency of four sensors in the same batch. The sensor consists of a groove-array structured glass wafer and two silicon wafers, which are connected by double-sided anodic bonding. The three parts form two independent Fabry–Perot cavities for temperature and liquid refractive index sensing, respectively. We randomly selected three sensors in the same batch and conducted temperature and refractive index experiments to establish the sensing equation. The experimental results demonstrate their high consistency with temperature sensitivities of 81.6, 81.8, and 81.4 pm/°C in the range of 10°C to 80°C, and refractive index sensitivities of 1040.11, 1044.24, 1042.91 nm/RIU in the range of 1.333 − 1.374 . The sensors have low cross-sensitivities that are less than 5.86 × 10 − 6 RIU/°C and high precisions of 0.047°C, 2.14 × 10 − 6 R I U , respectively. To verify the validity of the sensing equation, we made another sensor in the same batch and got maximum errors of 0.36°C and 7.7 × 10 − 5 R I U , respectively.
- 29 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 39 (12) , 4013-4019
Ultrasensitive Label-Free Biosensor Based on the Graphene-Oxide-Coated-U-Bent Long-Period Fiber Grating Inscribed in a Two-Mode Fiber
In this paper, we theoretically and experimentally report a newly-designed biosensor, which consists of a particular graphene-oxide (GO)-coated-U-bent long-period fiber grating inscribed in a two-mode fiber (LPFG-TMF). Due to the enhancement of evanescent field, the bent LPFG-TMF is more sensitive to the surrounding refractive index and it allows an extremely high sensitivity. The impact of bent radius on the sensing performance is discussed. The experimental result demonstrates the sensitivity increases nonlinearly with the surrounding refractive index, and the highest sensitivity reaches 6632.32 nm/RIU in the refractive index region from 1.3731 to 1.3830. To optimize the immune-sensing performance, the goat anti-human IgG is immobilized on the sensor via covalent bond through EDC/NHS cross-linker for human IgG recognition. The GO-coated-U-bent LPFG-TMF with bent radius of 15 mm has gained a low limit of detection (23 ng/ml) in the 3-20 g/ml. In addition, the repeatability of the sensor is also investigated. With its premium ability of easy fabrication, high sensitivity, and compactness, the proposed sensor is adapted for detection of human IgG in clinical diagnostics, pharmaceutical researches, and bioengineering applications.
- 29 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 39 (12) , 4013-4019
Ultrasensitive Label-Free Biosensor Based on the Graphene-Oxide-Coated-U-Bent Long-Period Fiber Grating Inscribed in a Two-Mode Fiber
In this paper, we theoretically and experimentally report a newly-designed biosensor, which consists of a particular graphene-oxide (GO)-coated-U-bent long-period fiber grating inscribed in a two-mode fiber (LPFG-TMF). Due to the enhancement of evanescent field, the bent LPFG-TMF is more sensitive to the surrounding refractive index and it allows an extremely high sensitivity. The impact of bent radius on the sensing performance is discussed. The experimental result demonstrates the sensitivity increases nonlinearly with the surrounding refractive index, and the highest sensitivity reaches 6632.32 nm/RIU in the refractive index region from 1.3731 to 1.3830. To optimize the immune-sensing performance, the goat anti-human IgG is immobilized on the sensor via covalent bond through EDC/NHS cross-linker for human IgG recognition. The GO-coated-U-bent LPFG-TMF with bent radius of 15 mm has gained a low limit of detection (23 ng/ml) in the 3-20 g/ml. In addition, the repeatability of the sensor is also investigated. With its premium ability of easy fabrication, high sensitivity, and compactness, the proposed sensor is adapted for detection of human IgG in clinical diagnostics, pharmaceutical researches, and bioengineering applications.
- 23 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 37 (4) , 1408-1414
Self-Filtering High-Resolution Dual-Sapphire-Fiber-Based High-Temperature Sensor
We present a self-filtering and high-resolution sapphire fiber sensor based on an extrinsic Fabry-Pérot interferometer for high-temperature sensing. The sensor has a high fringe visibility and signal-to-noise ratio. Two well-polished sapphire fibers are aligned side by side to realize shunting transmission between the background light and the interference signal. Heterogeneous fiber splicing between the sapphire fiber and the multimode silica fiber is realized for long-distance transmission of signals. A C-plane double-sided polished sapphire wafer is mounted perpendicularly to the tip of sapphire fibers as the Fabry-Pérot cavity. The crosstalk noise from input light caused by heterogeneous fiber splicing and fiber tip reflection is filtered out to reach a higher signal quality. A series of comparison experiments from 100 to 1080 °C were carried out for the difference in characteristics between self-filtering sensors and traditional sapphire fiber Fabry-Pérot sensors. The self-filtering sensor's fringe visibility was above 43.96%, and its signal-to-noise ratio was above 20.14 dB. The temperature resolution of the self-filtering sensor was better than 0.25 °C.
- 23 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 37 (4) , 1408-1414
Self-Filtering High-Resolution Dual-Sapphire-Fiber-Based High-Temperature Sensor
We present a self-filtering and high-resolution sapphire fiber sensor based on an extrinsic Fabry-Pérot interferometer for high-temperature sensing. The sensor has a high fringe visibility and signal-to-noise ratio. Two well-polished sapphire fibers are aligned side by side to realize shunting transmission between the background light and the interference signal. Heterogeneous fiber splicing between the sapphire fiber and the multimode silica fiber is realized for long-distance transmission of signals. A C-plane double-sided polished sapphire wafer is mounted perpendicularly to the tip of sapphire fibers as the Fabry-Pérot cavity. The crosstalk noise from input light caused by heterogeneous fiber splicing and fiber tip reflection is filtered out to reach a higher signal quality. A series of comparison experiments from 100 to 1080 °C were carried out for the difference in characteristics between self-filtering sensors and traditional sapphire fiber Fabry-Pérot sensors. The self-filtering sensor's fringe visibility was above 43.96%, and its signal-to-noise ratio was above 20.14 dB. The temperature resolution of the self-filtering sensor was better than 0.25 °C.