Benjamin M. Yeh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Benjamin M. Yeh has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
Fergus V. Coakley
From the Departments of *Radiology and †Surgery, University of California, San Francisco, CA
7 shared publicationsBonnie N. Joe
5 shared publicationsAliya Qayyum
4 shared publicationsAntonio C. Westphalen
From the Departments of *Radiology and †Surgery, University of California, San Francisco, CA
4 shared publicationsZhen J. Wang
Department of Radiology, University of California San Francisco, 505 Parnassus Avenue, San Francisco, CA 94143-0628, United States
4 shared publicationsRichard S. Breiman
3 shared publications
Latest Publications
- 1 November 2011
- Published by Elsevier in European Journal of Radiology
- Vol. 80 (2) , 378-386
Persistent renal enhancement after intra-arterial versus intravenous iodixanol administration
- 1 November 2011
- Published by Elsevier in European Journal of Radiology
- Vol. 80 (2) , 378-386
Persistent renal enhancement after intra-arterial versus intravenous iodixanol administration
- 1 July 2011
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 197 (1) , 28-29
Luminal Imaging in the 21st Century
- 1 July 2011
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 197 (1) , 28-29
Luminal Imaging in the 21st Century
- 1 October 2009
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 29 (6) , 1669-1688
MR Imaging and CT of the Biliary Tract
Magnetic resonance (MR) imaging and computed tomography (CT) can be useful in the diagnosis of biliary disease, with both modalities allowing detailed evaluation of the biliary tract. Careful interrogation of the images is critical, regardless of modality. The identification of dilated bile ducts necessitates evaluation for strictures or filling defects, which is best performed with thin-section imaging. Smooth, concentric short-segment strictures favor a benign cause, whereas abrupt, eccentric long-segment strictures favor a malignancy. At MR imaging, extrabiliary entities such as crossing vessels or metallic clip artifact may mimic strictures and should not be mistaken for disease. A stone is the most common biliary filling defect and may occur in the absence of dilated ducts. Stones commonly have a lamellated, geometric shape and are found in a dependent portion of the duct. Identification of bile duct wall thickening raises concern for cholangitis or malignancy. Improved diagnosis of biliary disease can be achieved with a knowledge of the benefits and limitations of modern MR and CT cholangiographic techniques, including the use of biliary-excreted contrast material and of various postprocessing techniques. Familiarity with the radiologic appearances of the duct lumen, wall, and surrounding structures is also important for accurate image interpretation. The rapidly evolving technology for both MR imaging and CT of the biliary tract will continue to present radiologists with opportunities as well as challenges.
- 1 October 2009
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 29 (6) , 1669-1688
MR Imaging and CT of the Biliary Tract
Magnetic resonance (MR) imaging and computed tomography (CT) can be useful in the diagnosis of biliary disease, with both modalities allowing detailed evaluation of the biliary tract. Careful interrogation of the images is critical, regardless of modality. The identification of dilated bile ducts necessitates evaluation for strictures or filling defects, which is best performed with thin-section imaging. Smooth, concentric short-segment strictures favor a benign cause, whereas abrupt, eccentric long-segment strictures favor a malignancy. At MR imaging, extrabiliary entities such as crossing vessels or metallic clip artifact may mimic strictures and should not be mistaken for disease. A stone is the most common biliary filling defect and may occur in the absence of dilated ducts. Stones commonly have a lamellated, geometric shape and are found in a dependent portion of the duct. Identification of bile duct wall thickening raises concern for cholangitis or malignancy. Improved diagnosis of biliary disease can be achieved with a knowledge of the benefits and limitations of modern MR and CT cholangiographic techniques, including the use of biliary-excreted contrast material and of various postprocessing techniques. Familiarity with the radiologic appearances of the duct lumen, wall, and surrounding structures is also important for accurate image interpretation. The rapidly evolving technology for both MR imaging and CT of the biliary tract will continue to present radiologists with opportunities as well as challenges.
- 1 September 2009
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 193 (3) , 732-737
Delayed Enhancement of Ascites After IV Contrast Material Administration at CT: Time Course and Clinical Correlation
OBJECTIVE. The objective of our study was to determine the prevalence and clinical predictors of delayed contrast enhancement of ascites.MATERIALS AND METHODS. In this retrospective study, 132 consecutive patients with ascites who underwent repeated abdominopelvic CT examinations performed within 7 days of each other were identified. These patients included 112 patients who received and 20 who did not receive IV contrast material at the initial CT examination. For each examination, we recorded the CT attenuation of the ascites. For the follow-up scan, the presence of delayed enhancement of ascites was defined as an increase in CT attenuation > 10 HU over baseline. The Fisher's exact test, unpaired Student's t test, and logistic regression were used to determine predictors of delayed enhancement of ascites.RESULTS. A threshold increase in the attenuation of ascites by > 10 HU or more between the initial and follow-up CT examinations occurred only when IV contrast material was given with the initial examina...
- 1 September 2009
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 193 (3) , 732-737
Delayed Enhancement of Ascites After IV Contrast Material Administration at CT: Time Course and Clinical Correlation
OBJECTIVE. The objective of our study was to determine the prevalence and clinical predictors of delayed contrast enhancement of ascites.MATERIALS AND METHODS. In this retrospective study, 132 consecutive patients with ascites who underwent repeated abdominopelvic CT examinations performed within 7 days of each other were identified. These patients included 112 patients who received and 20 who did not receive IV contrast material at the initial CT examination. For each examination, we recorded the CT attenuation of the ascites. For the follow-up scan, the presence of delayed enhancement of ascites was defined as an increase in CT attenuation > 10 HU over baseline. The Fisher's exact test, unpaired Student's t test, and logistic regression were used to determine predictors of delayed enhancement of ascites.RESULTS. A threshold increase in the attenuation of ascites by > 10 HU or more between the initial and follow-up CT examinations occurred only when IV contrast material was given with the initial examina...
- 1 July 2009
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 193 (1) , 47-54
Dual-Energy and Low-kVp CT in the Abdomen
OBJECTIVE. The purpose of this article is to discuss the influence of tube potential on CT images and explore the potential impact of dual-energy CT on imaging of the abdomen and pelvis.CONCLUSION....
- 1 July 2009
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 193 (1) , 47-54
Dual-Energy and Low-kVp CT in the Abdomen
OBJECTIVE. The purpose of this article is to discuss the influence of tube potential on CT images and explore the potential impact of dual-energy CT on imaging of the abdomen and pelvis.CONCLUSION....
- 1 November 2008
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 32 (6) , 886-889
Evaluation of the Biliary Intestinal Limb of a Roux-en-Y Choledochojejunostomy Using Computed Tomographic Cholangiography
Computed tomographic (CT) findings involving the biliary intestinal limb of a Roux-en-Y choledochojejunostomy may be ambiguous because oral agents frequently do not reflux into that limb. We describe 2 cases where antegrade biliary intestinal limb opacification by intravenous CT cholangiography in the left lateral decubitus position obviated the need for biopsy of an apparent enlarging mass in the biliary intestinal limb. We conclude that CT cholangiography may help clarify the status of a Roux-en-Y choledochojejunostomy.
- 1 November 2008
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 32 (6) , 886-889
Evaluation of the Biliary Intestinal Limb of a Roux-en-Y Choledochojejunostomy Using Computed Tomographic Cholangiography
Computed tomographic (CT) findings involving the biliary intestinal limb of a Roux-en-Y choledochojejunostomy may be ambiguous because oral agents frequently do not reflux into that limb. We describe 2 cases where antegrade biliary intestinal limb opacification by intravenous CT cholangiography in the left lateral decubitus position obviated the need for biopsy of an apparent enlarging mass in the biliary intestinal limb. We conclude that CT cholangiography may help clarify the status of a Roux-en-Y choledochojejunostomy.
- 1 October 2008
- Published by Elsevier in Journal of Pediatric Urology
- Vol. 4 (5) , 398-400
Subtle renal duplication as an unrecognized cause of childhood incontinence: Diagnosis by magnetic resonance urography
- 1 October 2008
- Published by Elsevier in Journal of Pediatric Urology
- Vol. 4 (5) , 398-400
Subtle renal duplication as an unrecognized cause of childhood incontinence: Diagnosis by magnetic resonance urography
- 1 July 2008
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 32 (4) , 529-532
Computed Tomographic Appearance of Prolene Hernia System and Polypropylene Mesh Plug Inguinal Hernia Repair
Purpose: To describe the normal postoperative computed tomographic (CT) appearance of inguinal hernia repair with the Prolene (polypropylene) Hernia System and polypropylene mesh plug. Materials and Methods: The medical records for 480 consecutive patients who underwent inguinal mesh hernioplasty were reviewed to identify posthernioplasty pelvic CT scans. The presence or absence of the appearance and size of focal inguinal findings at CT for each groin was recorded by 2 radiologists in consensus. The CT scan reports and medical records were reviewed to determine prospective interpretations of these inguinal findings. Findings: Posthernoplasty CT scans were identified in 26 patients, of whom, 20 had Prolene Hernia System (unilateral, n = 20; bilateral, n = 1) or mesh plug (unilateral, n = 5; bilateral, n = 1) repairs. These patients consisted of 23 men and 3 women with a mean age of 63 years (range, 36-89 years). For Prolene Hernia System hernioplasty patients, ipsilateral focal inguinal findings were found at CT in 21 of 22 groins. These focal findings had a mean size of 2.6 ± 0.4 by 2.0 ± 0.5 cm and were ringlike in 9, nodular in 7, and feathery in appearance in 5 groins. For mesh-plug hernioplasty, ipsilateral nodular focal inguinal findings were found in all 6 of 6 groins at CT. In 2 patients, nodular focal inguinal findings were mistaken for lymphadenopathy on the prospective CT report. Conclusion: Focal inguinal findings from mesh plug inguinal hernioplasty are common, have characteristic appearances at CT, and should not be mistaken as lymphadenopathy.
- 1 July 2008
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 32 (4) , 529-532
Computed Tomographic Appearance of Prolene Hernia System and Polypropylene Mesh Plug Inguinal Hernia Repair
Purpose: To describe the normal postoperative computed tomographic (CT) appearance of inguinal hernia repair with the Prolene (polypropylene) Hernia System and polypropylene mesh plug. Materials and Methods: The medical records for 480 consecutive patients who underwent inguinal mesh hernioplasty were reviewed to identify posthernioplasty pelvic CT scans. The presence or absence of the appearance and size of focal inguinal findings at CT for each groin was recorded by 2 radiologists in consensus. The CT scan reports and medical records were reviewed to determine prospective interpretations of these inguinal findings. Findings: Posthernoplasty CT scans were identified in 26 patients, of whom, 20 had Prolene Hernia System (unilateral, n = 20; bilateral, n = 1) or mesh plug (unilateral, n = 5; bilateral, n = 1) repairs. These patients consisted of 23 men and 3 women with a mean age of 63 years (range, 36-89 years). For Prolene Hernia System hernioplasty patients, ipsilateral focal inguinal findings were found at CT in 21 of 22 groins. These focal findings had a mean size of 2.6 ± 0.4 by 2.0 ± 0.5 cm and were ringlike in 9, nodular in 7, and feathery in appearance in 5 groins. For mesh-plug hernioplasty, ipsilateral nodular focal inguinal findings were found in all 6 of 6 groins at CT. In 2 patients, nodular focal inguinal findings were mistaken for lymphadenopathy on the prospective CT report. Conclusion: Focal inguinal findings from mesh plug inguinal hernioplasty are common, have characteristic appearances at CT, and should not be mistaken as lymphadenopathy.
- 1 June 2008
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 247 (3) , 595-596
Is Assessing Renal Oxygenation by Using Blood Oxygen Level–Dependent MR Imaging a Clinical Reality?
- 1 June 2008
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 247 (3) , 595-596
Is Assessing Renal Oxygenation by Using Blood Oxygen Level–Dependent MR Imaging a Clinical Reality?
- 1 April 2008
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 247 (1) , 147-153
Physiology of Renal Medullary Tip Hyperattenuation at Unenhanced CT: Urinary Specific Gravity and the NaCl Concentration Gradient
Purpose: To retrospectively investigate the physiology of renal medullary tip hyperattenuation at unenhanced computed tomography (CT). Materials and Methods: This retrospective single-institution study was IRB approved and HIPAA compliant. Informed consent was waived. One hundred consecutive patients (53 women, mean age, 52 years; 47 men, mean age, 48 years; P = .39) without and 34 (11 women, mean age, 49 years; 23 men, mean age, 45 years; P = .54) with unilateral ureteral obstruction underwent contemporaneous urinalysis and unenhanced CT. At CT, bladder urine attenuation was measured and two readers recorded the presence of renal medullary tip hyperattenuation. For obstructed kidneys (n = 34), renal pelvic urine attenuation was also recorded. The presence of medullary tip hyperattenuation was correlated with urinary specific gravity. To investigate the physiologic basis of medullary tip hyperattenuation, attenuations for NaCl and urea phantoms (range, 0–2000 mosm/kg) were recorded and correlated to solute concentrations by using linear regression. Results: Patients with renal medullary tip hyperattenuation seen at CT had higher mean urinary specific gravity (1.023 and 1.022 for readers 1 and 2, respectively) than those without (1.015 and 1.016, respectively, both P < .05). The specific gravity correlated with higher urine attenuation (r = 0.40, P < .001). For the 34 patients with unilateral urinary obstruction, medullary tip hyperattenuation was less commonly seen in obstructed (two kidneys each for both readers) than nonobstructed (11 and 15 kidneys, respectively, both P < .005) kidneys and mean urine attenuation was lower in the obstructed renal pelvis (7.4 HU) than in the bladder (11.4 HU) (P < .005). Phantoms showed a 3.6-HU increase per 100-mosm/kg increase in NaCl concentration (r = 0.99, P < .001) but no change in attenuation with different urea concentrations. Conclusion: Renal medullary tip hyperattenuation at unenhanced CT reflects increased urinary specific gravity, likely related to high medullary tip NaCl concentrations. © RSNA, 2008
- 1 April 2008
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 247 (1) , 147-153
Physiology of Renal Medullary Tip Hyperattenuation at Unenhanced CT: Urinary Specific Gravity and the NaCl Concentration Gradient
Purpose: To retrospectively investigate the physiology of renal medullary tip hyperattenuation at unenhanced computed tomography (CT). Materials and Methods: This retrospective single-institution study was IRB approved and HIPAA compliant. Informed consent was waived. One hundred consecutive patients (53 women, mean age, 52 years; 47 men, mean age, 48 years; P = .39) without and 34 (11 women, mean age, 49 years; 23 men, mean age, 45 years; P = .54) with unilateral ureteral obstruction underwent contemporaneous urinalysis and unenhanced CT. At CT, bladder urine attenuation was measured and two readers recorded the presence of renal medullary tip hyperattenuation. For obstructed kidneys (n = 34), renal pelvic urine attenuation was also recorded. The presence of medullary tip hyperattenuation was correlated with urinary specific gravity. To investigate the physiologic basis of medullary tip hyperattenuation, attenuations for NaCl and urea phantoms (range, 0–2000 mosm/kg) were recorded and correlated to solute concentrations by using linear regression. Results: Patients with renal medullary tip hyperattenuation seen at CT had higher mean urinary specific gravity (1.023 and 1.022 for readers 1 and 2, respectively) than those without (1.015 and 1.016, respectively, both P < .05). The specific gravity correlated with higher urine attenuation (r = 0.40, P < .001). For the 34 patients with unilateral urinary obstruction, medullary tip hyperattenuation was less commonly seen in obstructed (two kidneys each for both readers) than nonobstructed (11 and 15 kidneys, respectively, both P < .005) kidneys and mean urine attenuation was lower in the obstructed renal pelvis (7.4 HU) than in the bladder (11.4 HU) (P < .005). Phantoms showed a 3.6-HU increase per 100-mosm/kg increase in NaCl concentration (r = 0.99, P < .001) but no change in attenuation with different urea concentrations. Conclusion: Renal medullary tip hyperattenuation at unenhanced CT reflects increased urinary specific gravity, likely related to high medullary tip NaCl concentrations. © RSNA, 2008