Gepu Guo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Gepu Guo has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- Qingyu Ma
School of Computer and Electronic Information, Nanjing Normal University, Nanjing 210023, China; Key Laboratory of Numerical Simulation for Large Scale Complex Systems, Ministry of Education, Nanjing Normal University, Nanjing 210023, China
25 shared publications - Dong Zhang
Nanjing University
15 shared publications Yuzhi Li
School of Computer and Electronic Information, Nanjing Normal University, Nanjing 210023, China
11 shared publicationsJuan Tu
Institute of Acoustics, Nanjing University, Nanjing 210093, China
10 shared publications- Juan Tu
Department of Acoustics, School of Physics, Jiangsu Key Laboratory for Cardiovascular Information and Health Engineering Medicine, Nanjing University, Nanjing 210093, China
8 shared publications Dong Zhang
Institute of Acoustics, Nanjing University, Nanjing 210093, China
6 shared publications
Latest Publications
- 20 July 2026
- Published by Elsevier in Applied Acoustics
- Vol. 254
High-resolution three-dimensional acoustic-vortex imaging with a single-input multiple-output circular array
- 20 July 2026
- Published by Elsevier in Applied Acoustics
- Vol. 254
High-resolution three-dimensional acoustic-vortex imaging with a single-input multiple-output circular array
- 1 June 2026
- Published by Elsevier in Ultrasonics
- Vol. 167, 108175
Circular orbital manipulation of positive-acoustic-contrast particles employing double-ring perfect acoustic-vortex beams
- 1 June 2026
- Published by Elsevier in Ultrasonics
- Vol. 167, 108175
Circular orbital manipulation of positive-acoustic-contrast particles employing double-ring perfect acoustic-vortex beams
- 18 September 2025
- Published by IOP Publishing in Chinese Physics B
- Vol. 35 (5)
Advanced magneto-acousto-electrical tomography based on circular arrays of omnidirectional transducers and orthogonally oriented electrodes
Magneto-acousto-electrical tomography (MAET) is a promising imaging modality capable of visualizing electrical conductivity variations in tissues. However, its imaging quality and efficiency are often compromised by the mechanical rotation and scanning processes. An advanced MAET approach that employs cyclic excitation of omnidirectional transducers and synchronous detection with orthogonally oriented electrodes is presented. The principle of MAE measurement regarding acoustic excitation and electrical detection at arbitrary positions is derived. It confirms that the signal attenuation originates from the cosine product of the angles between the conductivity boundary and the positions of the transducer and electrode. A new tomographic algorithm utilizing amplitude summation for electrode-detected signals is developed, and it is further refined through the application of square-amplitude summation for orthogonally oriented electrodes. The performance improvement is validated by accurate reconstruction of an eccentrically positioned cylindrical model, using an optimized experimental system comprising 32 sources and 4 electrodes. These promising results demonstrate that the efficiency, stability, and quality of MAET can be substantially enhanced through electrically controlled cyclic excitation and synchronous detection, thereby eliminating the need of mechanical activities. By integrating MAET with ultrasonic CT, a novel dual-modality imaging strategy that leverages both electrical and acoustic impedances can be further advanced.
- 18 September 2025
- Published by IOP Publishing in Chinese Physics B
- Vol. 35 (5)
Advanced magneto-acousto-electrical tomography based on circular arrays of omnidirectional transducers and orthogonally oriented electrodes
Magneto-acousto-electrical tomography (MAET) is a promising imaging modality capable of visualizing electrical conductivity variations in tissues. However, its imaging quality and efficiency are often compromised by the mechanical rotation and scanning processes. An advanced MAET approach that employs cyclic excitation of omnidirectional transducers and synchronous detection with orthogonally oriented electrodes is presented. The principle of MAE measurement regarding acoustic excitation and electrical detection at arbitrary positions is derived. It confirms that the signal attenuation originates from the cosine product of the angles between the conductivity boundary and the positions of the transducer and electrode. A new tomographic algorithm utilizing amplitude summation for electrode-detected signals is developed, and it is further refined through the application of square-amplitude summation for orthogonally oriented electrodes. The performance improvement is validated by accurate reconstruction of an eccentrically positioned cylindrical model, using an optimized experimental system comprising 32 sources and 4 electrodes. These promising results demonstrate that the efficiency, stability, and quality of MAET can be substantially enhanced through electrically controlled cyclic excitation and synchronous detection, thereby eliminating the need of mechanical activities. By integrating MAET with ultrasonic CT, a novel dual-modality imaging strategy that leverages both electrical and acoustic impedances can be further advanced.
- 19 June 2025
- Published by Elsevier in Ultrasonics
- Vol. 155, 107738
Stable acoustic levitation based on coaxial confocal dual-frequency focused ultrasound and vortex beams
- 19 June 2025
- Published by Elsevier in Ultrasonics
- Vol. 155, 107738
Stable acoustic levitation based on coaxial confocal dual-frequency focused ultrasound and vortex beams
- Open Access
- 17 March 2025
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 116, 107314
Synergistic sonothrombolysis based on coaxial confocal dual-frequency focused ultrasound and vortex beams
- 17 March 2025
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 116, 107314
Open AccessSynergistic sonothrombolysis based on coaxial confocal dual-frequency focused ultrasound and vortex beams
- 14 September 2024
- Published by Elsevier in Ultrasonics
- Vol. 145, 107475
Steerable ultrasonic propulsion of rigid objects based on circular pressure modulation of a focused sectorial transducer array
- 14 September 2024
- Published by Elsevier in Ultrasonics
- Vol. 145, 107475
Steerable ultrasonic propulsion of rigid objects based on circular pressure modulation of a focused sectorial transducer array
- 12 July 2024
- Published by Elsevier in Applied Acoustics
- Vol. 225
Pressure and phase characteristics of orbital angular momentum multiplexed perfect acoustic-vortexes
- 12 July 2024
- Published by Elsevier in Applied Acoustics
- Vol. 225
Pressure and phase characteristics of orbital angular momentum multiplexed perfect acoustic-vortexes
- Open Access
- 6 June 2024
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 135 (21)
Magneto-acousto-electric effects based on focused acoustic-vortex beams in a coaxial magnetic field
As an innovative neural modulation technique, the transcranial magneto-acousto-electric (MAE) stimulation (TMAES) realizes the synergistic regulation of neuronal discharge through the ultrasonic mechanical and inductive electric effects, offering significant prospects in biomedical applications. However, the stimulation accuracy is still limited by the unidirectional distribution of MAE field intensity. A method of constructing center-converging MAE field by coupling the helical wave fronts of focused acoustic-vortex (FAV) beams with a coaxial magnetic field is proposed. By describing FAVs with Laguerre–Gaussian functions, the theory of MAE field construction is derived in explicit formulae and the spatiotemporal characteristics of MAE fields in the focal region are analyzed. It is theoretically and experimentally demonstrated that the MAE field generated by the FAV of lth order is determined by those of (l − 1)th and (l + 1)th orders. The center-converging phase-rotating MAE field can only be generated by the FAV of first order, maintaining a constant peak intensity at the vortex center. Experimental distributions of MAE fields for FAVs of different orders show good agreements with numerical simulations. With the peak pressure of 0.86 MPa and the magnetic intensity of 0.3 T, the peak intensity of 62.1 mV/m reaching the electric stimulation threshold is achieved. The center-converging MAE field constructed by FAV may develop a new synergistic neural modulation scheme for TMAES with enhanced precision and flexibility while ensuring safety and efficacy, thereby exhibiting significant scientific and practical implications.
- 6 June 2024
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 135 (21)
Open AccessMagneto-acousto-electric effects based on focused acoustic-vortex beams in a coaxial magnetic field
As an innovative neural modulation technique, the transcranial magneto-acousto-electric (MAE) stimulation (TMAES) realizes the synergistic regulation of neuronal discharge through the ultrasonic mechanical and inductive electric effects, offering significant prospects in biomedical applications. However, the stimulation accuracy is still limited by the unidirectional distribution of MAE field intensity. A method of constructing center-converging MAE field by coupling the helical wave fronts of focused acoustic-vortex (FAV) beams with a coaxial magnetic field is proposed. By describing FAVs with Laguerre–Gaussian functions, the theory of MAE field construction is derived in explicit formulae and the spatiotemporal characteristics of MAE fields in the focal region are analyzed. It is theoretically and experimentally demonstrated that the MAE field generated by the FAV of lth order is determined by those of (l − 1)th and (l + 1)th orders. The center-converging phase-rotating MAE field can only be generated by the FAV of first order, maintaining a constant peak intensity at the vortex center. Experimental distributions of MAE fields for FAVs of different orders show good agreements with numerical simulations. With the peak pressure of 0.86 MPa and the magnetic intensity of 0.3 T, the peak intensity of 62.1 mV/m reaching the electric stimulation threshold is achieved. The center-converging MAE field constructed by FAV may develop a new synergistic neural modulation scheme for TMAES with enhanced precision and flexibility while ensuring safety and efficacy, thereby exhibiting significant scientific and practical implications.