Seung-Ho Choi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Seung-Ho Choi has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
- Kang Su Kim
Department of Architectural Engineering and Smart City Interdisciplinary Major Program, University of Seoul, Seoul, Republic of Korea
23 shared publications - Deuck Hang Lee
School of Civil and Architectural Engineering & Department of Global Smart City, Sungkyunkwan University, Suwon, Korea
12 shared publications - Sun-Jin Han
Department of Architectural Engineering, University of Seoul, 163 Seoulsiripdaero, Dongdaemun-gu, Seoul 02504, Korea
12 shared publications - Inwook Heo
Urban Safety and Security Research Institute, University of Seoul, Seoul, South Korea
11 shared publications Khaliunaa Darkhanbat
Department of Architectural Engineering, University of Seoul, Seoul, South Korea
5 shared publicationsDoohee Lee
4 shared publications
Latest Publications
- Open Access
- 15 October 2026
- Published by Springer Nature in Scientific Reports
A study on floor plan design for postpartum care centers considering egress safety
- 15 October 2026
- Published by Springer Nature in Scientific Reports
Open AccessA study on floor plan design for postpartum care centers considering egress safety
- Open Access
- 1 September 2026
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 86
Fire−induced thermo−structural response of reinforced concrete beams in underground parking lots
- 1 September 2026
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 86
Open AccessFire−induced thermo−structural response of reinforced concrete beams in underground parking lots
- Open Access
- 18 April 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Development of an artificial neural network–based egress model incorporating the egress safety ratio under fire in postpartum care center buildings
Fires in postpartum care centers pose significant risks to the safety of mothers and newborns, highlighting the need for effective egress safety evaluation. This study proposes a systematic method for assessing egress safety based on the Egress Safety Ratio in postpartum care center buildings. Fire simulations were conducted to analyze the correlation between fire environment factors (e.g., temperature, toxic gases) and available safe egress time, which served as the foundation for constructing a comprehensive database. Using this database, an artificial neural network-based real-time prediction model was developed, enabling the identification of safe egress routes under various fire scenarios. Additionally, an integrated system for quantitatively evaluating Egress Safety Ratio was established. The reliability of the proposed model was validated by comparing fire simulation results with artificial neural network-based predictions using different postpartum care center floor plans, demonstrating good agreement and confirming its accuracy and effectiveness in evaluating and improving egress safety. The proposed model is expected to serve as a valuable tool for enhancing fire safety in postpartum care centers.
- 18 April 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessDevelopment of an artificial neural network–based egress model incorporating the egress safety ratio under fire in postpartum care center buildings
Fires in postpartum care centers pose significant risks to the safety of mothers and newborns, highlighting the need for effective egress safety evaluation. This study proposes a systematic method for assessing egress safety based on the Egress Safety Ratio in postpartum care center buildings. Fire simulations were conducted to analyze the correlation between fire environment factors (e.g., temperature, toxic gases) and available safe egress time, which served as the foundation for constructing a comprehensive database. Using this database, an artificial neural network-based real-time prediction model was developed, enabling the identification of safe egress routes under various fire scenarios. Additionally, an integrated system for quantitatively evaluating Egress Safety Ratio was established. The reliability of the proposed model was validated by comparing fire simulation results with artificial neural network-based predictions using different postpartum care center floor plans, demonstrating good agreement and confirming its accuracy and effectiveness in evaluating and improving egress safety. The proposed model is expected to serve as a valuable tool for enhancing fire safety in postpartum care centers.
- 26 January 2026
- Published by Wiley in Fire and Materials
- Vol. 50 (2) , 174-192
Regression and ANN ‐Based Prediction of Fire Temperature Curves for Single‐Vehicle Fires in Underground Parking Structures
Vehicle fires in underground parking structures can cause rapid temperature rises, posing significant threats to both structural integrity and occupant safety. This study develops predictive models for quantitatively estimating fire temperatures in single‐vehicle fire scenarios within underground parking structures. A total of 25 single‐vehicle fire test datasets were collected, and the maximum heat release rate, time to reach maximum heat release rate, and duration of maximum heat release rate were analyzed for each vehicle type. Based on the analysis results, various fire scenarios were constructed, and fire simulations were performed to derive time–temperature curves for each fire scenario. From the simulated curves, regression‐based and artificial neural network (ANN)‐based prediction models were developed to estimate the peak temperature and the temperature at the end of combustion for each fire scenario, using heat release rate as input variables. The predictive performance of both models was validated against the fire simulation results, with coefficients of variation below 0.2 and coefficients of determination above 0.84, indicating high accuracy. Furthermore, to examine the applicability of the proposed time–temperature curves to structural fire analysis, nonlinear finite element analysis of reinforced concrete beams was performed for fire resistance assessment. The results showed that the structural fire behavior predicted using the regression and ANN‐based curves closely matched that obtained using fire simulation‐based curves. The proposed temperature prediction models are expected to be effective tools for estimating thermal loads and evaluating the fire safety of structures subjected to single‐vehicle fires in underground parking facilities.
- 26 January 2026
- Published by Wiley in Fire and Materials
- Vol. 50 (2) , 174-192
Regression and ANN ‐Based Prediction of Fire Temperature Curves for Single‐Vehicle Fires in Underground Parking Structures
Vehicle fires in underground parking structures can cause rapid temperature rises, posing significant threats to both structural integrity and occupant safety. This study develops predictive models for quantitatively estimating fire temperatures in single‐vehicle fire scenarios within underground parking structures. A total of 25 single‐vehicle fire test datasets were collected, and the maximum heat release rate, time to reach maximum heat release rate, and duration of maximum heat release rate were analyzed for each vehicle type. Based on the analysis results, various fire scenarios were constructed, and fire simulations were performed to derive time–temperature curves for each fire scenario. From the simulated curves, regression‐based and artificial neural network (ANN)‐based prediction models were developed to estimate the peak temperature and the temperature at the end of combustion for each fire scenario, using heat release rate as input variables. The predictive performance of both models was validated against the fire simulation results, with coefficients of variation below 0.2 and coefficients of determination above 0.84, indicating high accuracy. Furthermore, to examine the applicability of the proposed time–temperature curves to structural fire analysis, nonlinear finite element analysis of reinforced concrete beams was performed for fire resistance assessment. The results showed that the structural fire behavior predicted using the regression and ANN‐based curves closely matched that obtained using fire simulation‐based curves. The proposed temperature prediction models are expected to be effective tools for estimating thermal loads and evaluating the fire safety of structures subjected to single‐vehicle fires in underground parking facilities.
- 8 January 2026
- Published by Elsevier in Journal of Building Engineering
- Vol. 119
Construction-stage structural performance of beams with steel permanent formwork: Experimental and numerical approach
- 8 January 2026
- Published by Elsevier in Journal of Building Engineering
- Vol. 119
Construction-stage structural performance of beams with steel permanent formwork: Experimental and numerical approach
- Open Access
- 1 December 2025
- Published by The Royal Society in Royal Society Open Science
- Vol. 12 (12)
Performance-based egress safety assessment of underground tunnels: simulation and artificial neural network approaches
In this study, an artificial neural network (ANN) model was proposed to evaluate the egress safety of underground tunnels during fire. Fire simulations were carried out using the Fire Dynamics Simulator (FDS) for underground tunnels with a general cross-section, considering fire size as a key variable. In addition, egress simulations were performed using the Pathfinder program, with the spacing of cross-passage and the width of fire doors set as variables. Through this process, the available safe egress time (ASET), required safe egress time (RSET) and the number of casualties were derived for each variable, and the egress safety characteristics of underground tunnels under various parameter combinations were analysed in detail. Based on the derived data, an ANN model was developed to derive the ASET, RSET and survival rate in underground tunnels during fire incidents. The proposed ANN model is expected to efficiently evaluate the egress safety of underground tunnels with general dimensions without the need to perform additional fire and egress simulations. The ANN-based prediction model achieved coefficients of determination (R²) of 0.99 for ASET, 0.99 for RSET and 0.98 for survival rate, with average error rates of 1.72%, 1.36% and 2.31%, respectively, demonstrating very high accuracy.
- 1 December 2025
- Published by The Royal Society in Royal Society Open Science
- Vol. 12 (12)
Open AccessPerformance-based egress safety assessment of underground tunnels: simulation and artificial neural network approaches
In this study, an artificial neural network (ANN) model was proposed to evaluate the egress safety of underground tunnels during fire. Fire simulations were carried out using the Fire Dynamics Simulator (FDS) for underground tunnels with a general cross-section, considering fire size as a key variable. In addition, egress simulations were performed using the Pathfinder program, with the spacing of cross-passage and the width of fire doors set as variables. Through this process, the available safe egress time (ASET), required safe egress time (RSET) and the number of casualties were derived for each variable, and the egress safety characteristics of underground tunnels under various parameter combinations were analysed in detail. Based on the derived data, an ANN model was developed to derive the ASET, RSET and survival rate in underground tunnels during fire incidents. The proposed ANN model is expected to efficiently evaluate the egress safety of underground tunnels with general dimensions without the need to perform additional fire and egress simulations. The ANN-based prediction model achieved coefficients of determination (R²) of 0.99 for ASET, 0.99 for RSET and 0.98 for survival rate, with average error rates of 1.72%, 1.36% and 2.31%, respectively, demonstrating very high accuracy.
- 1 October 2025
- Published by Taylor & Francis in Architectural Engineering and Design Management
- Vol. 22 (3) , 1-24
Fire resistance assessment of reinforced concrete slabs and beams under vehicle fires in mechanical parking structures
- 1 October 2025
- Published by Taylor & Francis in Architectural Engineering and Design Management
- Vol. 22 (3) , 1-24
Fire resistance assessment of reinforced concrete slabs and beams under vehicle fires in mechanical parking structures
- Open Access
Egress Safety for STUDIO Residential Buildings
In recent years, the number of studio residential buildings has increased significantly in Korea, as well as in many other countries, due to changes in living patterns. In Korea especially, there have been many fire accidents in studio residential buildings, which have caused a huge number of casualties and property damages, because the buildings were not adequately equipped for firefighting. In this study, the egress safety of a typical studio residential building in Korea is analyzed. Fire simulations were performed with variables of the fire location and the capacity of the smoke exhaust system to estimate the available safe egress time (ASET); egress simulations were also performed with the variable of egress delay time, and the required safe egress time (RSET) was determined. Then, the egress safety was evaluated, and the criteria for egress safety evaluation were proposed based on the simulation results. A studio residential building with a floor plan different from the prototype was used to validate the proposed egress safety criteria. Finally, a simple evaluation model is presented to estimate the required safe egress time (RSET) without simulation and to examine the impact of bottlenecks.
Open AccessEgress Safety for STUDIO Residential Buildings
In recent years, the number of studio residential buildings has increased significantly in Korea, as well as in many other countries, due to changes in living patterns. In Korea especially, there have been many fire accidents in studio residential buildings, which have caused a huge number of casualties and property damages, because the buildings were not adequately equipped for firefighting. In this study, the egress safety of a typical studio residential building in Korea is analyzed. Fire simulations were performed with variables of the fire location and the capacity of the smoke exhaust system to estimate the available safe egress time (ASET); egress simulations were also performed with the variable of egress delay time, and the required safe egress time (RSET) was determined. Then, the egress safety was evaluated, and the criteria for egress safety evaluation were proposed based on the simulation results. A studio residential building with a floor plan different from the prototype was used to validate the proposed egress safety criteria. Finally, a simple evaluation model is presented to estimate the required safe egress time (RSET) without simulation and to examine the impact of bottlenecks.
- Open Access
- 4 December 2023
- Published by Springer Nature in Research Square
Optical Sensor for Monitoring Corrosion of Rebar in Reinforced Concrete Members Using Polydimethylsiloxane - Titanium Oxide Composite
Corrosion of reinforcing bars deteriorates the bond between the rebar and concrete, consequently leading to the degradation of the strength and stiffness of reinforced concrete (RC). Because structural deterioration due to corrosion may cause failure and large-scale disaster, various methods of measuring the corrosion rate (electrochemical methods, electrical methods, fiber optic sensors, strain gauge, ultrasonic wave, and infrared thermography) have been proposed so far. The electrochemical methods are the most widely used for estimating corrosion rates but have the limitations that the measurement results are qualitative, and are affected by climatic parameters. To overcome these limitations, fiber Bragg grating (FBG) sensors to directly detect the expansion displacement of reinforcing bars due to corrosion have been developed. However, these sensors are susceptible to strain induced by heat and external loads, and they also present challenges in terms of miniaturization and installation. This study developed a new optical sensor that can overcome the limitations of existing sensors. The developed sensor detects the expansion displacement of the sacrificial steel plate due to corrosion and thus estimates the corrosion rate of rebar. A linear relationship between the displacement and the sensor response was observed, and the sensor was capable of measuring the displacement up to half the depth of the sensor. The sensor also showed a reversible response to repeated displacement and was stable even in alkaline and salty environments. Its practicality was also verified by accelerated corrosion tests.
- 4 December 2023
- Published by Springer Nature in Research Square
Open AccessOptical Sensor for Monitoring Corrosion of Rebar in Reinforced Concrete Members Using Polydimethylsiloxane - Titanium Oxide Composite
Corrosion of reinforcing bars deteriorates the bond between the rebar and concrete, consequently leading to the degradation of the strength and stiffness of reinforced concrete (RC). Because structural deterioration due to corrosion may cause failure and large-scale disaster, various methods of measuring the corrosion rate (electrochemical methods, electrical methods, fiber optic sensors, strain gauge, ultrasonic wave, and infrared thermography) have been proposed so far. The electrochemical methods are the most widely used for estimating corrosion rates but have the limitations that the measurement results are qualitative, and are affected by climatic parameters. To overcome these limitations, fiber Bragg grating (FBG) sensors to directly detect the expansion displacement of reinforcing bars due to corrosion have been developed. However, these sensors are susceptible to strain induced by heat and external loads, and they also present challenges in terms of miniaturization and installation. This study developed a new optical sensor that can overcome the limitations of existing sensors. The developed sensor detects the expansion displacement of the sacrificial steel plate due to corrosion and thus estimates the corrosion rate of rebar. A linear relationship between the displacement and the sensor response was observed, and the sensor was capable of measuring the displacement up to half the depth of the sensor. The sensor also showed a reversible response to repeated displacement and was stable even in alkaline and salty environments. Its practicality was also verified by accelerated corrosion tests.