MHMichael W. J. Hubbard

Michael W. J. Hubbard

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Michael W. J. Hubbard has a total of 180 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Soft X-ray Imager (SXI) on the SMILE Mission

    by S. Sembay, A. Cheney, R. Hampson, D. Agnolon, T. Arnold, A. Beardmore, A. Balado, C. Bicknell, C. Bouldin, G. Branduardi-Raymont, et al.

    The Soft X-ray Imager (SXI) is a compact X-ray telescope with a wide $15.5^{\circ } \times 26.5^{\circ }$ 15.5 ∘ × 26.5 ∘ field-of-view (FOV) and is part of the scientific payload of the Solar wind Magnetosphere Ionosphere Link Explorer (SMILE) mission. SMILE is a joint science mission between the European Space Agency (ESA) and the Chinese Academy of Sciences (CAS) and is due for launch in 2026. SXI is capable of viewing large portions of Earth’s magnetosphere from the vantage point of the SMILE orbit. SXI is designed to detect the soft X-rays from the Solar Wind Charge eXchange (SWCX) process produced when heavy ions of solar wind origin interact with neutral particles in Earth’s exosphere. SWCX provides a mechanism for boundary detection within the magnetosphere, such as the position of Earth’s magnetopause, because the solar wind heavy ions essentially do not enter regions of closed magnetic field lines. The sensitivity of the SXI is such that it can potentially track movements of the magnetopause on timescales of a few minutes and the orbit of SMILE will enable such movements to be tracked for segments lasting many hours. The SXI has a large grasp (FOV times effective area) and a CCD-based detector system with an energy resolution comparable to contemporary X-ray astrophysics missions. SXI will, therefore, acquire high precision spectra capable of discriminating the composition of many of the solar wind heavy ions within the regions of interest. SXI is led by the University of Leicester (UL) in the United Kingdom (UK) with collaborating organisations on hardware, software and science support within the UK, Europe, China and the United States.


  • Open Access

    Using the XMM-Newton small window mode to investigate systematic uncertainties in the particle background of X-ray charge-coupled device detectors

    by Gerrit Schellenberger, Ralph Kraft, Paul Nulsen, Eric D. Miller, Marshall W. Bautz, Catherine E. Grant, Dan Wilkins, Steven Allen, Silvano Molendi, David N. Burrows, et al.

    Many science goals carried by instruments of future X-ray observatories, such as the Wide Field Imager (WFI)1 – 3 onboard Athena, are driven by the detection and modeling of faint, diffuse sources, such as galaxy cluster outskirts. Although measurements with current X-ray observatories are often limited by photon statistics, observatories with large collecting areas will mostly be impacted by systematic uncertainties. As shown, e.g., by Ref. 4, the systematics of the background, especially the non-X-ray background (NXB), limit the feasibility of measurements on cluster outskirts, independent of the statistical significance of the measurement: Once the signal is below the background, longer observing times cannot make up for the level of uncertainty in the background modeling. This is not unique to cluster outskirts but applies to any faint source, such as distant black holes, or detecting the first galaxy clusters and groups, both major science drivers of Athena/WFI.1,5,6 Therefore, the level and properties of the background produced by high-energy galactic cosmic ray (GCR) particles play a crucial role in the design of future X-ray observatories.


  • SMILE Soft X-ray Imager (SXI) CCD370 proton irradiation results

    by Steve Parsons, David J. Hall, Oliver Hetherington, Thomas W. Buggey, Timothy Arnold, M. W. J. Hubbard, Andrew D. Holland

    The SMILE mission, a collaborative effort between the European Space Agency and the Chinese Academy of Sciences, seeks to enhance our comprehension of the interplay between solar phenomena and the Earth's magnetosphere-ionosphere system on a global scale. Among its instrumental arsenal is the Soft X-ray Imager (SXI), designed to capture photons generated within the 200eV to 2000eV energy spectrum through the solar wind charge exchange process. This imaging tool employs two large CCD370s, each with 4510 x 4510 18μm pitch pixels, as its focal plane. SMILE will orbit Earth in an elliptical trajectory, traversing the radiation belts approximately every 52 hours. Over the course of its anticipated 3-year mission, the CCDs onboard will endure progressive deterioration from the persistent presence of trapped and solar protons. To gauge the extent of this damage and its effect on the devices' functionality, a sequence of proton radiation campaigns is underway. The final cryogenic irradiation campaign has now been completed using a fully functioning engineering model of the SXI CCD370s that will be used in flight and irradiating up to the expected end of life total non-ionising dose. The results show that the measured parallel charge transfer inefficiency (pCTI) varies with temperature both before and after irradiation, however the trend changes from decreasing with temperature to increasing. This is thought to be due to a change in the dominant effective trap species. The impact of multiple charge injection lines and 6x6 binned frame transfer is also assessed and shows that between -130 to -100°C the pCTI, when both measures are utilized, is independent of temperature. This suggests potential for more flexible thermal controls in future missions that use similar devices.


  • CMOS image sensors for x-ray interferometry

    by Thomas W. Buggey, Michael W. J. Hubbard, Konstantin D. Stefanov, Andrew D. Holland, David J. Hall

    X-ray interferometry (XRI) was first demonstrated in the early 2000’s, and many early mission concepts followed which exploited the significant improvement in spatial resolution that XRI offered. Unfortunately, optical technology was not mature enough to meet the requirements, and the idea remained dormant. ESA’s voyage 2050 programme, in combination with optical and pointing accuracy technology developments, has reignited interest in the concept, but large technological challenges still remain to realise such a groundbreaking telescope. Given the spectral and now spatial requirements of a XRI, the next generation of detector technologies must be developed which can meet those requirements to enable such a telescope. For the proposed ESA THESEUS x-ray astronomy mission, strict requirements on instrument operating temperature (-40°C) have necessitated developments of new detectors technologies, namely CMOS image sensors (CIS). The CEI, in collaboration with Te2v, have designed, manufactured, and characterised a monolithic fully depleted CIS specifically optimised for soft x-ray astronomy. The prototype detector currently meets the THESEUS soft x-ray imager requirements and boasts a near Fano-limited energy resolution of 130eV (@5.9keV) at -40°C. Although the new technology can perform well, the specific detector requirements of XRI need to balance opposing parameters of spatial and energy resolution. This paper will outline the current performance of the CIS221-X for soft x-ray astronomy (as well as other competing technologies) and describe future plans for developing CIS to meet the challenging requirements of XRI.


  • Open Access

    Impact of particle passage and focusing from micro-pore optics for radiation damage estimates

    by Michael W. J. Hubbard, Thomas W. Buggey, David J. Hall, Charly Feldman, Jonathan Keelan, Oliver Hetherington, Steven Parsons, Timothy Arnold, Andrew D. Holland

    Space observatories utilizing micro pore optics (MPOs) have been used and are planned for several future X-ray astronomy space missions. The optical systems are designed to facilitate the focusing of incoming photons onto the focal plane of telescopes. Unfortunately, as well as having a small solid angle “open” to the sky, MPOs also have the unintentional effect of focusing high-energy particles from the space radiation environment. This causes additional radiation damage to mission-critical imaging sensors with solar energetic particles being particularly focusable. Typically, processes such as sectoral analysis are used to estimate the predicted dose to components, which is a ray tracing approach, and does not include focusing effects. We investigated focused dose estimation techniques for MPOs using Monte Carlo (MC) simulations. The focused dose contribution was compared with the unfocused contribution for the Solar wind Magnetosphere Ionosphere Link Explorer mission. The unfocused dose estimates were calculated using a traditional sectoral shielding analysis. The Monte Carlo-focused dose simulations enabled dose mapping over the image sensor to be analyzed. This revealed a relatively uniform dose across the device with some focusing artifacts present. The simulations also showed that the total ionizing dose and total non-ionizing dose decreased with depth into the sensor from the entrance window. This is key when considering that charge is often stored at varying depths in imaging devices across different technologies, for example, in front or back illuminated devices.


  • Open Access

    The CCD instrument background of the SMILE SXI

    by M. W. J. Hubbard, O. Hetherington, D. J. Hall, T. W. Buggey, S. Parsons, T. Arnold, A. Holland, C. Pagani, S. Sembay

    • SMILE will have two different instrument particle background rates depending on the radiation shutter door position being open or closed. • Closed background will be highest near solar maxima whilst open background is highest during solar minima. • Unfocussed instrument background is dominated by galactic cosmic ray protons.


  • Open Access

    Impact of impurities in shielding material on simulations of instrument background in space

    by Michael W. J. Hubbard, David Hall, Oliver Hetherington, Timothy Arnold, Andrew Holland

    A major source of background for x-ray focal plane detectors in space instrumentation aboard missions, such as Extended Roentgen Survey with an Imaging Telescope Array and Athena Wide Field Imager, is the space radiation environment. High-energy radiations from the environment interact with the spacecraft structure leading to large productions of secondary particles with energies that are detectable in the science region of interest for instrumentation. Reducing the background from these events is vital for the success of many missions. Graded-Z shielding is a common solution to help reduce the instrument background. Layers of materials with decreasing atomic numbers near detectors help reduce the background. Much of the design is determined through iterative simulations to find an optimal solution that meets the requirements for the scientific operation of the instrument. Recent results have indicated an underestimate in the instrument background from the simulations. One hypothesis has been that the simulations do not typically include the impurities in the shielding materials. The work presented investigates the association of impurities in the graded-Z materials and the instrument background spectra. Typically, impurities are not included in material definitions as they can significantly increase computational time. The impurities, percentage loading, and distribution have all been explored and evaluated for an Al-Mo-Be graded-Z shield.


  • Open Access

    Mitigating the effects of particle background on the Athena Wide-Field Imager

    by Eric D. Miller, Catherine E. Grant, Marshall W. Bautz, Silvano Molendi, Ralph Kraft, Paul Nulsen, Esra Bulbul, Steven Allen, David N. Burrows, Tanja Eraerds, et al.

    The Wide Field Imager (WFI) flying on Athena will usher in the next era of studying the hot and energetic Universe. WFI observations of faint, diffuse sources will be limited by uncertainty in the background produced by high-energy particles. These particles produce easily identified "cosmic-ray tracks" along with signals from secondary photons and electrons generated by particle interactions with the instrument. The signal from these secondaries is identical to the X-rays focused by the optics, and cannot be filtered without also eliminating these precious photons. As part of a larger effort to understand the WFI background, we here present results from a study of background-reduction techniques that exploit the spatial correlation between cosmic-ray particle tracks and secondary events. We use Geant4 simulations to generate a realistic particle background, sort this into simulated WFI frames, and process those frames in a similar way to the expected flight and ground software to produce a WFI observation containing only particle background. The technique under study, Self Anti-Coincidence or SAC, then selectively filters regions of the detector around particle tracks, turning the WFI into its own anti-coincidence detector. We show that SAC is effective at improving the systematic uncertainty for observations of faint, diffuse sources, but at the cost of statistical uncertainty due to a reduction in signal. If sufficient pixel pulse-height information is telemetered to the ground for each frame, then this technique can be applied selectively based on the science goals, providing flexibility without affecting the data quality for other science. The results presented here are relevant for any future silicon-based pixelated X-ray imaging detector, and could allow the WFI and similar instruments to probe to truly faint X-ray surface brightness.

  • Open Access

    Mitigating the effects of particle background on the Athena Wide Field Imager

    by Eric D. Miller, Catherine E. Grant, Marshall W. Bautz, Silvano Molendi, Ralph P. Kraft, Paul Nulsen, Esra Bulbul, Steven Allen, David N. Burrows, Tanja Eraerds, et al.

    The Wide Field Imager (WFI) flying on Athena will usher in the next era of studying the hot and energetic Universe. Among Athena’s ambitious science programs are observations of faint, diffuse sources limited by statistical and systematic uncertainty in the background produced by high-energy cosmic ray particles. These particles produce easily identified “cosmic-ray tracks” along with less easily identified signals produced by secondary photons or x-rays generated by particle interactions with the instrument. Such secondaries produce identical signals to the x-rays focused by the optics and cannot be filtered without also eliminating these precious photons. As part of a larger effort to estimate the level of unrejected background and mitigate its effects, we here present results from a study of background-reduction techniques that exploit the spatial correlation between cosmic-ray particle tracks and secondary events. We use Geant4 simulations to generate a realistic particle background signal, sort this into simulated WFI frames, and process those frames in a similar way to the expected flight and ground software to produce a realistic WFI observation containing only particle background. The technique under study, self-anti-coincidence (SAC), then selectively filters regions of the detector around particle tracks, turning the WFI into its own anti-coincidence detector. We show that SAC is effective at improving the systematic uncertainty for observations of faint, diffuse sources, but at the cost of statistical uncertainty due to a reduction in signal. If sufficient pixel pulse-height information is telemetered to the ground for each frame, then this technique can be applied selectively based on the science goals, providing flexibility without affecting the data quality for other science. The results presented here are relevant for any future silicon-based pixelated x-ray imaging detector and could allow the WFI and similar instruments to probe to truly faint x-ray surface brightness.