Rani Bakkour
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Rani Bakkour has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
- Martin Elsner
Chair of Analytical Chemistry and Water Chemistry TUM School of Natural Sciences Technical University of Munich Garching Germany
9 shared publications - Christopher Wabnitz
Department of Chemistry, Chair of Analytical Chemistry and Water Chemistry, TUM School of Natural Sciences, Technical University of Munich, Lichtenbergstr. 4, 85748 Garching, Germany
3 shared publications - David Glöckler
TUM School of Natural Sciences, Chair of Analytical Chemistry and Water Chemistry, Technical University of Munich, Garching 85748 , Germany
3 shared publications Christopher Wabnitz
2 shared publicationsMourad Harir
Research Unit Analytical BioGeoChemistry, Helmholtz Munich, Neuherberg 85764, Germany
2 shared publicationsPhilippe Schmitt-Kopplin
Research Unit Analytical BioGeoChemistry, Helmholtz Munich, Neuherberg 85764, Germany
2 shared publications
Latest Publications
- Open Access
- 31 January 2025
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 417 (8) , 1663-1675
Role of membrane porosity in passive sampling of aquatic contaminants for stable isotope analysis: enhancement of analyte accumulation rates and selectivity
Compound-specific isotope analysis (CSIA) is a potent method for illustrating the in situ degradation of aquatic contaminants. However, its application to surface and groundwater is hindered by low contaminant concentrations, typically in the nanogram-per-litre range, requiring the processing of large water volumes. Polar organic chemical integrative samplers (POCIS) have shown promising results when combined with CSIA, yet their extended deployment time to accumulate sufficient analyte mass remains a major limitation. In our study, we addressed this issue by increasing the pore size of the polyethersulfone membrane (PES) from 0.1 to 8 $$\upmu $$ m. This resulted in significant increases in the mass accumulation rates of atrazine (3.5-fold), S-metolachlor (3.4-fold), and boscalid (3.0-fold). Importantly, the larger pore sizes did not compromise isotopic integrity, with $$\Delta \delta ^{13}$$ C $$\le +0.4\pm 0.1$$ ‰ and $$\Delta \delta ^{15}$$ N $$\le -0.6\pm 0.4$$ ‰, both within accepted uncertainties. Additionally, we observed an enhanced selectivity of the larger pores towards the target analytes over humic acids, whereas no significant increase in (bio)fouling potential was detected for the 8 $$\upmu $$ m membrane, as demonstrated by gravimetric analysis, SEM measurements, mass accumulation rates, and isotope ratios of fouled and unfouled POCIS. Our findings show that increasing the membrane pore size from 0.1 to 8 $$\upmu $$ m reduces deployment time and expedites the accumulation of analyte mass required for gas chromatography isotope ratio mass spectrometry, offering a promising method to expand CSIA for low-concentration pesticide analysis in the field. Graphical- 31 January 2025
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 417 (8) , 1663-1675
Open AccessRole of membrane porosity in passive sampling of aquatic contaminants for stable isotope analysis: enhancement of analyte accumulation rates and selectivity
Compound-specific isotope analysis (CSIA) is a potent method for illustrating the in situ degradation of aquatic contaminants. However, its application to surface and groundwater is hindered by low contaminant concentrations, typically in the nanogram-per-litre range, requiring the processing of large water volumes. Polar organic chemical integrative samplers (POCIS) have shown promising results when combined with CSIA, yet their extended deployment time to accumulate sufficient analyte mass remains a major limitation. In our study, we addressed this issue by increasing the pore size of the polyethersulfone membrane (PES) from 0.1 to 8 $$\upmu $$ m. This resulted in significant increases in the mass accumulation rates of atrazine (3.5-fold), S-metolachlor (3.4-fold), and boscalid (3.0-fold). Importantly, the larger pore sizes did not compromise isotopic integrity, with $$\Delta \delta ^{13}$$ C $$\le +0.4\pm 0.1$$ ‰ and $$\Delta \delta ^{15}$$ N $$\le -0.6\pm 0.4$$ ‰, both within accepted uncertainties. Additionally, we observed an enhanced selectivity of the larger pores towards the target analytes over humic acids, whereas no significant increase in (bio)fouling potential was detected for the 8 $$\upmu $$ m membrane, as demonstrated by gravimetric analysis, SEM measurements, mass accumulation rates, and isotope ratios of fouled and unfouled POCIS. Our findings show that increasing the membrane pore size from 0.1 to 8 $$\upmu $$ m reduces deployment time and expedites the accumulation of analyte mass required for gas chromatography isotope ratio mass spectrometry, offering a promising method to expand CSIA for low-concentration pesticide analysis in the field. Graphical - Open Access
- 12 August 2024
- Published by Elsevier in TrAC Trends in Analytical Chemistry
- Vol. 180
Lack of selectivity in sample preparation ‒ An achilles heel of compound-specific isotope analysis for environmental micropollutants
- 12 August 2024
- Published by Elsevier in TrAC Trends in Analytical Chemistry
- Vol. 180
Open AccessLack of selectivity in sample preparation ‒ An achilles heel of compound-specific isotope analysis for environmental micropollutants
- Open Access
- 3 May 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (19) , 7436-7443
Quartz Crystal Microbalance as a Holistic Detector for Quantifying Complex Organic Matrices during Liquid Chromatography: 2. Compound-Specific Isotope Analysis
In carbon-compound-specific isotope analysis (carbon CSIA) of environmental micropollutants, purification of samples is often required to guarantee accurate measurements of a target compound. A companion paper has brought forward an innovative approach to couple a quartz crystal microbalance (QCM) with high-performance liquid chromatography (HPLC) for the online quantification of matrices during a gradient HPLC purification. This work investigates the benefit for isotope analysis of polar micropollutants typically present in environmental samples. Here, we studied the impact of the natural organic matter (NOM) on the isotopic integrity of model analytes and the suitability of the NOM-to-analyte ratio as a proxy for the sample purity. We further investigated limitations and enhancement of HPLC purification using QCM on C-18 and C-8 phases for single and multiple targets. Strong isotopic shifts of up to 3.3% toward the isotopic signature of NOM were observed for samples with an NOM-to-analyte ratio >= 10. Thanks to QCM, optimization of matrix removal of up to 99.8% of NOM was possible for late-eluting compounds. The efficiency of HPLC purification deteriorated when aiming for simultaneous purification of two or three compounds, leading to up to 2.5% less NOM removal. Our results suggest that one optimized HPLC purification can be achieved through systematic screening of 3 to 5 different gradients, thereby leading to a shift of the boundaries of accurate carbon CSIA by up to 2 orders of magnitude toward lower micropollutant concentrations.
- 3 May 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (19) , 7436-7443
Open AccessQuartz Crystal Microbalance as a Holistic Detector for Quantifying Complex Organic Matrices during Liquid Chromatography: 2. Compound-Specific Isotope Analysis
In carbon-compound-specific isotope analysis (carbon CSIA) of environmental micropollutants, purification of samples is often required to guarantee accurate measurements of a target compound. A companion paper has brought forward an innovative approach to couple a quartz crystal microbalance (QCM) with high-performance liquid chromatography (HPLC) for the online quantification of matrices during a gradient HPLC purification. This work investigates the benefit for isotope analysis of polar micropollutants typically present in environmental samples. Here, we studied the impact of the natural organic matter (NOM) on the isotopic integrity of model analytes and the suitability of the NOM-to-analyte ratio as a proxy for the sample purity. We further investigated limitations and enhancement of HPLC purification using QCM on C-18 and C-8 phases for single and multiple targets. Strong isotopic shifts of up to 3.3% toward the isotopic signature of NOM were observed for samples with an NOM-to-analyte ratio >= 10. Thanks to QCM, optimization of matrix removal of up to 99.8% of NOM was possible for late-eluting compounds. The efficiency of HPLC purification deteriorated when aiming for simultaneous purification of two or three compounds, leading to up to 2.5% less NOM removal. Our results suggest that one optimized HPLC purification can be achieved through systematic screening of 3 to 5 different gradients, thereby leading to a shift of the boundaries of accurate carbon CSIA by up to 2 orders of magnitude toward lower micropollutant concentrations.
- Open Access
- 29 April 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (19) , 7429-7435
Quartz Crystal Microbalance as a Holistic Detector for Quantifying Complex Organic Matrices during Liquid Chromatography: 1. Coupling, Characterization, and Validation
A matrix in highly complex samples can cause adverse effects on the trace analysis of targeted organic compounds. A suitable separation of the target analyte(s) and matrix before the instrumental analysis is often a vital step for which chromatographic cleanup methods remain one of the most frequently used strategies, particularly high-performance liquid chromatography (HPLC). The lack of a simple real-time detection technique that can quantify the entirety of the matrix during this step, especially with gradient solvents, renders optimization of the cleanup challenging. This paper, along with a companion one, explores the possibilities and limitations of quartz crystal microbalance (QCM) dry-mass sensing for quantifying complex organic matrices during gradient HPLC. To this end, this work coupled a QCM and a microfluidic spray dryer with a commercial HPLC system using a flow splitter and developed a calibration and data processing strategy. The system was characterized in terms of detection and quantification limits, with LOD = 4.3-15 mg/L and LOQ = 16-52 mg/L, respectively, for different eluent compositions. Validation of natural organic matter in an environmental sample against offline total organic carbon analysis confirmed the approach's feasibility, with an absolute recovery of 103 +/- 10%. Our findings suggest that QCM dry-mass sensing could serve as a valuable tool for analysts routinely employing HPLC cleanup methods, offering potential benefits across various analytical fields.
- 29 April 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (19) , 7429-7435
Open AccessQuartz Crystal Microbalance as a Holistic Detector for Quantifying Complex Organic Matrices during Liquid Chromatography: 1. Coupling, Characterization, and Validation
A matrix in highly complex samples can cause adverse effects on the trace analysis of targeted organic compounds. A suitable separation of the target analyte(s) and matrix before the instrumental analysis is often a vital step for which chromatographic cleanup methods remain one of the most frequently used strategies, particularly high-performance liquid chromatography (HPLC). The lack of a simple real-time detection technique that can quantify the entirety of the matrix during this step, especially with gradient solvents, renders optimization of the cleanup challenging. This paper, along with a companion one, explores the possibilities and limitations of quartz crystal microbalance (QCM) dry-mass sensing for quantifying complex organic matrices during gradient HPLC. To this end, this work coupled a QCM and a microfluidic spray dryer with a commercial HPLC system using a flow splitter and developed a calibration and data processing strategy. The system was characterized in terms of detection and quantification limits, with LOD = 4.3-15 mg/L and LOQ = 16-52 mg/L, respectively, for different eluent compositions. Validation of natural organic matter in an environmental sample against offline total organic carbon analysis confirmed the approach's feasibility, with an absolute recovery of 103 +/- 10%. Our findings suggest that QCM dry-mass sensing could serve as a valuable tool for analysts routinely employing HPLC cleanup methods, offering potential benefits across various analytical fields.
- Top Cited Papers
- 17 January 2024
- Published by Springer Nature in Nature Water
- Vol. 2 (1) , 14-30
Perspectives of compound-specific isotope analysis of organic contaminants for assessing environmental fate and managing chemical pollution
- 17 January 2024
- Published by Springer Nature in Nature Water
- Vol. 2 (1) , 14-30
Top Cited PapersPerspectives of compound-specific isotope analysis of organic contaminants for assessing environmental fate and managing chemical pollution
- 13 October 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (42) , 15505-15513
Selectivity of β-Cyclodextrin Polymer toward Aquatic Contaminants: Insights from Ultrahigh-Resolution Mass Spectrometry of Dissolved Organic Matter
Selectivity in solid-phase extraction (SPE) materials has become increasingly important for analyte enrichment in sensitive analytical workflows to alleviate detrimental matrix effects. Molecular-level investigation of matrix constituents, which are preferentially extracted or excluded, can provide the analytical chemist with valuable information to learn about their control on sorbent selectivity. In this work, we employ nontargeted Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS) to elucidate the molecular chemodiversity of freshwater-derived dissolved organic matter (DOM) extracted by the selective model sorbent β-cyclodextrin polymer (β-CDP) in comparison to conventional, universal SPE sorbents (i.e., Oasis HLB, Supel-Select HLB, and LiChrolut EN). Statistical analysis of MS data corroborated the highly selective nature of β-CDP by revealing the extracted DOM spectra that are most dissimilar to original compositions. We found that its selectivity was characterized by pronounced discrimination against highly oxygenated and unsaturated DOM compounds, which were associated with the classes of lignin-like, tannin-like, and carboxylic-rich alicyclic molecules. In contrast, conventional sorbents excluded less highly oxygenated compounds and showed a more universal extraction behavior for a wide range of DOM compositional space. We lay these findings in a larger context that aids the analyst in obtaining an a priori estimate of sorbent selectivity toward any target analyte of interest serving thereby an optimization of sample preparation. This study highlights the great value of nontargeted ultrahigh-resolution MS for better understanding of targeted analytics and provides new insights into the selective sorption behavior of novel sorbents.
- 13 October 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (42) , 15505-15513
Selectivity of β-Cyclodextrin Polymer toward Aquatic Contaminants: Insights from Ultrahigh-Resolution Mass Spectrometry of Dissolved Organic Matter
Selectivity in solid-phase extraction (SPE) materials has become increasingly important for analyte enrichment in sensitive analytical workflows to alleviate detrimental matrix effects. Molecular-level investigation of matrix constituents, which are preferentially extracted or excluded, can provide the analytical chemist with valuable information to learn about their control on sorbent selectivity. In this work, we employ nontargeted Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS) to elucidate the molecular chemodiversity of freshwater-derived dissolved organic matter (DOM) extracted by the selective model sorbent β-cyclodextrin polymer (β-CDP) in comparison to conventional, universal SPE sorbents (i.e., Oasis HLB, Supel-Select HLB, and LiChrolut EN). Statistical analysis of MS data corroborated the highly selective nature of β-CDP by revealing the extracted DOM spectra that are most dissimilar to original compositions. We found that its selectivity was characterized by pronounced discrimination against highly oxygenated and unsaturated DOM compounds, which were associated with the classes of lignin-like, tannin-like, and carboxylic-rich alicyclic molecules. In contrast, conventional sorbents excluded less highly oxygenated compounds and showed a more universal extraction behavior for a wide range of DOM compositional space. We lay these findings in a larger context that aids the analyst in obtaining an a priori estimate of sorbent selectivity toward any target analyte of interest serving thereby an optimization of sample preparation. This study highlights the great value of nontargeted ultrahigh-resolution MS for better understanding of targeted analytics and provides new insights into the selective sorption behavior of novel sorbents.
- 18 September 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (39) , 14582-14591
Discriminative Behavior of Cyclodextrin Polymers against Dissolved Organic Matter: Role of Cavity Size and Sorbate Properties
Cyclodextrin polymers (CDPs) are promising next-generation adsorbents in water purification technologies. The selectivity of the polymer derivate cross-linked with tetrafluoroterephthalonitrile (TFN-CDP) for nonionic and cationic micropollutants (MPs) over dissolved organic matter (DOM) renders the adsorbent also attractive for many analytical applications. The molecular drivers of the observed selectivity are, nonetheless, not yet fully understood. To provide new insights into the sorption mechanism, we (i) synthesized TFN-CDPs with different cavity sizes (α-, β-, γ-CDP); (ii) assessed their extraction efficiencies for selected nonionic MPs in competition with different DOM size fractions (10 kDa) to test for size-selectivity; and (iii) performed nontargeted, ultrahigh resolution Fourier transform ion cyclotron resonance mass spectrometry analysis on CDP-extracted DOM compounds (<1 kDa) to probe for molecular sorbate properties governing their selective sorption. First, no evidence of size-selectivity was obtained through either the different CD cavity sizes (i) or the two independent approaches (ii) and (iii). Second, we found a dominant impact of sorbate oxygenation and polarity on the extraction of DOM and MPs, respectively, with relatively oxygen-poor/nonpolar molecules favorably retained on all α-, β-, and γ-CDP. Third, our data indicates exclusion of an anionic matrix, such as carboxylic acids, but preferential sorption of cationic nitrogen-bearing DOM, pointing at repulsive and attractive forces with the negatively charged cross-linker as a likely reason. Therefore, we ascribe TFN-CDP's selectivity to nonpolar and electrostatic interactions between MPs/DOM and the polymer building blocks. These molecular insights can further aid in the optimization of efficient and selective sorbent design for environmental and analytical applications.
- 18 September 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (39) , 14582-14591
Discriminative Behavior of Cyclodextrin Polymers against Dissolved Organic Matter: Role of Cavity Size and Sorbate Properties
Cyclodextrin polymers (CDPs) are promising next-generation adsorbents in water purification technologies. The selectivity of the polymer derivate cross-linked with tetrafluoroterephthalonitrile (TFN-CDP) for nonionic and cationic micropollutants (MPs) over dissolved organic matter (DOM) renders the adsorbent also attractive for many analytical applications. The molecular drivers of the observed selectivity are, nonetheless, not yet fully understood. To provide new insights into the sorption mechanism, we (i) synthesized TFN-CDPs with different cavity sizes (α-, β-, γ-CDP); (ii) assessed their extraction efficiencies for selected nonionic MPs in competition with different DOM size fractions (10 kDa) to test for size-selectivity; and (iii) performed nontargeted, ultrahigh resolution Fourier transform ion cyclotron resonance mass spectrometry analysis on CDP-extracted DOM compounds (<1 kDa) to probe for molecular sorbate properties governing their selective sorption. First, no evidence of size-selectivity was obtained through either the different CD cavity sizes (i) or the two independent approaches (ii) and (iii). Second, we found a dominant impact of sorbate oxygenation and polarity on the extraction of DOM and MPs, respectively, with relatively oxygen-poor/nonpolar molecules favorably retained on all α-, β-, and γ-CDP. Third, our data indicates exclusion of an anionic matrix, such as carboxylic acids, but preferential sorption of cationic nitrogen-bearing DOM, pointing at repulsive and attractive forces with the negatively charged cross-linker as a likely reason. Therefore, we ascribe TFN-CDP's selectivity to nonpolar and electrostatic interactions between MPs/DOM and the polymer building blocks. These molecular insights can further aid in the optimization of efficient and selective sorbent design for environmental and analytical applications.
- 11 May 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (20) , 7839-7848
Avoiding Interferences in Advance: Cyclodextrin Polymers to Enhance Selectivity in Extraction of Organic Micropollutants for Carbon Isotope Analysis
Compound-specific isotope analysis (CSIA) of organic water contaminants can provide important information about their sources and fate in the environment. Analyte enrichment from water remains nonetheless a critical yet inevitable step before measurement. Commercially available solid-phase extraction (SPE) sorbents are inherently nonselective leading to co-extraction of concurrent dissolved organic matter (DOM) and in turn to analytical interferences, especially for low-occurring contaminants. Here, we (i) increased extraction selectivity by synthesizing cyclodextrin polymers (α-, β-, γ-CDP) as SPE sorbents, (ii) assessed their applicability to carbon isotope analysis for a selection of pesticides, and (iii) compared them with commonly used commercial sorbents. Extraction with β-CDP significantly reduced backgrounds in gas chromatography-isotope ratio mass spectrometry (GC-IRMS) and enhanced sensitivity by a factor of 7.5, which was further confirmed by lower carbon-normalized CDOM/Canalyte ratios in corresponding extracts as derived from dissolved organic carbon (DOC) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis. Gibbs free energies of adsorption demonstrated weak competition between DOM and analyte on the three CDPs. No isotopic fractionation (Δδ13C within ± 0.3‰) was observed for the investigated pesticides after using β-CDP as an SPE sorbent covering a range of concentrations (5-500 μg L-1), flow velocities (5-40 cm min-1), and sorbent regeneration (up to six times). The present study highlights the benefit of selecting innovative extraction sorbents to avoid interferences in advance. This strategy in combination with existing cleanup approaches offers new prospects for CSIA at field concentrations of tens to hundreds of nanograms per liter.
- 11 May 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (20) , 7839-7848
Avoiding Interferences in Advance: Cyclodextrin Polymers to Enhance Selectivity in Extraction of Organic Micropollutants for Carbon Isotope Analysis
Compound-specific isotope analysis (CSIA) of organic water contaminants can provide important information about their sources and fate in the environment. Analyte enrichment from water remains nonetheless a critical yet inevitable step before measurement. Commercially available solid-phase extraction (SPE) sorbents are inherently nonselective leading to co-extraction of concurrent dissolved organic matter (DOM) and in turn to analytical interferences, especially for low-occurring contaminants. Here, we (i) increased extraction selectivity by synthesizing cyclodextrin polymers (α-, β-, γ-CDP) as SPE sorbents, (ii) assessed their applicability to carbon isotope analysis for a selection of pesticides, and (iii) compared them with commonly used commercial sorbents. Extraction with β-CDP significantly reduced backgrounds in gas chromatography-isotope ratio mass spectrometry (GC-IRMS) and enhanced sensitivity by a factor of 7.5, which was further confirmed by lower carbon-normalized CDOM/Canalyte ratios in corresponding extracts as derived from dissolved organic carbon (DOC) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis. Gibbs free energies of adsorption demonstrated weak competition between DOM and analyte on the three CDPs. No isotopic fractionation (Δδ13C within ± 0.3‰) was observed for the investigated pesticides after using β-CDP as an SPE sorbent covering a range of concentrations (5-500 μg L-1), flow velocities (5-40 cm min-1), and sorbent regeneration (up to six times). The present study highlights the benefit of selecting innovative extraction sorbents to avoid interferences in advance. This strategy in combination with existing cleanup approaches offers new prospects for CSIA at field concentrations of tens to hundreds of nanograms per liter.
- 27 March 2023
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 34 (4) , 525-537
Discovering Nature’s Fingerprints: Isotope Ratio Analysis on Bioanalytical Mass Spectrometers
For a generation or more, the mass spectrometry that developed at the frontier of molecular biology was worlds apart from isotope ratio mass spectrometry, a label-free approach done on optimized gas-source magnetic sector instruments. Recent studies show that electrospray-ionization Orbitraps and other mass spectrometers widely used in the life sciences can be fine-tuned for high-precision isotope ratio analysis. Since isotope patterns form everywhere in nature based on well-understood principles, intramolecular isotope measurements allow unique insights into a fascinating range of research topics. This Perspective introduces a wider readership to current topics in stable isotope research with the aim of discussing how soft-ionization mass spectrometry coupled with ultrahigh mass resolution can enable long-envisioned progress. We highlight novel prospects of observing isotopes in intact polar compounds and speculate on future directions of this adventure into the overlapping realms of biology, chemistry, and geology.
- 27 March 2023
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 34 (4) , 525-537
Discovering Nature’s Fingerprints: Isotope Ratio Analysis on Bioanalytical Mass Spectrometers
For a generation or more, the mass spectrometry that developed at the frontier of molecular biology was worlds apart from isotope ratio mass spectrometry, a label-free approach done on optimized gas-source magnetic sector instruments. Recent studies show that electrospray-ionization Orbitraps and other mass spectrometers widely used in the life sciences can be fine-tuned for high-precision isotope ratio analysis. Since isotope patterns form everywhere in nature based on well-understood principles, intramolecular isotope measurements allow unique insights into a fascinating range of research topics. This Perspective introduces a wider readership to current topics in stable isotope research with the aim of discussing how soft-ionization mass spectrometry coupled with ultrahigh mass resolution can enable long-envisioned progress. We highlight novel prospects of observing isotopes in intact polar compounds and speculate on future directions of this adventure into the overlapping realms of biology, chemistry, and geology.
- 22 February 2023
- Published by Elsevier in Chemosphere
- Vol. 322, 138226
Microbial hydrolysis of atrazine in contaminated groundwater
- 22 February 2023
- Published by Elsevier in Chemosphere
- Vol. 322, 138226
Microbial hydrolysis of atrazine in contaminated groundwater