Ysabel Huaccallo-Aguilar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ysabel Huaccallo-Aguilar has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Uwe Hampel
Helmholtz-Zentrum Dresden - Rossendorf, Institute of Fluid Dynamics, Bautzner Landstraße 400, 01328 Dresden, Germany
4 shared publications - Amit Kumar
Institute of Physics, University of Belgrade, Belgrade, Serbia
3 shared publications - Juan García
Department of Chemical and Materials Engineering, Complutense University of Madrid, 28040 Madrid, Spain
3 shared publications - Markus Meier
Air Liquide Forschung & Entwicklung GmbH, Gwinnerstr. 27-33, D-60388 Frankfurt, Germany
3 shared publications - Sebastian Felix Reinecke
Helmholtz-Zentrum Dresden-Rossendorf, Institute of Fluid Dynamics, 01328 Dresden, Germany
3 shared publications - Silvia Álvarez-Torrellas
Catalysis and Separation Processes Group, Chemical Engineering and Materials Department, Faculty of Chemistry, Complutense University, Avda. Complutense s/n, 28040 Madrid, Spain
3 shared publications
Latest Publications
- Open Access
- 27 July 2026
- Published by Elsevier in SSRN Electronic Journal
Hydrodynamic cavitation enhanced by oxidants for degradation of ibuprofen as an emerging contaminant in water
Ibuprofen (IBU), one of the most widely used non-steroidal anti-inflammatory drugs (NSAIDs), is frequently detected in wastewater and aquatic environments due to its extensive consumption and incomplete removal by conventional wastewater treatment processes. Hydrodynamic cavitation (HC)-based advanced oxidation processes (AOPs) have emerged as a promising approach for the degradation of persistent organic pollutants. HC involves the formation, growth, and violent collapse of cavitation bubbles, generating localized extreme temperatures and pressures that promote the formation of highly reactive species, including hydroxyl radicals (•OH) and hydrogen radicals (•H), capable of degrading organic contaminants. In this study, the degradation of IBU in aqueous solution was investigated using an orifice-based HC reactor operated in combination with external oxidants. Experiments were conducted at an upstream pressure of 25 bar, corresponding to a cavitation number of 0.07, with 12 recirculation passes through the HC reactor. Hydrogen peroxide (H2O2) was added at different concentrations to enhance •OH generation and improve degradation performance. HC treatment alone achieved 26% IBU degradation, whereas the addition of H2O2 increased degradation efficiency to 55%. Additional experiments involving ozone (O3) injection during HC treatment were also performed and are discussed. Degradation kinetics were evaluated, and process performance was assessed using the electrical energy per order (EEO), which ranged from 8 to 58 kWh/(m3·order) under the investigated operating conditions. The results demonstrate that HC coupled with oxidants significantly enhances IBU degradation and represents a promising, energy-efficient, and scalable technology for the removal of pharmaceutical micropollutants from water.
- 27 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessHydrodynamic cavitation enhanced by oxidants for degradation of ibuprofen as an emerging contaminant in water
Ibuprofen (IBU), one of the most widely used non-steroidal anti-inflammatory drugs (NSAIDs), is frequently detected in wastewater and aquatic environments due to its extensive consumption and incomplete removal by conventional wastewater treatment processes. Hydrodynamic cavitation (HC)-based advanced oxidation processes (AOPs) have emerged as a promising approach for the degradation of persistent organic pollutants. HC involves the formation, growth, and violent collapse of cavitation bubbles, generating localized extreme temperatures and pressures that promote the formation of highly reactive species, including hydroxyl radicals (•OH) and hydrogen radicals (•H), capable of degrading organic contaminants. In this study, the degradation of IBU in aqueous solution was investigated using an orifice-based HC reactor operated in combination with external oxidants. Experiments were conducted at an upstream pressure of 25 bar, corresponding to a cavitation number of 0.07, with 12 recirculation passes through the HC reactor. Hydrogen peroxide (H2O2) was added at different concentrations to enhance •OH generation and improve degradation performance. HC treatment alone achieved 26% IBU degradation, whereas the addition of H2O2 increased degradation efficiency to 55%. Additional experiments involving ozone (O3) injection during HC treatment were also performed and are discussed. Degradation kinetics were evaluated, and process performance was assessed using the electrical energy per order (EEO), which ranged from 8 to 58 kWh/(m3·order) under the investigated operating conditions. The results demonstrate that HC coupled with oxidants significantly enhances IBU degradation and represents a promising, energy-efficient, and scalable technology for the removal of pharmaceutical micropollutants from water.
- Top Cited PapersOpen Access
- 16 January 2026
- Published by Elsevier in Chemical Engineering Journal Advances
- Vol. 25
Degradation and defluorination of perfluorooctane sulfonate (PFOS) forever chemical in water using hydrodynamic cavitation treatment
- 16 January 2026
- Published by Elsevier in Chemical Engineering Journal Advances
- Vol. 25
Top Cited PapersOpen AccessDegradation and defluorination of perfluorooctane sulfonate (PFOS) forever chemical in water using hydrodynamic cavitation treatment
- Top Cited PapersOpen Access
- 23 May 2025
- Published by Elsevier in Journal of Environmental Chemical Engineering
- Vol. 13 (4)
Characterization of reactive species in water induced by cold atmospheric air plasma: Experimental applications for industrial micropollutant removal from wastewater and seed germination
- 23 May 2025
- Published by Elsevier in Journal of Environmental Chemical Engineering
- Vol. 13 (4)
Top Cited PapersOpen AccessCharacterization of reactive species in water induced by cold atmospheric air plasma: Experimental applications for industrial micropollutant removal from wastewater and seed germination
- Open Access
Magnetite-Based Catalyst in the Catalytic Wet Peroxide Oxidation for Different Aqueous Matrices Spiked with Naproxen–Diclofenac Mixture
Magnetite supported on multiwalled carbon nanotubes catalysts were synthesized by co-precipitation and hydrothermal treatment. The magnetic catalysts were characterized by X-ray diffraction, Fourier-transform infrared spectrometry, thermogravimetric analysis and N2 physisorption. The catalysts were then tested for their ability to remove diclofenac (DCF) and naproxen (NAP) from an aqueous solution at different conditions (pH, temperature, and hydrogen peroxide) to determine the optimum conditions for chemical oxidation. The optimization of the process parameters was conducted using response surface methodology (RSM) coupled with Box–Behnken design (BBD). By RSM–BBD methodology, the optimal parameters (1.75 mM H2O2 dosage, 70 °C and pH 6.5) were determined, and the removal percentages of NAP and DCF were 19 and 54%, respectively. The NAP–DCF degradation by catalytic wet peroxide oxidation (CWPO) was caused by •OH radicals. In CWPO of mixed drug solutions, DCF and NAP showed competitive oxidation. Hydrophobic interactions played an important role during the CWPO process. On the other hand, the magnetic catalyst reduced its activity after the second cycle of reuse. In addition, proof of concept and disinfection tests performed at the operating conditions showed results following the complexity of the water matrices. In this sense, the magnetic catalyst in CWPO has adequate potential to treat water contaminated with NAP–DCF mixtures.
Open AccessMagnetite-Based Catalyst in the Catalytic Wet Peroxide Oxidation for Different Aqueous Matrices Spiked with Naproxen–Diclofenac Mixture
Magnetite supported on multiwalled carbon nanotubes catalysts were synthesized by co-precipitation and hydrothermal treatment. The magnetic catalysts were characterized by X-ray diffraction, Fourier-transform infrared spectrometry, thermogravimetric analysis and N2 physisorption. The catalysts were then tested for their ability to remove diclofenac (DCF) and naproxen (NAP) from an aqueous solution at different conditions (pH, temperature, and hydrogen peroxide) to determine the optimum conditions for chemical oxidation. The optimization of the process parameters was conducted using response surface methodology (RSM) coupled with Box–Behnken design (BBD). By RSM–BBD methodology, the optimal parameters (1.75 mM H2O2 dosage, 70 °C and pH 6.5) were determined, and the removal percentages of NAP and DCF were 19 and 54%, respectively. The NAP–DCF degradation by catalytic wet peroxide oxidation (CWPO) was caused by •OH radicals. In CWPO of mixed drug solutions, DCF and NAP showed competitive oxidation. Hydrophobic interactions played an important role during the CWPO process. On the other hand, the magnetic catalyst reduced its activity after the second cycle of reuse. In addition, proof of concept and disinfection tests performed at the operating conditions showed results following the complexity of the water matrices. In this sense, the magnetic catalyst in CWPO has adequate potential to treat water contaminated with NAP–DCF mixtures.
- 1 June 2019
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 26 (22) , 22372-22388
Magnetic Fe3O4/multi-walled carbon nanotubes materials for a highly efficient depletion of diclofenac by catalytic wet peroxideoxidation
- 1 June 2019
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 26 (22) , 22372-22388
Magnetic Fe3O4/multi-walled carbon nanotubes materials for a highly efficient depletion of diclofenac by catalytic wet peroxideoxidation
- Open Access
Optimization Parameters, Kinetics, and Mechanism of Naproxen Removal by Catalytic Wet Peroxide Oxidation with a Hybrid Iron-Based Magnetic Catalyst
This work presents a study of the assessment of the operating parameters of the catalytic wet peroxide oxidation (CWPO) of naproxen (NAP) using magnetite/multi-walled carbon nanotubes (Fe3O4/MWCNTs) as a catalyst. The effect of pH, temperature, and H2O2 dosage on CWPO process was evaluated by using the response surface model (RSM), allowing us to obtain an optimum NAP removal of 82% at the following operating conditions: pH = 5, T = 70 °C, [H2O2]0 = 1.5 mM, and [NAP]0 = 10.0 mg/L. Therefore, NAP degradation kinetics were revealed to follow a pseudo-second-order kinetic model, and an activation energy value of 4.75 kJ/mol was determined. Adsorption and using only H2O2 experiments, both considered as blank tests, showed no significant removal of the pollutant. Moreover, Fe3O4/MWCNTs material exhibited good recyclability along three consecutive cycles, finding an average NAP removal percentage close to 80% in each cycle of 3 h reaction time. In addition, the scavenging tests confirmed that the degradation of NAP was mainly governed by •OH radicals attack. Two reaction sequences were proposed for the degradation mechanism according to the detected byproducts. Finally, the versatility of the catalyst was evidenced in the treatment of different environmentally relevant aqueous matrices (wastewater treatment plant effluent (WWTP), surface water (SW), and a hospital wastewater (HW)) spiked with NAP, obtaining total organic carbon (TOC) removal efficiencies after 8 h in the following order: NAP-SW > NAP-HW > NAP-WWTP.
Open AccessOptimization Parameters, Kinetics, and Mechanism of Naproxen Removal by Catalytic Wet Peroxide Oxidation with a Hybrid Iron-Based Magnetic Catalyst
This work presents a study of the assessment of the operating parameters of the catalytic wet peroxide oxidation (CWPO) of naproxen (NAP) using magnetite/multi-walled carbon nanotubes (Fe3O4/MWCNTs) as a catalyst. The effect of pH, temperature, and H2O2 dosage on CWPO process was evaluated by using the response surface model (RSM), allowing us to obtain an optimum NAP removal of 82% at the following operating conditions: pH = 5, T = 70 °C, [H2O2]0 = 1.5 mM, and [NAP]0 = 10.0 mg/L. Therefore, NAP degradation kinetics were revealed to follow a pseudo-second-order kinetic model, and an activation energy value of 4.75 kJ/mol was determined. Adsorption and using only H2O2 experiments, both considered as blank tests, showed no significant removal of the pollutant. Moreover, Fe3O4/MWCNTs material exhibited good recyclability along three consecutive cycles, finding an average NAP removal percentage close to 80% in each cycle of 3 h reaction time. In addition, the scavenging tests confirmed that the degradation of NAP was mainly governed by •OH radicals attack. Two reaction sequences were proposed for the degradation mechanism according to the detected byproducts. Finally, the versatility of the catalyst was evidenced in the treatment of different environmentally relevant aqueous matrices (wastewater treatment plant effluent (WWTP), surface water (SW), and a hospital wastewater (HW)) spiked with NAP, obtaining total organic carbon (TOC) removal efficiencies after 8 h in the following order: NAP-SW > NAP-HW > NAP-WWTP.