GZGuofeng Zhang

Guofeng Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Guofeng Zhang has a total of 84 co-authors. Here are the top co-authors by number of shared publications:

  • Yongliang Wang

    Shanghai Institute of Microsystem and Information Technology (SIMIT), Chinese Academy of Sciences (CAS), Shanghai, China

    15 shared publications
  • Liangliang Rong

    Shanghai Key Laboratory of Superconductor Integrated Circuit Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China

    14 shared publications
  • Jun Wu

    Shanghai Key Laboratory of Superconductor Integrated Circuit Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China

    9 shared publications
  • Hui Dong

    Shanghai Key Laboratory of Superconductor Integrated Circuit Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China

    8 shared publications
  • Jun Wu

    7 shared publications
  • Longqing Qiu

    Shanghai Key Laboratory of Superconductor Integrated Circuit Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China

    7 shared publications

Latest Publications

  • Open Access

    Low-Frequency Noise Characterization and Mechanisms in High-Swing Multi-loop SQUID Magnetometers with Sub-micron Josephson Junctions

    by Shumin Yu, Guofeng Zhang, Jun Wu, Jiawei Luo, Yongliang Wang, Xiaojun Dai, Longqing Qiu, Liangliang Rong

    This paper reports a high-swing multi-loop SQUID magnetometer based on Nb/Al-AlOx/Nb sub-micron Josephson junctions. By optimizing damping parameters via a shunt resistance of several tens of ohms, the device operates under weakly damped conditions. Consequently, the voltage swing is enhanced to approximately 300 μV with the flux-to-voltage transfer coefficient ∂V/∂Φ reaching 1.78 mV/Φ0, which reduces the influence of readout circuitry. Utilizing a combined frequency- and time-domain characterization approach, this study systematically analyzes the low-frequency noise mechanisms of the device. Frequency-domain measurements reveal a white noise as low as 4.15 fT/√Hz, with a 1/f noise corner frequency of ~10 Hz. In the 1 -10 Hz band, the magnetic field noise spectral density exhibits a dependence of 8.09×10-15/f1.09 T/√Hz, accompanied by step-like Lorentzian peaks. This indicates that the noise in this regime is influenced by two-level fluctuations and critical current jumps induced by interface defects. In the 0.1 -1 Hz band, the noise spectrum transitions to a 1/f0.42 dependence (5.43×10-15/f 0.42 T/√Hz), suggesting that environmental thermal drift and background magnetic field fluctuations become the dominant factors. Furthermore, to address the non-stationarity issue associated with ultralow-frequency FFT analysis, time-domain measurements within the 0.04 -0.4 Hz range were conducted. The measured equivalent magnetic field fluctuation is merely 0.08 pT, which verifies the ultimate resolution of the device at ultralow frequencies. This study elucidates the physical mechanisms of low-frequency noise in multi-loop SQUIDs, providing a solid experimental foundation for their applications in weak magnetic field detection within unshielded or weakly shielded environments.

  • Development of a High-Sensitivity, 80-mm Long-Baseline, Monolithically Integrated SQUID First-Order Gradiometer

    by Shumin Yu, Guofeng Zhang, Jun Wu, Jiawei Luo, Yongliang Wang, Longqing Qiu, Liangliang Rong

    This paper presents a high-sensitivity, monolithically integrated SQUID first-order gradiometer with an 80 mm long baseline. The device exhibits a magnetic gradient noise as low as 10 fT/(m·√Hz), representing an approximately 20% improvement over the current state-of-the-art. This achievement is attributed to a combination of innovations in both design and fabrication. In the design phase, theoretical analysis and numerical simulations were employed to optimize the SQUID and pickup coil parameters, achieving an optimal balance between coupling efficiency and parasitic effects. This yielded superior intrinsic performance, including a voltage swing of 217 μV, a voltage-to-flux transfer coefficient of 1450 μV/Φ0, and a magnetic gradient-to-flux conversion coefficient of 9.66 nT/m/Φ0. In fabrication, an optimized hybrid lithography process addressed the cross-scale challenges from 80 mm to sub-micron levels. Furthermore, the introduction of organic cleaning and the optimization of metal wiring thickness effectively resolved step coverage issues, significantly improving device yield. These outstanding intrinsic properties significantly reduce noise contributions from the readout circuitry, thereby enabling a substantial improvement in overall system performance. This work demonstrates the fabrication feasibility and exceptional performance of long-baseline integrated SQUID gradiometers, laying a technological foundation for next-generation ultra-high-sensitivity magnetic sensing systems.

  • Two-Step Nonlinear Calibration of LTS SQUID-based Full Tensor Magnetic Gradient System

    by Tingli Liu, Longqing Qiu, Zhengwei Song, Jiawei Luo, Xingcheng Gong, Yuhong Cheng, Guofeng Zhang, Liangliang Rong

    The full tensor magnetic gradient (FTMG) system based on low-temperature superconducting quantum interference device (SQUID) planar gradiometers is susceptible to measurement errors, including imbalance errors, angular misalignment, scale factor deviations, and offset errors. To mitigate these effects, a two-step calibration method is proposed. In the first step, a three-dimensional Helmholtz coil generates a known magnetic field to correct imbalance and offset errors. In the second step, the FTMGmodule is rotated within a Maxwell coil to obtain outputs from all gradiometers. By minimizing the objective function between modeled and measured responses, the estimated error parameters can be obtained using the Trust-Region Reflective algorithm. Simulation results show that the mean absolute percentage error (MAPE) between the estimated and true parameters remains below 10%. Experimental validation further confirms the reliability of the method, as the residual magnetic gradient components for the six calibrated gradiometers are reduced from 688.16, 1017.32, 341.18, 532.45, 874.24, and 268.07 nT/m to 0.52, 0.30, 0.57, 0.35, 0.39, and 0.36 nT/m, respectively. These results demonstrate that the proposed approach significantly enhances the accuracy and stability of FTMG measurements.

  • Sub-μm Sized Josephson Junctions Based LTS SQUID Receiver for Transient Electromagnetic Surveys

    by Yifeng Pei, Guofeng Zhang, Longqing Qiu, Jun Wu, Jinhui Zhang, Hui Dong, Liangliang Rong

    Superconducting Quantum Interference Device (SQUID) magnetometers combine low noise, wide bandwidth, and high tolerance to magnetic field slew rates. These characteristics significantly enhance the depth and accuracy of transient electromagnetic (TEM) surveys. In this paper, we developed a high-performance superconducting TEM receiver using low temperature superconductors (LTS) SQUID chips fabricated via sub-μm Josephson-junction integration. The design boosts sensor output amplitudes from tens of microvolts (μV) to over 200 μV. The SQUID sensors achieve a noise floor below 5 fT/√Hz, and the system tolerates magnetic field slew rates exceeding 5 mT/s. Side-by-side field tests comparing the system against a commercial Phoenix V8 multipurpose network electrical instrument equipped with an MTEM-AL induction coil showed approximately 30-fold improvement in effective late-time resolution. Additional validation surveys were conducted at two sites in China: a gold deposit concealed beneath conductive overburden in Anhui Province, and a deep copper deposit in Heilongjiang Province. The TEM results from both sites correlated well with borehole logs, demonstrating that SQUID-based TEM receiver can effectively explore targets beneath conductive cover and/or at greater depths.


  • Design and Characterization of a DC-SQUID Amplifier for TES Detectors

    by Wentao Wu, Shuo Zhang, Guofeng Zhang, Liliang Ying, Zhirong Lin, Liangliang Rong, Wei Peng, Lixing You

    The DC Superconducting Quantum Interference Device (DC-SQUID) has been widely recognized as the preferred readout technology for high-sensitivity superconducting transition edge sensors. In this study, we present the design, fabrication, and characterization of a novel first-order gradiometric DC-SQUID amplifier incorporating intracoil resistors, specifically tailored for TES detector applications. The measured results demonstrate that the proposed intracoil resistors design significantly enhances the flux–voltage transfer coefficient VΦ. Through a systematic comparative analysis of various intracoil resistor configurations, we observe a positive correlation between VΦ and the intracoil resistor conductance. This enhancement in VΦ effectively reduces the noise contribution from the backend readout circuit, thereby improving the overall system sensitivity. The developed amplifier has been successfully implemented into the readout system of an X-ray TES microcalorimeter, demonstrating its practical applicability in high-performance detector systems.

  • Wafer-Scale Fabrication and Spatial Uniformity Evaluation of SQUIDs With Submicron Josephson Junctions

    by Shumin Yu, Guofeng Zhang, Haiyang Mao, Jun Wu, Jiawei Luo, Yongliang Wang, Longqing Qiu, Liangliang Rong

    This article reports the wafer-scale fabrication of dc superconducting quantum interference devices (dc-SQUIDs) on 4-in silicon wafers, employing a submicron Josephson junction cross-line process that integrates i-line stepper lithography, in situ trilayer deposition, and a self-aligned insulating layer. Using a stratified regional sampling strategy, 10 SQUIDs are selected from each of the center, transition, and edge regions of the wafer (achieving a total coverage of 49.2%), and the spatial uniformity of key parameters such as critical current, voltage swing, and system flux noise is systematically evaluated. The test results show that the critical currents for the central, transition, and edge regions are (25.4±1.77) μA, (22.4±2.13) μA, and (16.2±2.81) μA, respectively; their corresponding voltage swings are (275±5.95) μV, (255±17.8) μV, and (146±44.7) μV, respectively; and the system flux noises are (1.74±0.131) μΦ0/√Hz, (1.97±0.0880) μΦ0/√Hz, and (2.70±0.452) μΦ0/√Hz, respectively. Statistical analysis shows that from the center to the edge, the critical current and voltage swing demonstrate a downward trend, whereas the system flux noise shows a trend of deterioration. The standard deviation of these parameters gradually increases from the center to the edge, which indicates poorer parameter consistency and more pronounced fluctuations in the region. Further analysis of the coefficient of variation (CV) shows that the CVs of key parameters in the central and transition regions are all below 10%. This verifies that the process route, particularly in these central and transition regions, possesses excellent spatial uniformity, providing a crucial process foundation and data support for the large-scale manufacturing of high-performance SQUIDs.


  • Ultralow Field MRI Image Reconstruction at 0.1 mT Using Manifold and Sparsity Constraints

    by Xue Ren, Quan Tao, Kai Buckenmaier, Zhexin Wan, Ting Zhou, Guofeng Zhang, Jun Wu, Longqing Qiu, Liangliang Rong, Wentao Pan, et al.

  • Weakly Damped SQUID With Submicron Josephson Junctions

    by Guofeng Zhang, Shumin Yu, Yifeng Pei, Jun Wu, Yongliang Wang, Longqing Qiu, Hui Dong, Liangliang Rong, Y. Zhang, Xiaoming Xie

    A superconducting quantum interference device (SQUID) consists of a superconducting loop interrupted by one or two Josephson junctions. Overdamped Josephson junctions, characterized by a Stewart–McCumber parameter (βc) below 1, are typically required as the key element of SQUIDs due to their nonhysteretic I–V characteristics. In the overdamped limit, the junction's shunt resistance is only a few ohms, leading to a SQUID voltage swing of just tens of μV. Consequently, connecting the SQUID to readout circuitry necessitates a complex noise-matching electronic circuit, such as those using flux modulation, adaptive positive feedback, or a SQUID bootstrap circuit. Here, we present a weakly damped SQUID designed for direct connection to the readout circuitry. This is achieved first by incorporating a submicron, low-capacitance Josephson junction, which allows the shunt resistance to be increased to tens of ohms. Second, the shunt resistance is increased further, resulting in a βc greater than 1, defining what is known as a weakly damped junction. This design achieves a high flux-to-voltage transfer coefficient of over 1 mV/Φ0, attributable to the increased voltage swing and a quasi-rectangular signal shape. As a result, the noise contribution from the preamplifier of the direct readout circuitry becomes negligible compared to the SQUID's intrinsic noise.

  • Design and Performance Evaluation of Superconducting Wire-Wound Gradiometers for SQUID-Based Ultralow-Field MRI

    by Zhexin Wan, Quan Tao, Xue Ren, Guofeng Zhang, Jun Wu, Longqing Qiu, Liangliang Rong, Hui Dong

    In recent years, ultralow-field (ULF) magnetic resonance imaging (MRI) has shown its potential in portable MRI System. As the superconducting magnet is replaced by permanent magnet or electronic magnet, the weight and the cost of the system could be effectively reduced. However, the low main field strength leads to low signal-to-noise ratio. Superconducting quantum interference devices (SQUIDs), as the most sensitive magnetic flux sensors known to date, have been employed in the system to measure the weak magnetic signal. Since a bare SQUID chip has limited magnetic field resolution and insufficient adaptability to the practical environment, a flux transformer, which consists of a pickup coil and input coil, is typically introduced and coupled with the SQUID. For example, in our Al shielded ULF MRI system, second-order axial gradiometers are applied as pickup coils to suppress the external magnetic field noise, thus, enhance the signal-to-noise ratio (SNR). However, the geometrical parameters of gradiometers significantly affect their performance, which includes the ability to suppress the ambient noise and the sensitivity to the signal. In this paper, we first present geometrical requirements of the second-order gradiometers to ensure that the designed configurations have equal noise suppression ability. Then, we acquire a general expression of the sensitivity pattern of a second-order gradiometer through mathematical calculation. Through the above two steps, we propose a design and evaluation method for second-order SQUID-based gradiometers for ULF MRI. Based on this method, an asymmetric configuration wire-wound gradiometer with optimized loop numbers is proposed and applied in our ULF MRI system. Compared to the conventional symmetric configuration gradiometer, the proposed one achieved approximately a 1.5-fold improvement in sensitivity to the signal for a shallow imaging slice while maintaining similar noise suppression capabilities. This improvement offers a broader imaging area and higher measurement accuracy for the ULF MRI system. All code and data used in this study are openly available to ensure reproducibility, following IEEE reproducibility guidelines.