Peter C. Raffalt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Peter C. Raffalt has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Tine Alkjær
Department of Biomedical Sciences, University of Copenhagen, 2200 Copenhagen N, Denmark
3 shared publications Jacob Wienecke
Department of Nutrition, Exercise and Sports, University of Copenhagen, Copenhagen, Denmark
2 shared publications- Jens Bo Nielsen
University of Copenhagen
2 shared publications - Jessica Pingel
Department of Neuroscience, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
2 shared publications - Laurits Munk Højberg
Department of Nutrition, Exercise and Sports, University of Copenhagen, Copenhagen, Denmark
2 shared publications Louise R. Nielsen
Center of Neuroscience, University of Copenhagen, Copenhagen, Denmark
2 shared publications
Latest Publications
- 1 October 2019
- Published by Elsevier in Human Movement Science
- Vol. 67, 102462
Dynamics of postural control during bilateral stance – Effect of support area, visual input and age
- 1 October 2019
- Published by Elsevier in Human Movement Science
- Vol. 67, 102462
Dynamics of postural control during bilateral stance – Effect of support area, visual input and age
- 1 July 2019
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 110, 120-126
Dynamics of postural control in individuals with ankle instability: Effect of visual input and orthotic use
- 1 July 2019
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 110, 120-126
Dynamics of postural control in individuals with ankle instability: Effect of visual input and orthotic use
- Open Access
On the Calculation of Sample Entropy Using Continuous and Discrete Human Gait Data
Sample entropy (SE) has relative consistency using biologically-derived, discrete data >500 data points. For certain populations, collecting this quantity is not feasible and continuous data has been used. The effect of using continuous versus discrete data on SE is unknown, nor are the relative effects of sampling rate and input parameters m (comparison vector length) and r (tolerance). Eleven subjects walked for 10-minutes and continuous joint angles (480 Hz) were calculated for each lower-extremity joint. Data were downsampled (240, 120, 60 Hz) and discrete range-of-motion was calculated. SE was quantified for angles and range-of-motion at all sampling rates and multiple combinations of parameters. A differential relationship between joints was observed between range-of-motion and joint angles. Range-of-motion SE showed no difference; whereas, joint angle SE significantly decreased from ankle to knee to hip. To confirm findings from biological data, continuous signals with manipulations to frequency, amplitude, and both were generated and underwent similar analysis to the biological data. In general, changes to m, r, and sampling rate had a greater effect on continuous compared to discrete data. Discrete data was robust to sampling rate and m. It is recommended that different data types not be compared and discrete data be used for SE.
Open AccessOn the Calculation of Sample Entropy Using Continuous and Discrete Human Gait Data
Sample entropy (SE) has relative consistency using biologically-derived, discrete data >500 data points. For certain populations, collecting this quantity is not feasible and continuous data has been used. The effect of using continuous versus discrete data on SE is unknown, nor are the relative effects of sampling rate and input parameters m (comparison vector length) and r (tolerance). Eleven subjects walked for 10-minutes and continuous joint angles (480 Hz) were calculated for each lower-extremity joint. Data were downsampled (240, 120, 60 Hz) and discrete range-of-motion was calculated. SE was quantified for angles and range-of-motion at all sampling rates and multiple combinations of parameters. A differential relationship between joints was observed between range-of-motion and joint angles. Range-of-motion SE showed no difference; whereas, joint angle SE significantly decreased from ankle to knee to hip. To confirm findings from biological data, continuous signals with manipulations to frequency, amplitude, and both were generated and underwent similar analysis to the biological data. In general, changes to m, r, and sampling rate had a greater effect on continuous compared to discrete data. Discrete data was robust to sampling rate and m. It is recommended that different data types not be compared and discrete data be used for SE.
- 25 September 2018
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 140 (12)
Day-to-Day Reliability of Nonlinear Methods to Assess Walking Dynamics
The present study investigated the day-to-day reliability (quantified by the absolute and relative reliability) of nonlinear methods used to assess human locomotion dynamics. Twenty-four participants of whom twelve were diagnosed with knee osteoarthritis completed 5 min of treadmill walking at self-selected preferred speed on two separate days. Lower limb kinematics were recorded at 100 Hz and hip, knee, and ankle joint angles, three-dimensional (3D) sacrum marker displacement and stride time intervals were extracted for 170 consecutive strides. The largest Lyapunov exponent and correlation dimension were calculated for the joint angle and sacrum displacement data using three different state space reconstruction methods (group average, test-retest average, individual time delay and embedding dimension). Sample entropy and detrended fluctuation analysis (DFA) were applied to the stride time interval time series. Relative reliability was assessed using intraclass correlation coefficients and absolute reliability was determined using measurement error (ME). For both joint angles and sacrum displacement, there was a general pattern that the group average state space reconstruction method provided the highest relative reliability and lowest ME compared to the individual and test-retest average methods. The DFA exhibited good reliability, while the sample entropy showed poor reliability. The results comprise a reference material that can inspire and guide future studies of nonlinear gait dynamics.
- 25 September 2018
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 140 (12)
Day-to-Day Reliability of Nonlinear Methods to Assess Walking Dynamics
The present study investigated the day-to-day reliability (quantified by the absolute and relative reliability) of nonlinear methods used to assess human locomotion dynamics. Twenty-four participants of whom twelve were diagnosed with knee osteoarthritis completed 5 min of treadmill walking at self-selected preferred speed on two separate days. Lower limb kinematics were recorded at 100 Hz and hip, knee, and ankle joint angles, three-dimensional (3D) sacrum marker displacement and stride time intervals were extracted for 170 consecutive strides. The largest Lyapunov exponent and correlation dimension were calculated for the joint angle and sacrum displacement data using three different state space reconstruction methods (group average, test-retest average, individual time delay and embedding dimension). Sample entropy and detrended fluctuation analysis (DFA) were applied to the stride time interval time series. Relative reliability was assessed using intraclass correlation coefficients and absolute reliability was determined using measurement error (ME). For both joint angles and sacrum displacement, there was a general pattern that the group average state space reconstruction method provided the highest relative reliability and lowest ME compared to the individual and test-retest average methods. The DFA exhibited good reliability, while the sample entropy showed poor reliability. The results comprise a reference material that can inspire and guide future studies of nonlinear gait dynamics.
- 17 May 2018
- Published by Elsevier in Journal of Biomechanics
- Vol. 73, 168-176
Assessment of intersegmental coordination of rats during walking at different speeds - Application of continuous relative phase
- 17 May 2018
- Published by Elsevier in Journal of Biomechanics
- Vol. 73, 168-176
Assessment of intersegmental coordination of rats during walking at different speeds - Application of continuous relative phase
- 1 April 2018
- Published by Elsevier in Journal of Biomechanics
- Vol. 72, 247-251
Day-to-day reliability of gait characteristics in rats
- 1 April 2018
- Published by Elsevier in Journal of Biomechanics
- Vol. 72, 247-251
Day-to-day reliability of gait characteristics in rats