Raymond Liddle
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Raymond Liddle has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Edward Halawa
Faculty of Science and Technology, Charles Darwin University, Darwin, NT 0810, Australia
2 shared publications - Alemu Alemu
University of South Australia, Australia
1 shared publication - David Whaley
University of South Australia
1 shared publication - Frank Bruno
University of South Australia
1 shared publication - Martin Belusko
University of South Australia, Adelaide, SA, Australia
1 shared publication - Stephen Berry
University of South Australia
1 shared publication
Latest Publications
- 19 May 2022
- Published by Springer Nature
- p. 153-169
The Effectiveness of Gas-Boosted Solar Water Heaters in an Australian Monitored Low-Energy Housing Development
- 19 May 2022
- Published by Springer Nature
- p. 153-169
The Effectiveness of Gas-Boosted Solar Water Heaters in an Australian Monitored Low-Energy Housing Development
- Open Access
Performance Evaluation of a CO2 Refrigeration System Enhanced with a Dew Point Cooler
Dew point cooling (DPC) is a novel indirect evaporative cooling concept capable of delivering air temperatures approaching the dew point. Coupling this technology with CO2 refrigeration is well suited to minimising transcritical operation when the coefficient of performance (COP) is dramatically reduced in hot climates. A substantial experimental program was conducted to characterise this combination by testing a 20 kW CO2 refrigeration system subject to ambient temperatures above 40 °C. It was demonstrated that DPC operation not only avoided transcritical operation during such weather conditions, but also increased the COP by up to 140% compared to the conventional system. The combination of these technologies was successfully mathematically modelled, from which the optimum condenser inlet air temperature was identified for each condenser temperature. Using this optimum condition, it was possible to maximise the COP for a range of conditions applicable to the psychometric chart. An annual case study for Adelaide, Australia was conducted which demonstrated that optimally coupling DPC with CO2 refrigeration can reduce the annual energy consumption and peak demand by 16% and 47%, respectively, compared to a conventional CO2 booster system. Furthermore, the number of hours of transcritical operation was reduced from 3278 to 27.
Open AccessPerformance Evaluation of a CO2 Refrigeration System Enhanced with a Dew Point Cooler
Dew point cooling (DPC) is a novel indirect evaporative cooling concept capable of delivering air temperatures approaching the dew point. Coupling this technology with CO2 refrigeration is well suited to minimising transcritical operation when the coefficient of performance (COP) is dramatically reduced in hot climates. A substantial experimental program was conducted to characterise this combination by testing a 20 kW CO2 refrigeration system subject to ambient temperatures above 40 °C. It was demonstrated that DPC operation not only avoided transcritical operation during such weather conditions, but also increased the COP by up to 140% compared to the conventional system. The combination of these technologies was successfully mathematically modelled, from which the optimum condenser inlet air temperature was identified for each condenser temperature. Using this optimum condition, it was possible to maximise the COP for a range of conditions applicable to the psychometric chart. An annual case study for Adelaide, Australia was conducted which demonstrated that optimally coupling DPC with CO2 refrigeration can reduce the annual energy consumption and peak demand by 16% and 47%, respectively, compared to a conventional CO2 booster system. Furthermore, the number of hours of transcritical operation was reduced from 3278 to 27.