Gilbert Maroun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Gilbert Maroun has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Alfredo Páez-Carpio
Department of Medical Imaging, Division of Vascular and Interventional Radiology, Sunnybrook Health Sciences Centre, University of Toronto, ON, Canada
3 shared publications - Amos Kalu
Division of Interventional Radiology, Department of Medical Imaging, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
2 shared publications - Charbel Saade
American University of Beirut Medical Center
2 shared publications - Lena Naffaa
Department of Diagnostic Radiology, American University of Beirut Medical Center, Beirut, Lebanon
2 shared publications Robyn Pugash
2 shared publicationsA. Mayat
Department of Radiology, Campbelltown Public Hospital, Sydney, Australia
1 shared publication
Latest Publications
- 27 July 2026
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 49 (9) , 1811-1824
Implementing a Trauma Hybrid Operating Room from an Interventional Radiology Perspective
- 27 July 2026
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 49 (9) , 1811-1824
Implementing a Trauma Hybrid Operating Room from an Interventional Radiology Perspective
- Open Access
- 3 February 2026
- Published by Springer Nature in CVIR Endovascular
- Vol. 9 (1) , 14
Mechanical thrombectomy for massive PE with incidental discovery of a patent foramen ovale: a case report
- 3 February 2026
- Published by Springer Nature in CVIR Endovascular
- Vol. 9 (1) , 14
Open AccessMechanical thrombectomy for massive PE with incidental discovery of a patent foramen ovale: a case report
- 13 January 2026
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 37 (4) , 107995
Contralateral Suppression Index as a Surrogate Marker for Aldosterone Lateralization in Simulated Incomplete Adrenal Vein Sampling
- 13 January 2026
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 37 (4) , 107995
Contralateral Suppression Index as a Surrogate Marker for Aldosterone Lateralization in Simulated Incomplete Adrenal Vein Sampling
- Open Access
- 7 October 2025
- Published by Radcliffe Medical Media Ltd in Interventional Cardiology: Reviews, Research, Resources
- Vol. 20
Importance of Pulmonary Embolism Anatomy in Ventilatory Distress and Haemodynamics
Pulmonary embolism (PE) is a leading cause of morbidity and mortality, with clinical outcomes strongly influenced by the anatomical distribution of emboli. This review explores the impact of PE anatomy on ventilatory distress and haemodynamics, emphasising the distinction between proximal and distal emboli. Proximal emboli, located in the main or lobar pulmonary arteries, significantly impairing pulmonary flow, increase pulmonary artery pressure and cause severe right ventricular dysfunction, necessitating prompt intervention. Distal emboli, while less severe, still pose risks, especially in patients with cardiopulmonary comorbidities, potentially leading to localised ventilation–perfusion mismatch and hypoxaemia. Therapeutic approaches vary by clinical status and embolus location, with systemic thrombolysis or catheter-directed therapy preferred for unstable patients with usually proximal PE, while anticoagulation suffices in stable cases, most of which involve distal emboli. Understanding PE anatomy and its relationship with PE haemodynamic and ventilatory failure is critical for risk stratification, treatment guidance and improvement of patient outcomes.
- 7 October 2025
- Published by Radcliffe Medical Media Ltd in Interventional Cardiology: Reviews, Research, Resources
- Vol. 20
Open AccessImportance of Pulmonary Embolism Anatomy in Ventilatory Distress and Haemodynamics
Pulmonary embolism (PE) is a leading cause of morbidity and mortality, with clinical outcomes strongly influenced by the anatomical distribution of emboli. This review explores the impact of PE anatomy on ventilatory distress and haemodynamics, emphasising the distinction between proximal and distal emboli. Proximal emboli, located in the main or lobar pulmonary arteries, significantly impairing pulmonary flow, increase pulmonary artery pressure and cause severe right ventricular dysfunction, necessitating prompt intervention. Distal emboli, while less severe, still pose risks, especially in patients with cardiopulmonary comorbidities, potentially leading to localised ventilation–perfusion mismatch and hypoxaemia. Therapeutic approaches vary by clinical status and embolus location, with systemic thrombolysis or catheter-directed therapy preferred for unstable patients with usually proximal PE, while anticoagulation suffices in stable cases, most of which involve distal emboli. Understanding PE anatomy and its relationship with PE haemodynamic and ventilatory failure is critical for risk stratification, treatment guidance and improvement of patient outcomes.
- Open Access
- 26 May 2025
- Published by SAGE Publications in Canadian Association of Radiologists Journal
- Vol. 77 (1) , 187-194
Computed Tomography Angiography Utilization in Lower Extremity Trauma: Insights From a Canadian Level I Trauma Centre
Introduction: Computed tomography angiography (CTA) plays an important role in assessing patients with suspected lower extremity traumatic vascular injury. However, CTA overutilization has been reported in some centres, and improper use has been linked to increased healthcare costs and prolonged Emergency Department wait times. This study evaluated CTA utilization in a Canadian Level I trauma centre, determined the rate of positive CTA studies requiring intervention, and identified factors that may reduce unnecessary examinations. Methods and Materials: This retrospective study included trauma patients who underwent lower extremity CTA between January 2020 and September 2024. Data regarding patient demographics, mechanism of injury, physical exam and computed tomography findings, ankle-brachial index value, and interventions were collected and evaluated. Statistical analysis included descriptive statistics and chi-square or Fisher’s exact tests for categorical associations. Results: Six hundred twelve patients (82% male, median age 32 years) were included. Forty-six percent had a normal physical exam, and CTA was positive in 27% of cases. Eight percent of patients required an intervention, all of whom had at least one hard sign of vascular injury. A statistically significant association was identified between hard signs of a vascular injury and positive CTA findings ( P < .001) and major vascular injuries ( P < .01). No patients with a normal physical exam and a positive CTA required intervention. Conclusion: Nearly half of the CTA studies were performed on patients with a normal physical exam, none requiring intervention. Our findings suggest that implementing institution-specific appropriate criteria may reduce unnecessary CTA studies.
- 26 May 2025
- Published by SAGE Publications in Canadian Association of Radiologists Journal
- Vol. 77 (1) , 187-194
Open AccessComputed Tomography Angiography Utilization in Lower Extremity Trauma: Insights From a Canadian Level I Trauma Centre
Introduction: Computed tomography angiography (CTA) plays an important role in assessing patients with suspected lower extremity traumatic vascular injury. However, CTA overutilization has been reported in some centres, and improper use has been linked to increased healthcare costs and prolonged Emergency Department wait times. This study evaluated CTA utilization in a Canadian Level I trauma centre, determined the rate of positive CTA studies requiring intervention, and identified factors that may reduce unnecessary examinations. Methods and Materials: This retrospective study included trauma patients who underwent lower extremity CTA between January 2020 and September 2024. Data regarding patient demographics, mechanism of injury, physical exam and computed tomography findings, ankle-brachial index value, and interventions were collected and evaluated. Statistical analysis included descriptive statistics and chi-square or Fisher’s exact tests for categorical associations. Results: Six hundred twelve patients (82% male, median age 32 years) were included. Forty-six percent had a normal physical exam, and CTA was positive in 27% of cases. Eight percent of patients required an intervention, all of whom had at least one hard sign of vascular injury. A statistically significant association was identified between hard signs of a vascular injury and positive CTA findings ( P < .001) and major vascular injuries ( P < .01). No patients with a normal physical exam and a positive CTA required intervention. Conclusion: Nearly half of the CTA studies were performed on patients with a normal physical exam, none requiring intervention. Our findings suggest that implementing institution-specific appropriate criteria may reduce unnecessary CTA studies.
- 20 March 2019
- Published by Taylor & Francis in Baylor University Medical Center Proceedings
- Vol. 32 (2) , 237-239
PHACES syndrome with ectopia cordis and hemihypertrophy
PHACES is the acronym describing the phenotypic association of posterior fossa anomalies, facial hemangioma, cardiac and eye anomalies, and sternal defects. To date, more than 300 cases of PHACE(S) have been reported. We present the case of a newborn girl who was born with a variant of the PHACES syndrome. Although the sternal cleft and the small facial hemangioma were evident clinically at birth, magnetic resonance imaging of the brain provided additional information to establish the diagnosis. In addition, the patient manifested later with hemihypertrophy, an association that has not been described previously.
- 20 March 2019
- Published by Taylor & Francis in Baylor University Medical Center Proceedings
- Vol. 32 (2) , 237-239
PHACES syndrome with ectopia cordis and hemihypertrophy
PHACES is the acronym describing the phenotypic association of posterior fossa anomalies, facial hemangioma, cardiac and eye anomalies, and sternal defects. To date, more than 300 cases of PHACE(S) have been reported. We present the case of a newborn girl who was born with a variant of the PHACES syndrome. Although the sternal cleft and the small facial hemangioma were evident clinically at birth, magnetic resonance imaging of the brain provided additional information to establish the diagnosis. In addition, the patient manifested later with hemihypertrophy, an association that has not been described previously.
- 1 September 2017
- Published by Elsevier in Clinical Radiology
- Vol. 72 (9) , 797.e11-797.e16
Increased image quality and reduced radiation dose and contrast media volume: a holistic approach to intracranial CTA
- 1 September 2017
- Published by Elsevier in Clinical Radiology
- Vol. 72 (9) , 797.e11-797.e16
Increased image quality and reduced radiation dose and contrast media volume: a holistic approach to intracranial CTA
- 1 January 2016
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 40 (6) , 964-970
256 Slice Multi-detector Computed Tomography Thoracic Aorta Computed Tomography Angiography
Caudocranial scan direction and contrast injection timing based on measured patient vessel dynamics can significantly improve arterial and aneurysmal opacification and reduce both contrast and radiation dose in the assessment of thoracic aortic aneurysms (TAA) using helical thoracic computed tomography angiography (CTA). To investigate opacification of the thoracic aorta and TAA using a caudocranial scan direction and a patient-specific contrast protocol. Thoracic aortic CTA was performed in 160 consecutive patients with suspected TAA using a 256-slice computed tomography scanner and a dual barrel contrast injector. Patients were subjected in equal numbers to one of two contrast protocols. Patient age and sex were equally distributed across both groups. Protocol A, the department's standard protocol, consisted of a craniocaudal scan direction with 100 mL of contrast, intravenously injected at a flow rate of 4.5 mL/s. Protocol B involved a caudocranial scan direction and a novel contrast formula based on patient cardiovascular dynamics, followed by 100 mL of saline at 4.5 mL/s. Each scan acquisition comprised of 120 kVp, 200 mA with modulation, temporal resolution 0.27 seconds, and pitch 0.889:1. The dose length product was measured between each protocol and data generated were compared using Mann-Whitney U nonparametric statistics. Receiver operating characteristic analysis, visual grading characteristic (VGC), and κ analyses were performed. Mean opacification in the thoracic aorta and aneurysm measured was 24 % and 55%, respectively. The mean contrast volume was significantly lower in protocol B (73 ± 10 mL) compared with A (100 ± 1 mL) (P<0.001). The contrast-to-noise ratio demonstrated significant differences between the protocols (protocol A, 18.2 ± 12.9; protocol B, 29.7 ± 0.61; P < 0.003). Mean effective dose in protocol B (2.6 ± 0.4 mSv) was reduced by 19% compared with A (3.2 ± 0.8 mSv) (P < 0.004). Aneurysmal detectability demonstrated significant increases by receiver operating characteristic and visual grading characteristic analysis for protocol B compared with A (P < 0.02), and reader agreement increased from poor to excellent. Significant increase in the visualization of TAAs following a caudocranial scan direction during helical thoracic CTA can be achieved using low-contrast volume based on patient-specific contrast formula.
- 1 January 2016
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 40 (6) , 964-970
256 Slice Multi-detector Computed Tomography Thoracic Aorta Computed Tomography Angiography
Caudocranial scan direction and contrast injection timing based on measured patient vessel dynamics can significantly improve arterial and aneurysmal opacification and reduce both contrast and radiation dose in the assessment of thoracic aortic aneurysms (TAA) using helical thoracic computed tomography angiography (CTA). To investigate opacification of the thoracic aorta and TAA using a caudocranial scan direction and a patient-specific contrast protocol. Thoracic aortic CTA was performed in 160 consecutive patients with suspected TAA using a 256-slice computed tomography scanner and a dual barrel contrast injector. Patients were subjected in equal numbers to one of two contrast protocols. Patient age and sex were equally distributed across both groups. Protocol A, the department's standard protocol, consisted of a craniocaudal scan direction with 100 mL of contrast, intravenously injected at a flow rate of 4.5 mL/s. Protocol B involved a caudocranial scan direction and a novel contrast formula based on patient cardiovascular dynamics, followed by 100 mL of saline at 4.5 mL/s. Each scan acquisition comprised of 120 kVp, 200 mA with modulation, temporal resolution 0.27 seconds, and pitch 0.889:1. The dose length product was measured between each protocol and data generated were compared using Mann-Whitney U nonparametric statistics. Receiver operating characteristic analysis, visual grading characteristic (VGC), and κ analyses were performed. Mean opacification in the thoracic aorta and aneurysm measured was 24 % and 55%, respectively. The mean contrast volume was significantly lower in protocol B (73 ± 10 mL) compared with A (100 ± 1 mL) (P<0.001). The contrast-to-noise ratio demonstrated significant differences between the protocols (protocol A, 18.2 ± 12.9; protocol B, 29.7 ± 0.61; P < 0.003). Mean effective dose in protocol B (2.6 ± 0.4 mSv) was reduced by 19% compared with A (3.2 ± 0.8 mSv) (P < 0.004). Aneurysmal detectability demonstrated significant increases by receiver operating characteristic and visual grading characteristic analysis for protocol B compared with A (P < 0.02), and reader agreement increased from poor to excellent. Significant increase in the visualization of TAAs following a caudocranial scan direction during helical thoracic CTA can be achieved using low-contrast volume based on patient-specific contrast formula.