LMLindsay J. Ma

Lindsay J. Ma

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Lindsay J. Ma has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Assessing the Role of Medical Caption Technology to Support Physician-Patient Communication for Patients With Hearing Loss: Mixed Methods Pilot Study

    by Sarah E Hughes, Liang-Yuan Wu, Lindsay J Ma, Dhruv Jain, Michael M McKee

    Background: Speech recognition technology is widely used by individuals who are Deaf/deaf and hard-of-hearing (DHH) in everyday communication, but its clinical applications remain underexplored. Communication barriers in health care can compromise safety, understanding, and autonomy for individuals who are DHH. Objective: This study aimed to evaluate a real-time speech recognition system (SRS) tailored for clinical settings, examining its usability, perceived effectiveness, and transcription accuracy among users who are DHH. Methods: We conducted a pilot study with 10 adults who are DHH participating in mock outpatient encounters using a custom SRS powered by Google’s speech-to-text application programming interface. We used a convergent parallel mixed-methods design, collecting quantitative usability ratings and qualitative interview data during the same study session. These datasets were subsequently merged and jointly interpreted. Participants completed postscenario surveys and structured exit interviews assessing distraction, trust, ease of use, satisfaction, and emotional response. Caption accuracy was benchmarked against professional communication access real-time translation transcripts using word error rate (WER). Because WER assigns equal weight to all tokens, it does not differentiate between routine transcription errors and those involving safety-critical clinical terms (eg, medications or diagnoses). Therefore, WER may underestimate the potential impact of certain errors in medical contexts. Results: Across 29 clinical scenario simulations, 86% (25/29) of participants found captions nondistracting, 90% (26/29) reported them easy to follow and trustworthy, and 76% (22/29) were satisfied with the experience. Participants described the SRS as intuitive, emotionally grounding, and preferable to lip reading in masked settings. WER ranged from 12.7% to 22.8%, consistent with benchmarks for automated SRSs. Interviews revealed themes of increased confidence in following clinical conversations and staying engaged despite masked communication. Participants reported less anxiety about missing critical medical information and expressed a strong interest in expanding the tool to real-world settings, especially for older adults or those with cognitive impairments. Conclusions: Our findings support the potential of real-time captioning to enhance accessibility and reduce the cognitive and mental burden of communication for individuals who are DHH in clinical care. Participants described the SRS as both functionally effective and personally empowering. While accuracy for complex medical terminology remains a limitation, participants consistently expressed trust in the system and a desire for its integration into clinical care. Future research should explore real-world implementation, domain-specific optimization, and the development of user-centered evaluation metrics that extend beyond transcription fidelity to include trust, autonomy, and communication equity.


  • Open Access

    Assessing the Role of Medical Caption Technology to Support Physician-Patient Communication for Patients with Hearing Loss: A Pilot Study (Preprint)

    by Sarah E Hughes, Liang-Yuan Wu, Lindsay J Ma, Dhruv Jain, Michael M McKee

    BACKGROUND Speech recognition technology is widely used by D/deaf and hard-of-hearing (DHH) individuals in everyday communication, but its clinical applications remain underexplored. Communication barriers in healthcare can compromise safety, understanding, and autonomy for DHH individuals. OBJECTIVE This study evaluated a real-time speech recognition system (SRS) tailored for clinical settings, examining its usability, perceived effectiveness, and transcription accuracy among DHH users. METHODS We conducted a pilot study with 10 DHH adults participating in mock outpatient encounters using a custom SRS powered by Google’s speech-to-text API. Participants completed post-scenario surveys and structured exit interviews assessing distraction, trust, ease of use, satisfaction, and emotional response. Caption accuracy was benchmarked against professional Communication Access Realtime Translation (CART) transcripts using word error rate (WER). RESULTS Across 29 clinical scenario simulations, 86% of participants found captions non-distracting, 90% reported them easy to follow and trustworthy, and 76% were satisfied with the experience. Participants described the SRS as intuitive, emotionally grounding, and preferable to lipreading in masked settings. WER ranged from 12.7% to 22.8%, consistent with benchmarks for automated speech recognition systems. Interviews revealed themes of increased confidence in following clinical conversations and staying engaged despite masked communication, reduced anxieties about missing critical medical information, and strong interest in expanding the tool to real-world settings, especially for older adults or those with cognitive impairments. CONCLUSIONS Our findings support the potential of real-time captioning to enhance accessibility and reduce the cognitive and mental burden of communication for DHH individuals in clinical care. Participants described the SRS as both functionally effective and personally empowering. While accuracy for complex medical terminology remains a limitation, participants consistently expressed trust in the system and a desire for its integration into clinical care. Future research should explore real-world implementation, domain-specific optimization, and the development of user-centered evaluation metrics that extend beyond transcription fidelity to include trust, autonomy, and communication equity. CLINICALTRIAL N/A

  • Transcript Accuracy in Preclinical Medical School Lectures

    by Lindsay J. Ma, Jawad Al-Khafaji, Stephanie P. Taylor, Christopher Grondin

    Medical students acquire knowledge in the preclinical phase primarily through didactic lectures. Lectures are commonly delivered via video recordings and include transcripts and/or closed captions. Transcript accuracy may improve or worsen student perceptions of equity and accessibility in education, but data quantifying or otherwise exploring transcript errors in medical student education is scarce. First-year preclinical medical students were surveyed. The semi-structured survey consisted of yes/no questions, slider type questions, 5-point Likert scales, and an open-ended question to assess usage of transcripts while watching lectures and perceptions of transcript errors. Survey data were interpreted using univariate analyses and inductive open coding. The authors also audited lectures for accuracy of transcripts. Two-sample t-tests were performed to compare transcript error rates. Quantitative survey results from 85 students revealed that 94% of participants used transcripts when consuming lectures, 96% noticed errors, and 59% felt that errors negatively impacted their learning. An audit of 36 lectures from two curricular blocks revealed that transcript accuracy failed to meet industry standards (i.e., ≥ 99% accuracy) in 35% of clinical science lectures (e.g., the diagnosis/management of diseases) and 5% of basic science lectures (e.g., biochemistry). Although medical students rely on accurate transcripts of didactic lectures for both accessibility and facilitation of learning, current lecture transcripts fail to consistently meet industry standards for accuracy and correlate with student dissatisfaction. Given medical schools deliver much of their lectures as video recordings, these findings represent an important gap in need of future study. The online version contains supplementary material available at 10.1007/s40670-025-02301-2.


  • Open Access

    A Parametric Analysis of Capillary Height in Single-Layer, Small-Scale Microfluidic Artificial Lungs

    by Lindsay J. Ma, Emmanuel A. Akor, Alex J. Thompson, Joseph A. Potkay

    Microfluidic artificial lungs (μALs) are being investigated for their ability to closely mimic the size scale and cellular environment of natural lungs. Researchers have developed μALs with small artificial capillary diameters (10–50 µm; to increase gas exchange efficiency) and with large capillary diameters (~100 µm; to simplify design and construction). However, no study has directly investigated the impact of capillary height on μAL properties. Here, we use Murray’s law and the Hagen-Poiseuille equation to design single-layer, small-scale μALs with capillary heights between 10 and 100 µm. Each µAL contained two blood channel types: capillaries for gas exchange; and distribution channels for delivering blood to/from capillaries. Three designs with capillary heights of 30, 60, and 100 µm were chosen for further modeling, implementation and testing with blood. Flow simulations were used to validate and ensure equal pressures. Designs were fabricated using soft lithography. Gas exchange and pressure drop were tested using whole bovine blood. All three designs exhibited similar pressure drops and gas exchange; however, the μAL with 60 µm tall capillaries had a significantly higher wall shear rate (although physiologic), smaller priming volume and smaller total blood contacting surface area than the 30 and 100 µm designs. Future μAL designs may need to consider the impact of capillary height when optimizing performance.


  • Barriers to colorectal cancer screening in Ghana: a qualitative study of patients and physicians

    by A. Lussiez, C. K. Dally, E. A. Boateng, K. Bosompem, E. Peprah, L. Hayward, L. Janes, M. Byrnes, A. Vitous, A. Duby, et al.

    Purpose The incidence of colorectal cancer (CRC) in Ghana has increased eightfold since the 1960s. In 2011, national guidelines were set forth recommending all patients aged 50–70 years old undergo annual CRC screening with fecal occult blood testing (FOBT), but adherence to these guidelines is poor and screening rates remain low for unclear reasons. Methods We performed semi-structured interviews with 28 Ghanaians including physicians (n = 14) and patients (n = 14) from the Komfo Anokye Teaching Hospital in Kumasi, Ghana, to better understand the factors driving screening adherence and perceived barriers identified in an earlier quantitative study. Results Participants reported sociocultural factors such as reliance on alternative medicine or religion, lack of education, and financial burden as community-level barriers to CRC screening. At the system level, screening was limited by insufficient access to FOBT as well as a perceived lack of national prioritization. This was described as inadequate efforts from the Ministry of Health regarding national education as well as lack of incorporation of CRC screening into the National Health Insurance Scheme. Conclusion Several community- and system-level barriers exist to widespread screening of CRC in Ghana. A multi-level approach will be required to improve rates of CRC screening and ultimately reduce the burden of CRC in Ghana.


  • Design Analysis and Optimization of a Single-Layer PDMS Microfluidic Artificial Lung

    by Alex J. Thompson, Lindsay J. Ma, Thomas J. Plegue, Joseph A. Potkay

    Objective: Microfluidic artificial lungs (μALs) are being researched for future clinical use due to the potential for increased gas exchange efficiency, small blood contacting surface area, small priming volume, and biomimetic blood flow paths. However, a current roadblock to clinical use is the need to stack hundreds to thousands of these small-scale μALs in parallel to reach clinically relevant blood flows. The need for so many layers not only increases the complexity and projected cost to manufacture a μAL, but also could result in devices which are cumbersome, and, therefore, not suitable for portable artificial lung systems. Methods: Here, we describe the design analysis and optimization of a single-layer μAL that simultaneously calculates rated blood flow, blood contacting surface area, blood volume, pressure drop, and shear stress as a function of blood channel height using previously developed closed-form mathematical equations. A μAL designed using this procedure is then implemented and tested. Results: The resulting device exhibits a rated flow of 17 mL/min and reduces the number of layers required for clinically relevant μAL devices by a factor of up to 32X compared to previous work. Conclusion: This procedure could significantly reduce manufacturing complexity as well as eliminate a barrier to the clinical application of these promising devices. Significance: The described method results in the highest rated flow for any single-layer μAL to date.