    Quantitative spatial analysis of crystallin proteins in human lens epithelial cells

    by Alessandro Cristoforetti, Giorgio Baldessari, Lizaveta Chychko, Ignacio Babiloni Chust, Samuele Sartori, Sonja Schickhardt, Flavia Ravelli, Silvia Bertoluzza, Matthias Carl, Saadettin Sel, et al.

    Resolving spatial protein dynamics in native human epithelial tissues presents a significant technical challenge, particularly in inherently curved or unevenly mounted specimens. Here, we introduce an image processing pipeline for high-resolution, compartment-based analysis of protein localization, using the native three-dimensional architecture of the human anterior lens epithelium and capsule complex as a robust ex vivo proof-of-principle platform for precise cell segmentation and quantitative analysis. This platform integrates whole-mount immunostaining, 3D confocal imaging, computational tissue flattening, digital segmentation, and spatial regression to quantitatively map subcellular protein distributions at the tissue scale. To demonstrate the utility of this approach, we examined the spatial distribution of αB-crystallin (CRYAB), a stress-associated small heat shock protein, and βB2-crystallin (CRYBB2), a predominantly structural lens protein, in specimens obtained during cataract surgery. We observed a marked accumulation of CRYAB in epithelial cells at the capsule edge following both laser and manual capsulorhexis, indicating a localized stress response to surgical intervention. In contrast, CRYBB2 distribution remained unaffected. Furthermore, both proteins exhibited consistent cytoplasmic localization, while only CRYBB2 occasionally showed exclusive nuclear accumulation. This pipeline offers a scalable framework for quantitatively resolving protein localization in native epithelial architectures, using CRYAB and CRYBB2 as examples of how stress-associated changes can be spatially mapped in situ within the human lens.

  • Open Access

    Hybrid Ablation in Atrial Fibrillation: Bridging Mechanistic Understanding and Clinical Practice

    by Flavia Ravelli, Stefano Branzoli, Alessandro Cristoforetti, Silvia Quintarelli, Alessio Coser, Paolo Moggio, Mark La Meir, Carlo de Asmundis, Luigi Pannone, Francesco Onorati, et al.

    Atrial fibrillation (AF), the most prevalent sustained cardiac arrhythmia, poses a significant burden on global morbidity and healthcare expenditure. Although endocardial catheter ablation and surgical ablation are established therapeutic strategies, each exhibits inherent limitations in achieving comprehensive substrate modification. Hybrid ablation therapy, integrating both endocardial and epicardial approaches, aims to overcome these limitations by enabling the more extensive and transmural targeting of arrhythmogenic foci and the complex atrial substrate. This review synthesizes the electrophysiological basis and mechanistic rationale underpinning hybrid AF ablation, highlighting its potential for an enhanced efficacy compared to isolated techniques. Furthermore, it introduces the emerging paradigm of three-dimensional ablation within this evolving field.

  • Open Access

    Robust Collagen Texture Quantification in Nonlinear Microscopy by Combining the Gradient Structure Tensor With a Mixed Noise Model

    by Alessandro Cristoforetti, Michela Masè, Francesco Tessarolo, Flavia Ravelli

    Collagen structure derangement is a hallmark of several diseases in different types of tissue. Extraction of quantitative markers of collagen organization from nonlinear microscopy images can help early disease detection, but it can be affected by the presence of image noise. This study introduced and validated a novel methodology for a robust quantification of collagen fiber direction, dispersion, and degree of anisotropy (DA) from collagen images, based on the reinforcement of the gradient structure tensor computation with a mixed noise model. The method was validated on a synthetic image dataset, generated by a vector field-based fiber generator algorithm, assessing its capability to distinguish different fiber organization levels and its robustness against increasing levels of image noise. The method showed an accurate estimation of fiber angle direction with errors < 2 deg for a signal-to-noise ratio (SNR) down to 5, and a slight underestimation of angle variability in the presence of fiber scales smaller than the tensor radius. Local and global DA were able to distinguish different degrees of fiber organization even at high noise level (SNR=5), with small accuracy errors for the local (<0.04) and global (<0.06) DA at realistic patterns. Proof-of-concept application of the method to human cardiac samples suggested its potential in distinguishing different collagen organization levels in real tissues. The method may represent a useful tool for the investigation of collagen structural remodeling in a variety of fibrosis-related pathological conditions. Future studies should address the method tuning to specific tissues, diseases, and clinical problems.


  • Open Access

    Systematic in-silico evaluation of fibrosis effects on re-entrant wave dynamics in atrial tissue

    by Michela Masè, Alessandro Cristoforetti, Samuele Pelloni, Flavia Ravelli

    Despite the key role of fibrosis in atrial fibrillation (AF), the effects of different spatial distributions and textures of fibrosis on wave propagation mechanisms in AF are not fully understood. To clarify these aspects, we performed a systematic computational study to assess fibrosis effects on the characteristics and stability of re-entrant waves in electrically-remodelled atrial tissues. A stochastic algorithm, which generated fibrotic distributions with controlled overall amount, average size, and orientation of fibrosis elements, was implemented on a monolayer spheric atrial model. 245 simulations were run at changing fibrosis parameters. The emerging propagation patterns were quantified in terms of rate, regularity, and coupling by frequency-domain analysis of correspondent synthetic bipolar electrograms. At the increase of fibrosis amount, the rate of reentrant waves significantly decreased and higher levels of regularity and coupling were observed (p < 0.0001). Higher spatial variability and pattern stochasticity over repetitions was observed for larger amount of fibrosis, especially in the presence of patchy and compact fibrosis. Overall, propagation slowing and organization led to higher stability of re-entrant waves. These results strengthen the evidence that the amount and spatial distribution of fibrosis concur in dictating re-entry dynamics in remodeled tissue and represent key factors in AF maintenance.


  • Open Access

    Measuring Total Filtration Efficiency of Surgical and Community Face Masks: Impact of Mask Design Features

    by Silvia Chiera, Alessandro Cristoforetti, Luca Benedetti, Luca Borro, Lorenzo Mazzei, Giandomenico Nollo, Alessio Bucciarelli, Francesco Tessarolo

    Surgical and community face masks are used worldwide to reduce the transmission of respiratory infections in indoor environments. Performance parameters for these loose-fitting devices are mainly focused on material filtering efficiency, while, differently from face respirators, there are no standards methods for measuring the fraction of air leaking at the face seal. This study quantifies the total filtration efficiency (TFE), a parameter based both on filter efficiency and air leakage, of 50 face mask models with the aim of understanding the role of several mask design features on TFE performance. An instrumented head form equipped with sensors for measuring volumetric airflow and differential pressure was used to simulate the air exhalation from the mouth of a person wearing a face mask. A Response Surface Method (RSM) was used to model the TFE experimental data. Results showed that TFE values ranged over a wide interval (from 5 % to 73 %), with better values at higher flowrates. A significant positive correlation was found between TFE and filter breathability. The presence of a nosepiece showed to increase the TFE on average from 4 % to 6 %, according to the flowrate. Significant improvements were associated only to nosepieces incorporating a metallic wire. The RSM model evidenced that the increase in the number of the filter layers, and the use of a meltblown layer, result in higher TFE only when a nosepiece is in place. Differently, the benefit of the nosepiece is less marked for masks made of highly breathable filters. To improve overall mask performance, the design of loose-fitting face masks should carefully compromise between breathability and filtration efficiency of the filter materials. The addition of a metallic nosepiece help improving the TFE by limiting the air leaking at the face seal.


  • Open Access

    Model-Based Approach for the Semi-Automatic Analysis of Collagen Birefringence in Polarized Light Microscopy

    by Alessandro Cristoforetti, Michela Masè, Flavia Ravelli

    Collagen is a key determinant of physio-pathological processes in different tissues. Polarization light microscopy (PLM) of histological sections is the gold-standard for birefringence-based collagen quantification, but post-session image analysis can be time-consuming and subjective. We propose an efficient semi-automatic computational approach for the quantification of collagen content from the analysis of PLM images of birefringent histological sections. The method is based on a physical model of light-sample interaction and birefringence effect production. It combines the information of bright and dark-field PLM images to segment the luminal region and detect the birefringent signal associated with collagen in the tissue region. User input is limited to the selection of a threshold on an image subset and the supervision of the processing, enabling fast analysis of large datasets. Modeling of the birefringence signal compensates for variability factors related to sample processing and image acquisition, such as section thickness variability and nonuniform illumination and transmittance. As a proof-of-concept, the method was applied to human cardiac tissue PLM images, acquired in 14 cardiac surgery patients with different arrhythmic profiles. The method was able to detect a significantly larger amount and higher heterogeneity of fibrosis in the atrium of patients with as opposed to without atrial fibrillation (p < 0.05). The proposed method can be a valid aid to quicken and reinforce the analysis of large sets of PLM images for the quantification of collagen distribution in different tissues and pathologies.


  • Open Access

    Accuracy and Technical Predictability of Computer Guided Bone Harvesting from the Mandible: A Cone-Beam CT Analysis in 22 Consecutive Patients

    by Luca De Stavola, Alessandro Cristoforetti, Andrea Fincato, Giandomenico Nollo, Paolo Ghensi, Anna Cantarutti, Francesco Tessarolo

    This study assesses the accuracy and technical predictability of a computer-guided procedure for harvesting bone from the external oblique ridge using a patient-specific cutting guide. Twenty-two patients needing bone augmentation for implant placement were subjected to mandibular osteotomy employing a case-specific stereolithographic surgical guide generated through computer aided design. Differences between planned and real cut planes were measured comparing pre- and post-operative Cone Beam Computed Tomography images of the donor site according to six validated angular and displacement indexes. Accuracy and technical predictability were assessed for 119 osteotomy planes over the study population. Three different guide fitting approaches were compared. An average root-mean-square discrepancy of 0.52 (0.30–0.97) mm was detected. The accuracy of apical and medial planes was higher than the mesial and distal planes due to occasional antero-posterior guide shift. Fitting the guide with an extra reference point on the closest tooth performed better than using only the bone surface, with two indexes significantly lower and less disperse. The study showed that the surgical plan was actualized with a 1 mm safety margin, allowing effective nerve preservation and reducing technical variability. When possible, surgical guide design should allow fitting on the closest tooth based on both radiological and/or intra-oral scan data.


  • Open Access

    Quantitative assessment of transmural fibrosis profile in the human atrium: evidence for a three-dimensional arrhythmic substrate by slice-to-slice histology

    by Flavia Ravelli, Michela Masè, Alessandro Cristoforetti, Laura Avogaro, Elvira D’aMato, Francesco Tessarolo, Federico Piccoli, Angelo Graffigna

    Intramural fibrosis represents a crucial factor in the formation of a three-dimensional (3D) substrate for atrial fibrillation (AF). However, the transmural distribution of fibrosis and its relationship with atrial overload remain largely unknown. The aim of this study is to quantify the transmural profile of atrial fibrosis in patients with different degrees of atrial dilatation and arrhythmic profiles by a high-resolution 3D histology method. Serial microtome-cut tissue slices, sampling the entire atrial wall thickness at 5 µm spatial resolution, were obtained from right atrial appendage specimens in 23 cardiac surgery patients. Atrial slices were picrosirius red stained, imaged by polarized light microscopy, and analysed by a custom-made segmentation algorithm. In all patients, the intramural fibrosis content displayed a progressive decrease alongside tissue depth, passing from 68.6 ± 11.6% in the subepicardium to 10–13% in the subendocardium. Distinct transmural fibrotic profiles were observed in patients with atrial dilatation with respect to control patients, where the first showed a slower decrease of fibrosis along tissue depth (exponential decay constant: 171.2 ± 54.5 vs. 80.9 ± 24.4 µm, P < 0.005). Similar slow fibrotic profiles were observed in patients with AF (142.8 ± 41.7 µm). Subepicardial and midwall levels of fibrosis correlated with the degree of atrial dilatation (ρ = 0.72, P < 0.001), while no correlation was found in subendocardial layers. Quantification of fibrosis transmural profile at high resolution is feasible by slice-to-slice histology. Deeper penetration of fibrosis in subepicardial and midwall layers in dilated atria may concur to the formation of a 3D arrhythmic substrate.


  • Open Access

    A Simple Method to Quantify Outward Leakage of Medical Face Masks and Barrier Face Coverings: Implication for the Overall Filtration Efficiency

    by Silvia Chiera, Alessandro Cristoforetti, Luca Benedetti, Giandomenico Nollo, Luca Borro, Lorenzo Mazzei, Francesco Tessarolo

    Face masking proved essential to reduce transmission of COVID-19 and other respiratory infections in indoor environments, but standards and literature do not provide simple quantitative methods for quantifying air leakage at the face seal. This study reports an original method to quantify outward leakage and how wearing style impacts on leaks and filtration efficiency. The amount of air leakage was evaluated on four medical masks and four barrier face coverings, exploiting a theoretical model and an instrumented dummy head in a range of airflows between 30 and 160 L/min. The fraction of air leaking at the face seal of the medical masks and barrier face coverings ranged from 43% to 95% of exhaled air at 30 L/min and reduced to 10–85% at 160 L/min. Filter breathability was the main driver affecting both leak fraction and total filtration efficiency that varied from 5% to 53% and from 15% to 84% at 30 and 160 L/min, respectively. Minor changes were related to wearing style, supporting indications on the correct mask use. The fraction of air leaking from medical masks and barrier face coverings during exhalation is relevant and varies according to design and wearing style. The use of highly breathable filter materials reduces air leaks and improve total filtration efficiency.


  • Remote Center of Motion and Synchronized Rotation for a Motorized Surgical Table

    by Alessandro Cristoforetti, Francesco Tessarolo, Marta Rigoni, Giandomenico Nollo

    Motion coordination between the operating table and imaging or surgical devices is becoming increasingly relevant for minimally invasive procedures in the hybrid operating room. In this paper, we presented a mathematical framework for the generation of a virtual remote center of motion (RCM) for a 5 degrees-of-freedom (DOFs) motorized surgical table. The capability of the table to synchronize its orientation to a rotating paired medical device was also addressed. The table inverse kinematic problem was solved by efficient algorithms, which were tested in a virtual simulation environment using a parametrized table model. The proposed solutions support arbitrary RCM position and can be adapted to different 5-DOFs table models by parameter tuning.