Bo Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Bo Xu has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Renwei Ma
Jiangsu Key Laboratory of Environmental Impact and Structural Safety in Engineering, China University of Mining and Technology, Xuzhou 221116, China
2 shared publications - Junwu Xia
State Key Laboratory of Intelligent Construction and Healthy Operation and Maintenance of Deep Underground Engineering, China University of Mining and Technology, Xuzhou 221116, China
1 shared publication - Junwu Xia
Jiangsu Key Laboratory of Environmental Impact and Structural Safety in Engineering, China University of Mining and Technology, Xuzhou 221116, China
1 shared publication - Tonglei Wang
Jiangsu Key Laboratory of Environmental Impact and Structural Safety in Engineering, China University of Mining and Technology, Xuzhou 221116, China
1 shared publication - Xiaomiao Chen
Jiangsu Key Laboratory of Environmental Impact and Structural Safety in Engineering, China University of Mining and Technology, Xuzhou 221116, China
1 shared publication - Yongrui Wang
Jiangsu Key Laboratory of Environmental Impact and Structural Safety in Engineering, China University of Mining and Technology, Xuzhou 221116, China
1 shared publication
Latest Publications
- Open Access
- 22 August 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (17) , 3468
Experimental Study on the Flexural Behavior of an Innovative Modular Steel Building Connection with Installed Bolts in the Columns
Modular buildings have the highest levels of precasting in the current building system. There are some defects in present modular connections, such as the difficulties of construction, the weakening of the bearing capacity of beams or columns, and damage to decorations. This paper presents an innovative modular connection with installed bolts in the columns. Two symmetrical monotonous static loading tests were conducted to explore the flexural behavior of the innovative connection. Meanwhile, the moment–rotation relations, destruction process, ultimate bearing capacity, stiffness classification and internal stress distribution were analyzed. The results showed that the specimen S1 with smaller diagonal stiffeners lost its bearing capacity due to the failure of the welding seam, and the extreme moment was 169 kN·m. The failure mode of S2 with large diagonal stiffeners was beam buckling, and the extreme moment was 209 kN·m. The stress of diagonal stiffeners and the join between the upper beam and stiffeners increased rapidly. Stiffeners can increase the stiffness and load-bearing capacity. The connection failures occurred on the beam or beam–column joints, while the connection between modules remained undamaged, which showed that the new connection has a good bearing capacity under the action of bending moment and pressure.
- 22 August 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (17) , 3468
Open AccessExperimental Study on the Flexural Behavior of an Innovative Modular Steel Building Connection with Installed Bolts in the Columns
Modular buildings have the highest levels of precasting in the current building system. There are some defects in present modular connections, such as the difficulties of construction, the weakening of the bearing capacity of beams or columns, and damage to decorations. This paper presents an innovative modular connection with installed bolts in the columns. Two symmetrical monotonous static loading tests were conducted to explore the flexural behavior of the innovative connection. Meanwhile, the moment–rotation relations, destruction process, ultimate bearing capacity, stiffness classification and internal stress distribution were analyzed. The results showed that the specimen S1 with smaller diagonal stiffeners lost its bearing capacity due to the failure of the welding seam, and the extreme moment was 169 kN·m. The failure mode of S2 with large diagonal stiffeners was beam buckling, and the extreme moment was 209 kN·m. The stress of diagonal stiffeners and the join between the upper beam and stiffeners increased rapidly. Stiffeners can increase the stiffness and load-bearing capacity. The connection failures occurred on the beam or beam–column joints, while the connection between modules remained undamaged, which showed that the new connection has a good bearing capacity under the action of bending moment and pressure.
- Open Access
- 21 March 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (6) , 1204
Mechanical Performance of Built-Up Columns Composed of Four Cold-Formed Square Steel Tubes
This study presents an experimental investigation into the mechanical performance of built-up columns composed of four cold-formed square steel tubes under axial load. The four tubes were assembled together with several C-shaped connectors through two self-tapping screws in each junction. The influence of parameters including spacing between tubes, type of connectors and transverse diaphragm were analyzed based on the failure modes, ultimate loads, load-displacement relationships and load-strain relationships measured in the tests. Moreover, a further numerical analysis was carried out to study the effect of the number of connectors, web height of connectors and installing connectors at column ends by means of the verified finite element models. Finally, the numerical results were compared with the strengths predicted by the AISI-S100-2012 code. Results show that the performance of built-up columns can be influenced by the change in the number of connectors and ratio of web height of connectors to spacing between tubes as well as the installation of connectors at column ends. In addition, the current AISI-S100-12 specifications do not provide a good prediction of the built-up columns composed of four cold-formed square steel tubes.
- 21 March 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (6) , 1204
Open AccessMechanical Performance of Built-Up Columns Composed of Four Cold-Formed Square Steel Tubes
This study presents an experimental investigation into the mechanical performance of built-up columns composed of four cold-formed square steel tubes under axial load. The four tubes were assembled together with several C-shaped connectors through two self-tapping screws in each junction. The influence of parameters including spacing between tubes, type of connectors and transverse diaphragm were analyzed based on the failure modes, ultimate loads, load-displacement relationships and load-strain relationships measured in the tests. Moreover, a further numerical analysis was carried out to study the effect of the number of connectors, web height of connectors and installing connectors at column ends by means of the verified finite element models. Finally, the numerical results were compared with the strengths predicted by the AISI-S100-2012 code. Results show that the performance of built-up columns can be influenced by the change in the number of connectors and ratio of web height of connectors to spacing between tubes as well as the installation of connectors at column ends. In addition, the current AISI-S100-12 specifications do not provide a good prediction of the built-up columns composed of four cold-formed square steel tubes.